OBJECTIVES/HYPOTHESIS: Previous studies have demonstrated that electrocochleography (ECochG) measurements made at the round window prior to cochlear implant (CI) electrode insertion can account for 47% of the variability in 6-month speech perception scores. Recent advances have made it possible to use the apical CI electrode to record intracochlear responses to acoustic stimuli. Study objectives were to determine 1) the relationship between intracochlear ECochG response amplitudes and 6-month speech perception scores and 2) to determine the relationship between behavioral auditory thresholds and ECochG threshold estimates. The hypothesis was that intracochlear ECochG response amplitudes made immediately after electrode insertion would be larger than historical controls (at the extracochlear site) and explain more variability in speech perception scores. STUDY DESIGN: Prospective case series. METHODS: Twenty-two adult CI recipients with varying degrees of low-frequency hearing had intracochlear ECochG measurements made immediately after CI electrode insertion using 110 dB SPL tone bursts. Tone bursts were centered at five octave-spaced frequencies between 125 and 2,000 Hz. RESULTS: There was no association between intracochlear ECochG response amplitudes and speech perception scores. But, the data suggest a mild to moderate relationship between preoperative behavioral audiometric testing and intraoperative ECochG threshold estimates. CONCLUSION: Performing intracochlear ECochG is highly feasible and results in larger response amplitudes, but performing ECochG before, rather than after, CI insertion may provide a more accurate assessment of a patient's speech perception potential. LEVEL OF EVIDENCE: 4 Laryngoscope, 131:E2681-E2688, 2021.
OBJECTIVES/HYPOTHESIS: Previous studies have demonstrated that electrocochleography (ECochG) measurements made at the round window prior to cochlear implant (CI) electrode insertion can account for 47% of the variability in 6-month speech perception scores. Recent advances have made it possible to use the apical CI electrode to record intracochlear responses to acoustic stimuli. Study objectives were to determine 1) the relationship between intracochlear ECochG response amplitudes and 6-month speech perception scores and 2) to determine the relationship between behavioral auditory thresholds and ECochG threshold estimates. The hypothesis was that intracochlear ECochG response amplitudes made immediately after electrode insertion would be larger than historical controls (at the extracochlear site) and explain more variability in speech perception scores. STUDY DESIGN: Prospective case series. METHODS: Twenty-two adult CI recipients with varying degrees of low-frequency hearing had intracochlear ECochG measurements made immediately after CI electrode insertion using 110 dB SPL tone bursts. Tone bursts were centered at five octave-spaced frequencies between 125 and 2,000 Hz. RESULTS: There was no association between intracochlear ECochG response amplitudes and speech perception scores. But, the data suggest a mild to moderate relationship between preoperative behavioral audiometric testing and intraoperative ECochG threshold estimates. CONCLUSION: Performing intracochlear ECochG is highly feasible and results in larger response amplitudes, but performing ECochG before, rather than after, CI insertion may provide a more accurate assessment of a patient's speech perception potential. LEVEL OF EVIDENCE: 4 Laryngoscope, 131:E2681-E2688, 2021.
Authors: Luke Campbell; Arielle Kaicer; David Sly; Claire Iseli; Benjamin Wei; Robert Briggs; Stephen O'Leary Journal: Otol Neurotol Date: 2016-04 Impact factor: 2.311
Authors: Christopher K Giardina; Tatyana E Khan; Stephen H Pulver; Oliver F Adunka; Craig A Buchman; Kevin D Brown; Harold C Pillsbury; Douglas C Fitzpatrick Journal: Ear Hear Date: 2018 Nov/Dec Impact factor: 3.570
Authors: Laura K Holden; Charles C Finley; Jill B Firszt; Timothy A Holden; Christine Brenner; Lisa G Potts; Brenda D Gotter; Sallie S Vanderhoof; Karen Mispagel; Gitry Heydebrand; Margaret W Skinner Journal: Ear Hear Date: 2013 May-Jun Impact factor: 3.570
Authors: Oliver F Adunka; Christopher K Giardina; Eric J Formeister; Baishakhi Choudhury; Craig A Buchman; Douglas C Fitzpatrick Journal: Laryngoscope Date: 2015-09-11 Impact factor: 3.325
Authors: Kanthaiah Koka; William Jason Riggs; Robert Dwyer; Jourdan Taylor Holder; Jack H Noble; Benoit M Dawant; Amanda Ortmann; Carla V Valenzuela; Jameson K Mattingly; Michael M Harris; Brendan P O'Connell; Leonid M Litvak; Oliver F Adunka; Craig Alan Buchman; Robert F Labadie Journal: Otol Neurotol Date: 2018-09 Impact factor: 2.311
Authors: Brendan P O'Connell; Jourdan T Holder; Robert T Dwyer; René H Gifford; Jack H Noble; Marc L Bennett; Alejandro Rivas; George B Wanna; David S Haynes; Robert F Labadie Journal: Front Neurosci Date: 2017-05-29 Impact factor: 4.677
Authors: Amit Walia; Matthew A Shew; Dorina Kallogjeri; Cameron C Wick; Nedim Durakovic; Shannon M Lefler; Amanda J Ortmann; Jacques A Herzog; Craig A Buchman Journal: Sci Rep Date: 2022-02-23 Impact factor: 4.379