Objective and subjective visual quality after implantation of all optic zone diffractive multifocal intraocular lenses: a prospective, case-control observational study.

Tianyu Chen1, Fang Yu1, Huayou Lin1, Yinying Zhao1, Pingjun Chang1, Lei Lin1, Qi Chen1, Qian Zheng1, Yun-E Zhao1, Fan Lu1, Jin Li1.   

Abstract

BACKGROUND AND AIMS: To evaluate the objective and subjective optical quality of all optic zone diffractive multifocal intraocular lens (IOL).
METHODS: Fifty patients (50 eyes) having phacoemulsification and IOL implantation surgery were enrolled. 25 patients were implanted with all optic zone diffractive multifocal IOL and 25 patients with monofocal IOL. Objective optical quality parameters under 4 mm pupil using Optical Quality Analysis System (OQAS), subjective visual acuity (VA) at 85 cd/m2 luminance and questionnaire concerning halo and visual function were assessed.
RESULTS: The multifocal group gained similar objective optical outcomes, such as OQAS values at contrast 100%, 20%, 9%, modulation transfer function cut-off and Strehl ratio, as the monofocal group. Objective scatter index (OSI) was significantly better in the monofocal group. Distance corrected near VA, uncorrected near VA, distance corrected intermediate VA and uncorrected intermediate VA were significantly better in the multifocal group. The difference in uncorrected distance VA and best corrected distance VA between the monofocal and multifocal groups was not significant. Mild halos and glare were reported in both groups and a significant difference between the two groups was not observed; however, moderate glare and halos were reported only in the multifocal group (2/25). There was no significant difference between the two groups when visual function was compared.
CONCLUSIONS: All optic zone diffractive multifocal IOLs provided almost the same objective optical quality as monofocal IOLs did under 4 mm pupil besides good all distance visual performance, but with greater OSI, indicating that implantation provides good optical quality in daytime but with more intraocular scatter light. TRIAL REGISTRATION NUMBER: NCT02234635, post-results. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

Entities:  

Keywords:  Clinical Trial; Lens and zonules; Optics and Refraction

Mesh:

Year:  2016        PMID: 26903522     DOI: 10.1136/bjophthalmol-2015-307135

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  11 in total

1.  Agreement between subjective and predicted high and low contrast visual acuities with a double-pass system.

Authors:  Joaquín Fernández; Manuel Rodríguez-Vallejo; Javier Martínez; Noemi Burguera; David P Piñero
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2020-10-31       Impact factor: 3.117

Review 2.  Personalized aspheric intraocular lens implantation based on corneal spherical aberration: a review.

Authors:  Wei Du; Wei Lou; Qiang Wu
Journal:  Int J Ophthalmol       Date:  2019-11-18       Impact factor: 1.779

Review 3.  Refractive errors.

Authors:  Ulrich Schiefer; Christina Kraus; Peter Baumbach; Judith Ungewiß; Ralf Michels
Journal:  Dtsch Arztebl Int       Date:  2016-10-14       Impact factor: 5.594

4.  Presbyopia-Correcting Intraocular Lenses Implantation in Eyes After Corneal Refractive Laser Surgery: A Meta-Analysis and Systematic Review.

Authors:  Yang Sun; Yingying Hong; Xianfang Rong; Yinghong Ji
Journal:  Front Med (Lausanne)       Date:  2022-04-11

5.  Comparison of postoperative visual quality after SMILE and LASEK for high myopia: A 1-year outcome.

Authors:  Xiaoyu Zhu; Leilei Zou; Manrong Yu; Chen Qiu; Minjie Chen; Jinhui Dai
Journal:  PLoS One       Date:  2017-08-03       Impact factor: 3.240

Review 6.  From Presbyopia to Cataracts: A Critical Review on Dysfunctional Lens Syndrome.

Authors:  Joaquín Fernández; Manuel Rodríguez-Vallejo; Javier Martínez; Ana Tauste; David P Piñero
Journal:  J Ophthalmol       Date:  2018-06-27       Impact factor: 1.909

7.  Utility of the optical quality analysis system for decision-making in Nd: YAG laser posterior capsulotomy in patients with light posterior capsule opacity.

Authors:  Bo Lu; Weijie Zhu; Yu Fan; Dong Shi; Liwei Ma
Journal:  BMC Ophthalmol       Date:  2021-01-06       Impact factor: 2.209

8.  Visual Performance and Optical Quality after Implantation of a New Generation Monofocal Intraocular Lens.

Authors:  Kyoung Hae Kang; Mi Yeon Song; Kook Young Kim; Kyu-Yeon Hwang; Young-A Kwon; Kyungmin Koh
Journal:  Korean J Ophthalmol       Date:  2021-04-05

9.  Comparison of the visual performance between Oculentis MF30 and Tecnis ZMB00 multifocal intraocular lenses.

Authors:  Lingying Ye; Tianyu Chen; Zhixiang Hu; Qingwen Yang; Qiudong Su; Jin Li
Journal:  Ann Transl Med       Date:  2021-01

10.  Analysis of Korean Retinal Specialists' Opinions on Implanting Diffractive Multifocal Intraocular Lenses in Eyes with Underlying Retinal Diseases.

Authors:  Jung-Hwa Lee; Mingui Kong; Joon-Hong Sohn; Beom-Jin Cho; Kee-Yong Choi; Sang-Mok Lee
Journal:  J Clin Med       Date:  2022-03-26       Impact factor: 4.241

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.