BACKGROUND: Incidence of pelvic ring fractures has increased over the past four decades, especially after low-impact trauma-classified as fragility fractures of the pelvis (FFP). To date, there is a lack of biomechanical evidence for the superiority of one existing fixation techniques over another. An FFP type IIc was simulated in 50 artificial pelvises, assigned to 5 study groups: Sacroiliac (SI) screw, SI screw plus supra-acetabular external fixator, SI screw plus plate, SI screw plus retrograde transpubic screw, or S1/S2 ala-ilium screws. The specimens were tested under progressively increasing cyclic loading. Axial stiffness and cycles to failure were analysed. Displacement at the fracture sites was evaluated, having been continuously captured via motion tracking. RESULTS: Fixation with SI screw plus plate and SI screw plus retrograde transpubic screw led to higher stability than the other tested techniques. The S1/S2 ala-ilium screws were more stable than the SI screw or the SI screw plus external fixator. CONCLUSIONS: In cases with displaced fractures, open reduction and plate fixation provides the highest stability, whereas in cases where minimally invasive techniques are applicable, a retrograde transpubic screw or S1/S2 ala-ilium screws can be considered as successful alternative treatment options.
BACKGROUND: Incidence of pelvic ring fractures has increased over the past four decades, especially after low-impact trauma-classified as fragility fractures of the pelvis (FFP). To date, there is a lack of biomechanical evidence for the superiority of one existing fixation techniques over another. An FFP type IIc was simulated in 50 artificial pelvises, assigned to 5 study groups: Sacroiliac (SI) screw, SI screw plus supra-acetabular external fixator, SI screw plus plate, SI screw plus retrograde transpubic screw, or S1/S2 ala-ilium screws. The specimens were tested under progressively increasing cyclic loading. Axial stiffness and cycles to failure were analysed. Displacement at the fracture sites was evaluated, having been continuously captured via motion tracking. RESULTS: Fixation with SI screw plus plate and SI screw plus retrograde transpubic screw led to higher stability than the other tested techniques. The S1/S2 ala-ilium screws were more stable than the SI screw or the SI screw plus external fixator. CONCLUSIONS: In cases with displaced fractures, open reduction and plate fixation provides the highest stability, whereas in cases where minimally invasive techniques are applicable, a retrograde transpubic screw or S1/S2 ala-ilium screws can be considered as successful alternative treatment options.
Authors: Pol M Rommens; Marcus Graafen; Charlotte Arand; Isabella Mehling; Alexander Hofmann; Daniel Wagner Journal: Injury Date: 2019-12-16 Impact factor: 2.586
Authors: Ivan Zderic; Daniel Wagner; Clemens Schopper; Moritz Lodde; Geoff Richards; Boyko Gueorguiev; Pol Rommens; Yves P Acklin Journal: J Orthop Res Date: 2020-11-05 Impact factor: 3.494
Authors: Silke Andrich; Burkhard Haastert; Elke Neuhaus; Kathrin Neidert; Werner Arend; Christian Ohmann; Jürgen Grebe; Andreas Vogt; Pascal Jungbluth; Simon Thelen; Joachim Windolf; Andrea Icks Journal: J Bone Miner Res Date: 2017-05-08 Impact factor: 6.741
Authors: Bryan W Cunningham; Stephen J Lewis; John Long; Anton E Dmitriev; Douglas A Linville; Keith H Bridwell Journal: Spine (Phila Pa 1976) Date: 2002-11-01 Impact factor: 3.468
Authors: John Elfar; Ron Martin Garcia Menorca; Jeffrey Douglas Reed; Spencer Stanbury Journal: J Am Acad Orthop Surg Date: 2014-02 Impact factor: 3.020
Authors: Moritz F Lodde; J Christoph Katthagen; Clemens O Schopper; Ivan Zderic; R Geoff Richards; Boyko Gueorguiev; Michael J Raschke; René Hartensuer Journal: Medicina (Kaunas) Date: 2021-12-16 Impact factor: 2.430
Authors: Leon Marcel Faust; Alexander Martin Keppler; Eduardo Suero; Johannes Gleich; Leonard Lisitano; Wolfgang Böcker; Carl Neuerburg; Daniel Pfeufer Journal: Eur J Trauma Emerg Surg Date: 2022-03-13 Impact factor: 2.374