Literature DB >> 33778501

Free-breathing Cardiorespiratory Synchronized Cine MRI for Assessment of Left and Right Ventricular Volume and Function in Sedated Children and Adolescents with Impaired Breath-holding Capacity.

Amol S Pednekar1, Siddharth Jadhav1, Cory Noel1, Prakash Masand1.   

Abstract

PURPOSE: To prospectively compare left ventricular and right ventricular volume, function, and image quality of a free-breathing (FB) cardiorespiratory synchronized balanced steady-state free precession cine MRI sequence with that of a standard of reference breath-hold (BH) technique in sedated children and adolescents who are unable to perform BHs.
MATERIALS AND METHODS: Cohort 1 included 30 patients able to perform BHs (mean age, 19 years; age range, 9-69 years). Cohort 1 underwent both BH and FB cine short-axis imaging with identical acquisition parameters. Cohort 2 included 63 patients unable to perform BHs (50 sedated patients [mean age, 9 years; age range, 4 months to 28 years], 13 unsedated patients [mean age, 21 years; age range, 8-58 years]). Cohort 2 underwent FB cine imaging in multiple views with spatiotemporal resolution equivalent to BH imaging. Comparative quantitative analysis was performed for left ventricular and right ventricular volumes in cohort 1 and for qualitative image quality scores in all patients.
RESULTS: Global left ventricular and right ventricular volumetric indexes and image quality scores were comparable between BH and FB sequences in cohort 1. FB image quality was graded as excellent (37 sequences), good (197 sequences), adequate (26 sequences), and suboptimal (three sequences) for 263 cine sequences in cohort 2. In cohort 1, de facto image acquisition time for FB (6.1 minutes ± 1.9 [standard deviation]) was comparable to the equivalent for BH (6.1 minutes ± 2.6) for a stack of 14 sections.
CONCLUSION: In cohorts of sedated children, adolescents, and young adults unable to perform BHs consistently, left ventricular and right ventricular volumes and function were comparable and image quality was noninferior between FB and standard of reference BH techniques.© RSNA, 2019. 2019 by the Radiological Society of North America, Inc.

Entities:  

Year:  2019        PMID: 33778501      PMCID: PMC7970102          DOI: 10.1148/ryct.2019180027

Source DB:  PubMed          Journal:  Radiol Cardiothorac Imaging        ISSN: 2638-6135


  26 in total

1.  On the transient phase of balanced SSFP sequences.

Authors:  Klaus Scheffler
Journal:  Magn Reson Med       Date:  2003-04       Impact factor: 4.668

Review 2.  Principles and applications of balanced SSFP techniques.

Authors:  Klaus Scheffler; Stefan Lehnhardt
Journal:  Eur Radiol       Date:  2003-08-20       Impact factor: 5.315

3.  Operator induced variability in left ventricular measurements with cardiovascular magnetic resonance is improved after training.

Authors:  Theodoros D Karamitsos; Lucy E Hudsmith; Joseph B Selvanayagam; Stefan Neubauer; Jane M Francis
Journal:  J Cardiovasc Magn Reson       Date:  2007       Impact factor: 5.364

4.  The impact of general anesthesia on child development and school performance: a population-based study.

Authors:  Francisco J Schneuer; Jason P Bentley; Andrew J Davidson; Andrew Ja Holland; Nadia Badawi; Andrew J Martin; Justin Skowno; Samantha J Lain; Natasha Nassar
Journal:  Paediatr Anaesth       Date:  2018-04-27       Impact factor: 2.556

5.  Free-breathing Sparse Sampling Cine MR Imaging with Iterative Reconstruction for the Assessment of Left Ventricular Function and Mass at 3.0 T.

Authors:  Sonja Sudarski; Thomas Henzler; Holger Haubenreisser; Christina Dösch; Michael O Zenge; Michaela Schmidt; Mariappan S Nadar; Martin Borggrefe; Stefan O Schoenberg; Theano Papavassiliu
Journal:  Radiology       Date:  2016-07-11       Impact factor: 11.105

6.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

7.  Thermoregulation during heat exposure of young children compared to their mothers.

Authors:  K Tsuzuki-Hayakawa; Y Tochihara; T Ohnaka
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1995

8.  2D free-breathing dual navigator-gated cardiac function validated against the 2D breath-hold acquisition.

Authors:  Dana C Peters; Reza Nezafat; Holger Eggers; Christian Stehning; Warren J Manning
Journal:  J Magn Reson Imaging       Date:  2008-09       Impact factor: 4.813

9.  Indications for cardiovascular magnetic resonance in children with congenital and acquired heart disease: an expert consensus paper of the Imaging Working Group of the AEPC and the Cardiovascular Magnetic Resonance Section of the EACVI.

Authors:  E R Valsangiacomo Buechel; L Grosse-Wortmann; S Fratz; J Eichhorn; S Sarikouch; G F Greil; P Beerbaum; C Bucciarelli-Ducci; B Bonello; L Sieverding; J Schwitter; W A Helbing; Maurizio Galderisi; Owen Miller; Rosa Sicari; John Rosa; Erik Thaulow; Thor Edvardsen; Konrad Brockmeier; Shakeel Qureshi; Joerg Stein
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2015-02-17       Impact factor: 6.875

10.  Free breathing whole-heart 3D CINE MRI with self-gated Cartesian trajectory.

Authors:  M Usman; B Ruijsink; M S Nazir; G Cruz; C Prieto
Journal:  Magn Reson Imaging       Date:  2016-12-26       Impact factor: 3.130

View more
  1 in total

1.  Feasibility of one breath-hold cardiovascular magnetic resonance compressed sensing cine for left ventricular strain analysis.

Authors:  Xiaorong Chen; Jiangfeng Pan; Yi Hu; Hongjie Hu; Yonghao Pan
Journal:  Front Cardiovasc Med       Date:  2022-08-12
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.