Literature DB >> 27683978

Potentiodynamic Corrosion Testing.

Selin Munir1, Matthew H Pelletier2, William R Walsh2.   

Abstract

Different metallic materials have different polarization characteristics as dictated by the open circuit potential, breakdown potential, and passivation potential of the material. The detection of these electrochemical parameters identifies the corrosion factors of a material. A reliable and well-functioning corrosion system is required to achieve this. Corrosion of the samples was achieved via a potentiodynamic polarization technique employing a three-electrode configuration, consisting of reference, counter, and working electrodes. Prior to commencement a baseline potential is obtained. Following the stabilization of the corrosion potential (Ecorr), the applied potential is ramped at a slow rate in the positive direction relative to the reference electrode. The working electrode was a stainless steel screw. The reference electrode was a standard Ag/AgCl. The counter electrode used was a platinum mesh. Having a reliable and well-functioning in vitro corrosion system to test biomaterials provides an in-expensive technique that allows for the systematic characterization of the material by determining the breakdown potential, to further understand the material's response to corrosion. The goal of the protocol is to set up and run an in vitro potentiodynamic corrosion system to analyze pitting corrosion for small metallic medical devices.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27683978      PMCID: PMC5091994          DOI: 10.3791/54351

Source DB:  PubMed          Journal:  J Vis Exp        ISSN: 1940-087X            Impact factor:   1.355


  22 in total

Review 1.  Biological reactions to wear debris in total joint replacement.

Authors:  E Ingham; J Fisher
Journal:  Proc Inst Mech Eng H       Date:  2000       Impact factor: 1.617

2.  A multicenter retrieval study of the taper interfaces of modular hip prostheses.

Authors:  Jay R Goldberg; Jeremy L Gilbert; Joshua J Jacobs; Thomas W Bauer; Wayne Paprosky; Sue Leurgans
Journal:  Clin Orthop Relat Res       Date:  2002-08       Impact factor: 4.176

3.  Six-year results of a prospective study of metal ion levels in young patients with metal-on-metal hip resurfacings.

Authors:  J Daniel; H Ziaee; C Pradhan; D J W McMinn
Journal:  J Bone Joint Surg Br       Date:  2009-02

4.  Characterisation of the surface topography, tomography and chemistry of fretting corrosion product found on retrieved polished femoral stems.

Authors:  M Bryant; M Ward; R Farrar; R Freeman; K Brummitt; J Nolan; A Neville
Journal:  J Mech Behav Biomed Mater       Date:  2013-12-07

Review 5.  Systemic toxicity related to metal hip prostheses.

Authors:  S M Bradberry; J M Wilkinson; R E Ferner
Journal:  Clin Toxicol (Phila)       Date:  2014-08-16       Impact factor: 4.467

6.  Failed metal-on-metal hip arthroplasties: a spectrum of clinical presentations and operative findings.

Authors:  James A Browne; C Dustin Bechtold; Daniel J Berry; Arlen D Hanssen; David G Lewallen
Journal:  Clin Orthop Relat Res       Date:  2010-09       Impact factor: 4.176

7.  In vitro studies of fretting corrosion of orthopaedic materials.

Authors:  S A Brown; P J Hughes; K Merritt
Journal:  J Orthop Res       Date:  1988       Impact factor: 3.494

8.  Histological features of pseudotumor-like tissues from metal-on-metal hips.

Authors:  Pat Campbell; Edward Ebramzadeh; Scott Nelson; Karren Takamura; Koen De Smet; Harlan C Amstutz
Journal:  Clin Orthop Relat Res       Date:  2010-09       Impact factor: 4.176

9.  Adverse local tissue reaction arising from corrosion at the femoral neck-body junction in a dual-taper stem with a cobalt-chromium modular neck.

Authors:  H John Cooper; Robert M Urban; Richard L Wixson; R Michael Meneghini; Joshua J Jacobs
Journal:  J Bone Joint Surg Am       Date:  2013-05-15       Impact factor: 5.284

Review 10.  Chromium and cobalt ion concentrations in blood and serum following various types of metal-on-metal hip arthroplasties: a literature overview.

Authors:  Christopher Jantzen; Henrik L Jørgensen; Benn R Duus; Sune L Sporring; Jes B Lauritzen
Journal:  Acta Orthop       Date:  2013-04-18       Impact factor: 3.717

View more
  1 in total

1.  Corrosion Resistance of 3D Printed Ti6Al4V Gyroid Lattices with Varying Porosity.

Authors:  Rachael Sharp; Matthew H Pelletier; William R Walsh; Cambre N Kelly; Ken Gall
Journal:  Materials (Basel)       Date:  2022-07-09       Impact factor: 3.748

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.