Literature DB >> 12352569

Maneuvering the retrograde medullary screw in pubic ramus fractures.

Rami Mosheiff1, Meir Liebergall.   

Abstract

This report describes an improved percutaneous insertion technique of a retrograde medullary screw in pubic ramus fractures. This improved technique enables the use of a relatively thick retrograde medullary screw in difficult anatomical variations such as narrow or curved pubic ramus. Maneuvering of the retrograde medullary screw gives control of the proximal fragment and can assist in fracture reduction.

Entities:  

Mesh:

Year:  2002        PMID: 12352569     DOI: 10.1097/00005131-200209000-00009

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  9 in total

1.  Percutaneous osteosynthesis in the pelvis in cancer patients.

Authors:  Frederic Deschamps; Thierry de Baere; Antoine Hakime; Ernesto Pearson; Geoffroy Farouil; Christophe Teriitehau; Lambros Tselikas
Journal:  Eur Radiol       Date:  2015-08-30       Impact factor: 5.315

2.  Anatomical study of anterior column screw tunnels through virtual three-dimensional models of the pelvis.

Authors:  Hua Chen; Peifu Tang; Yimin Yao; Fei She; Yan Wang
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-01-11

3.  Percutaneous screw fixation assisted by hollow pedicle finder for superior pubic ramus fractures.

Authors:  Hai Wang; Gui Wu; Chun-Yong Chen; Yao-Yu Qiu; Yun Xie
Journal:  BMC Surg       Date:  2022-06-03       Impact factor: 2.030

4.  [Percutaneous internal fixation of pelvic fractures. German version].

Authors:  A J Stevenson; B Swartman; A T Bucknill
Journal:  Unfallchirurg       Date:  2016-10       Impact factor: 1.000

Review 5.  Percutaneous internal fixation of pelvic fractures.

Authors:  A J Stevenson; B Swartman; A T Bucknill
Journal:  Unfallchirurg       Date:  2017-12       Impact factor: 1.000

6.  Preliminary results of cannulated screw fixation for isolated pubic ramus fractures.

Authors:  Jasper Winkelhagen; Michel P J van den Bekerom; Hugo W Bolhuis; Mike Hogervorst
Journal:  Strategies Trauma Limb Reconstr       Date:  2012-05-01

7.  Are two retrograde 3.5 mm screws superior to one 7.3 mm screw for anterior pelvic ring fixation in bones with low bone mineral density?

Authors:  Y P Acklin; I Zderic; S Grechenig; R G Richards; P Schmitz; B Gueorguiev
Journal:  Bone Joint Res       Date:  2017-01       Impact factor: 5.853

8.  [The application of percutaneous retrograde pubic screw implantation assisted by hollow pedicle opener in treatment of pubic branch fracture].

Authors:  Hai Wang; Junjian Ye; Zhangxiong Lin; Gui Wu; Yun Xie
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2020-09-15

9.  Biomechanical Comparison of Five Fixation Techniques for Unstable Fragility Fractures of the Pelvic Ring.

Authors:  Moritz F Lodde; J Christoph Katthagen; Clemens O Schopper; Ivan Zderic; Geoff Richards; Boyko Gueorguiev; Michael J Raschke; René Hartensuer
Journal:  J Clin Med       Date:  2021-05-26       Impact factor: 4.241

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.