Literature DB >> 19827471

The effects of speed and surface compliance on shock attenuation characteristics for male and female runners.

Janet S Dufek1, John A Mercer, Janet R Griffin.   

Abstract

The purpose of the study was to examine the effects of running speed and surface compliance on shock attenuation (SA) characteristics for male and female runners. We were also interested in identifying possible kinematic explanations, specifically, kinematics of the lower extremity at foot-ground contact, for anticipated gender differences in SA. Fourteen volunteer recreational runners (7 male, 7 female) ran at preferred and slow speeds on an adjustable bed treadmill, which simulated soft, medium, and hard surface conditions. Selected kinematic descriptors of lower extremity kinematics as well as leg and head peak impact acceleration values were obtained for 10 left leg contacts per subject-condition. Results identified significant SA values between genders across conditions and more specifically, across surfaces for females, with male runners demonstrating a similar trend. Regression modeling to predict SA by gender for surface conditions elicited unremarkable results, ranging from 30.9 to 59.9% explained variance. It appears that surface compliance does affect SA during running; however, the runner's ability to dissipate the shock wave may not be expressly explained by our definition of lower extremity kinematics at contact.

Entities:  

Mesh:

Year:  2009        PMID: 19827471     DOI: 10.1123/jab.25.3.219

Source DB:  PubMed          Journal:  J Appl Biomech        ISSN: 1065-8483            Impact factor:   1.833


  3 in total

1.  Comparison of impact accelerations between injury-resistant and recently injured recreational runners.

Authors:  Aoife Burke; Sarah Dillon; Siobhán O'Connor; Enda F Whyte; Shane Gore; Kieran A Moran
Journal:  PLoS One       Date:  2022-09-09       Impact factor: 3.752

2.  Treadmill and Running Speed Effects on Acceleration Impacts: Curved Non-Motorized Treadmill vs. Conventional Motorized Treadmill.

Authors:  Alberto Encarnación-Martínez; Ignacio Catalá-Vilaplana; Rafael Berenguer-Vidal; Roberto Sanchis-Sanchis; Borja Ochoa-Puig; Pedro Pérez-Soriano
Journal:  Int J Environ Res Public Health       Date:  2021-05-20       Impact factor: 3.390

Review 3.  Is This the Real Life, or Is This Just Laboratory? A Scoping Review of IMU-Based Running Gait Analysis.

Authors:  Lauren C Benson; Anu M Räisänen; Christian A Clermont; Reed Ferber
Journal:  Sensors (Basel)       Date:  2022-02-23       Impact factor: 3.576

  3 in total