Literature DB >> 23692884

Comparison of bifocal and trifocal diffractive and refractive intraocular lenses using an optical bench.

Damien Gatinel1, Yvette Houbrechts.   

Abstract

PURPOSE: To assess the differences in optical performance of 9 multifocal IOLs using the same optical bench and to propose a possible comparison for surgeons.
SETTING: Rothschild Foundation, Paris, France.
DESIGN: Experimental study.
METHODS: Nine IOLs (Acrysof Restor +3.0 diopter [D] SN6AD1, Acrysof Restor +4.0 D SN60D3, Acrysof aspheric monofocal SN60WF, Acri.Lisa 366D, Finevision Micro F, Tecnis ZM900, and Rezoom, Diffractiva Diff-s, and Lentis Mplus +3.0 D) were tested using the same optical bench that complies with International Organization for Standardization standard 11979 requirements. The through-focus modulation transfer functions (MTFs) were compared, and the image of the United States Air Force (USAF) target was taken while each IOL was at far, intermediate, and near focal points.
RESULTS: The through-focus MTF of the trifocal IOL showed a peak in the intermediate range that was not present with monofocal and bifocal IOLs. The USAF target images showed similar resolution with all IOLs for far focal points. Diffractive IOLs showed better resolution for near focal points, and the only sharp image in the intermediate range was obtained using the trifocal IOL.
CONCLUSION: There was a significant difference in the degree of near, intermediate, and distance quality of the image with the various types of multifocal IOLs in vitro. Intermediate vision was more prominent with the trifocal IOL. FINANCIAL DISCLOSURE: Dr. Gatinel has a proprietary interest in the optical frame used (Patent WO2011092169 [A1] 2011-08-04). Dr. Houbrechts has no financial or proprietary interest in any material or method mentioned.
Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 23692884     DOI: 10.1016/j.jcrs.2013.01.048

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  46 in total

1.  In vitro optical quality comparison between the Mini WELL Ready progressive multifocal and the TECNIS Symfony.

Authors:  Alberto Domínguez-Vicent; Jose Juan Esteve-Taboada; Antonio J Del Águila-Carrasco; Teresa Ferrer-Blasco; Robert Montés-Micó
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2015-12-16       Impact factor: 3.117

2.  In vitro optical quality of monofocal aspheric toric intraocular lenses: effect of cylindrical power.

Authors:  Teresa Ferrer-Blasco; Alberto Domínguez-Vicent; Santiago García-Lázaro; María Amparo Diez; José F Alfonso; José J Esteve-Taboada
Journal:  Int Ophthalmol       Date:  2017-04-25       Impact factor: 2.031

3.  Repeatability of in-vitro optical quality measurements of intraocular lenses with a deflectometry technique effect of the toricity.

Authors:  Teresa Ferrer-Blasco; Alberto Domínguez-Vicent; Santiago García-Lázaro; María Amparo Díez-Ajenjo; José F Alfonso; José J Esteve-Taboada
Journal:  Int J Ophthalmol       Date:  2018-07-18       Impact factor: 1.779

4.  Above-average defocus curves in photopic and mesopic vision with multifocal intraocular lenses after laser assisted in situ keratomileusis.

Authors:  Joaquín Fernández; Manuel Rodríguez-Vallejo; Javier Martínez; Ana Tauste; David P Piñero
Journal:  Int J Ophthalmol       Date:  2017-10-18       Impact factor: 1.779

5.  Model of the light sword intraocular lens: in-vitro comparative studies.

Authors:  Krzysztof Petelczyc; Andrzej Kolodziejczyk; Narcyz Błocki; Anna Byszewska; Zbigniew Jaroszewicz; Karol Kakarenko; Katarzyna Kołacz; Michał Miler; Alejandro Mira-Agudelo; Walter Torres-Sepúlveda; Marek Rękas
Journal:  Biomed Opt Express       Date:  2019-12-04       Impact factor: 3.732

6.  Pre-operative simulation of post-operative multifocal vision.

Authors:  Maria Vinas; Sara Aissati; Mercedes Romero; Clara Benedi-Garcia; Nuria Garzon; Francisco Poyales; Carlos Dorronsoro; Susana Marcos
Journal:  Biomed Opt Express       Date:  2019-10-21       Impact factor: 3.732

7.  Early outcomes of vision and objective visual quality analysis after cataract surgery with trifocal intraocular lens implantation.

Authors:  Mei-Fang Chu; Na Hui; Cong-Yi Wang; Lei Yu; Bo Ma; Yan Li; Cheng Pei
Journal:  Int J Ophthalmol       Date:  2019-10-18       Impact factor: 1.779

Review 8.  Opto-Mechanical Eye Models, a Review on Human Vision Applications and Perspectives for Use in Industry.

Authors:  André Rino Amorim; Boris Bret; José M González-Méijome
Journal:  Sensors (Basel)       Date:  2022-10-10       Impact factor: 3.847

9.  Postoperative visual performance with a bifocal and trifocal diffractive intraocular lens during a 1-year follow-up.

Authors:  Peter Mojzis; Lucia Kukuckova; Katarina Majerova; Peter Ziak; David P Piñero
Journal:  Int J Ophthalmol       Date:  2017-10-18       Impact factor: 1.779

10.  Temporal multiplexing to simulate multifocal intraocular lenses: theoretical considerations.

Authors:  Vyas Akondi; Carlos Dorronsoro; Enrique Gambra; Susana Marcos
Journal:  Biomed Opt Express       Date:  2017-06-23       Impact factor: 3.732

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.