Literature DB >> 25790087

The Reliability of Running Performance in a 5 km Time Trial on a Non-motorized Treadmill.

C J Stevens1, J Hacene1, D V Sculley2, L Taylor3, R Callister4, B Dascombe1.   

Abstract

The purpose of the study was to establish the reliability of performance and physiological responses during a self-paced 5 km running time trial on a non-motorized treadmill. 17 male runners (age: 32±13 years, height: 177±7 cm, body mass: 71±9 kg, sum of 7 skinfolds: 55±21 mm) performed familiarization then 2 separate maximal 5 km running time trials on a non-motorized treadmill. Physiological responses measured included heart rate, oxygen uptake, expired air volume, blood lactate concentration, tissue saturation index and integrated electromyography. Running time (1,522±163 s vs. 1,519±162 s for trials 1 and 2, respectively) demonstrated a low CV of 1.2% and high ICC of 0.99. All physiological variables had CVs of less than 4% and ICCs of >0.92, with the exception of blood lactate concentration (7.0±2 mmol·L(-1) vs. 6.5±1.5 mmol·L(-1) for trials 1 and 2, respectively; CV: 12%, ICC: 0.83) and the electromyography measures (CV: 8-27%, ICC: 0.71-0.91). The data demonstrate that performance time in a 5 km running time trial on a non-motorized treadmill is a highly reliable test. Most physiological responses measured across the 5 km run also demonstrated good reliability. © Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25790087     DOI: 10.1055/s-0034-1398680

Source DB:  PubMed          Journal:  Int J Sports Med        ISSN: 0172-4622            Impact factor:   3.118


  4 in total

Review 1.  Muscle Oximetry in Sports Science: A Systematic Review.

Authors:  Stephane Perrey; Marco Ferrari
Journal:  Sports Med       Date:  2018-03       Impact factor: 11.136

2.  Non-motorized Treadmill Running Is Associated with Higher Cardiometabolic Demands Compared with Overground and Motorized Treadmill Running.

Authors:  Robert B Edwards; Paul J Tofari; Stuart J Cormack; Douglas G Whyte
Journal:  Front Physiol       Date:  2017-11-14       Impact factor: 4.566

3.  Blueberry supplementation reduces the blood lactate response to running in normobaric hypoxia but has no effect on performance in recreational runners.

Authors:  Jason P Brandenburg; Luisa V Giles
Journal:  J Int Soc Sports Nutr       Date:  2021-03-30       Impact factor: 5.150

4.  Treadmill and Running Speed Effects on Acceleration Impacts: Curved Non-Motorized Treadmill vs. Conventional Motorized Treadmill.

Authors:  Alberto Encarnación-Martínez; Ignacio Catalá-Vilaplana; Rafael Berenguer-Vidal; Roberto Sanchis-Sanchis; Borja Ochoa-Puig; Pedro Pérez-Soriano
Journal:  Int J Environ Res Public Health       Date:  2021-05-20       Impact factor: 3.390

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.