| Literature DB >> 34065387 |
Alberto Encarnación-Martínez1, Ignacio Catalá-Vilaplana1, Rafael Berenguer-Vidal2, Roberto Sanchis-Sanchis1,3, Borja Ochoa-Puig1, Pedro Pérez-Soriano1.
Abstract
An increase in the popularity of running can be seen over the last decades, with a large number of injuries on it. Most of the running injuries are related to impact accelerations and are due to overuse. In order to reduce the risk of injury or to improve performance and health new treadmill designs have been created, as it can be the curved non-motorized treadmill. The aim of this study was to analyse impact accelerations, spatio-temporal parameters and perceptual differences while running on curved non-motorized treadmill (cNMT) compared to motorized treadmill (MT) at different speeds. Therefore, 27 recreational runners completed two tests consisting of 10 min warm-up and three bouts of 8 min running at 2.77 m/s, 3.33 m/s and self-selected speed on cNMT and MT, previously randomised. Although the surface did not influence spatio-temporal parameters, a reduction in impact accelerations, head acceleration rate (mean effect size [ES] = 0.86), tibia peak (mean ES = 0.45) and tibia magnitude (mean ES = 0.55), was observed while running on cNMT in comparison with running on MT. Moreover, higher heart rate (HR) (mean ES = 0.51) and rating of perceived effort (RPE) (mean ES = 0.34) were found while running on cNMT. These findings demonstrated that higher intensity training and lower impact accelerations are experimented on cNMT, what can be used by trainers and athletes while planning training sessions.Entities:
Keywords: accelerometer; biomechanics; locomotion; treadmill
Year: 2021 PMID: 34065387 PMCID: PMC8160945 DOI: 10.3390/ijerph18105475
Source DB: PubMed Journal: Int J Environ Res Public Health ISSN: 1660-4601 Impact factor: 3.390
Figure 1Schematic representation of the study protocol.
Figure 2(A) Head acceleration rate (g/ms); (B) Tibial acceleration peak (g); (C) Tibia acceleration magnitude (g) at different speeds and surface. MT: motorized treadmill; cNMT: curved non-motorized treadmill. * Statistical differences (p < 0.05) between treadmills.
Parameters (mean and standard deviation) based on speed and surface.
| Parameters | Treadmill | Self-Selected (m/s) | 2.77 m/s | 3.33 m/s |
|---|---|---|---|---|
|
|
| 73.62 (15.94) † | 75.49 (19.36) †,c | 80.12 (21.2) †,b |
|
| 59.57 (15.27) | 58.09 (15.98) c | 60.61 (18.07) b | |
|
|
| 247.26 (91.91) | 257.74 (114.12) | 313.19 (119.58) |
|
| 257.63 (136.30) | 268.58 (137.32) | 307.10 (143.16) | |
|
|
| 2.64 (0.3) | 2.65 (0.28) | 2.74 (0.29) |
|
| 2.51 (0.31) | 2.47 (0.25) | 2.58 (0.30) | |
|
|
| 4.78 (0.85) †,c | 4.97 (0.83) †,c | 5.84 (1.01) †,a,b |
|
| 4.29 (1.05) c | 4.34 (1.06) c | 5.06 (1.25) a,b | |
|
|
| 2.88 (0.36) | 2.90 (0.34) | 3.07 (0.34) |
|
| 2.68 (0.37) | 2.63 (0.29) | 2.82 (0.36) | |
|
|
| 5.56 (1.18) †,c | 5.81 (1.06) † | 7.10 (1.12) †,a |
|
| 4.88 (1.28) c | 4.90 (1.24) | 5.90 (1.44) a | |
|
|
| 42.73 (9.55) | 45.14 (9.57) | 51.93 (8.16) |
|
| 38.89 (15.02) | 40.28 (14.45) | 46.71 (13.04) |
MT: motorized treadmill; cNMT: curved non-motorized treadmill. † differences between treadmills (p < 0.05); a difference with self-selected speed (p < 0.05); b difference with 2.77 m/s (p < 0.05); c difference with 3.33 m/s (p < 0.05).
Parameters (mean and standard deviation) based on speed and surface.
| Parameters | Treadmill | Self-Selected (m/s) | 2.77 m/s | 3.33 m/s |
|---|---|---|---|---|
|
|
| 1.86 (0.25) | 1.89 (0.10) | 2.19 (0.12) |
|
| 1.87 (0.21) | 1.88 (0.13) | 2.24 (0.28) | |
|
|
| 1.47 (0.07) | 1.47 (0.08) | 1.52 (0.09) |
|
| 1.51 (0.09) | 1.51 (0.09) | 1.51 (0.13) | |
|
|
| 9.63 (1.90) †,c | 9.81 (2.27) †,c | 12.44 (2.44) †,a,b |
|
| 10.46 (1.65) c | 10.54 (2.08) c | 13.42 (2.79) a,b | |
|
|
| 149.74 (17.35) †,c | 150.69 (17.11) †,c | 161.45 (16.77) †,a,b |
|
| 156.82 (17.01) c | 158.87 (15.81) c | 167.55 (17.93) a,b |
MT: motorized treadmill; cNMT: curved non-motorized treadmill; RPE: rating of perceived exertion. † differences between treadmills (p < 0.05); a differences with self-selected speed (p < 0.05); b difference with 2.77 m/s (p < 0.05); c difference with 3.33 m/s (p < 0.05).