[Comparison of the registration methods for the three-dimensional facial scans applied to the design of full-arch implant supported restoration].

D N Guo1, S X Pan1, M D Heng2, J Qu2, X X Wei2, Y S Zhou1.   

Abstract

OBJECTIVE: To compare the registration accuracy of three-dimensional (3D) facial scans for the design of full-arch implant supported restoration by five methods and to explore the suitable registration method.
METHODS: According to the criteria, ten patients with maxillary edentulous jaw or end-stage dentition requiring implant supported restorations were enrolled in this study. A special rim with individual feature marks reflected appropriate occlusal relationship and esthetic characteristics was made for each patient. Both 3D facial scan data of natural laughter and with opener traction to expose the teeth or occlusal rim of each patient were acquired by facial scan and input to the digital analysis software Geomagic Qualify 2012. The dataset was superimposed by five different methods: seven facial anatomical landmark points alignment, facial immobile area alignment (forehead and nasal area), facial anatomical landmark points and immobile area combining alignment, facial feature points alignment, facial and intraoral feature points alignment with the same local coordinate system. The three-dimensional deviation of the same selected area was calculated, the smaller the deviation, the higher the registration accuracy. The 3D deviation was compared among the three registration methods of facial anatomical landmark points, facial immobile area alignment and the combination of the above two methods. Friedman test was performed to analyze the difference among the three methods (α=0.05). The effect of the aid of the facial and intraoral feature points were evaluated. Paired t test were performed to analyze the difference (P<0.05).
RESULTS: The average three-dimensional deviation of the selected area after alignment with the facial anatomical landmarks was (1.501 2±0.406 1) mm, significantly larger than that of the facial immobile area best-fit alignment [(0.629 1±0.150 6) mm] and the combination of the two methods[(0.629 1±0.150 6) mm] (P < 0.001). The aid of the facial feature points could significantly reduce the deviation (t=1.001 3, P < 0.001). There was no significant statistical difference in the remaining groups.
CONCLUSION: The forehead area of the 3D facial scan can be exposed as much as possible. The establishment of facial characteristic landmark points and the use of the invariant area alignment can improve the accuracy of registration. It should be clinically feasible to apply three-dimensional facial scan to the design of full-arch implant supported restoration with the registration of the immobile area on the face especially the forehead area.

Entities:  

Keywords:  Facial landmarks; Imaging; Implant; Registration; Registration accuracy; Three-dimensional

Mesh:

Year:  2020        PMID: 33550340      PMCID: PMC7867969     

Source DB:  PubMed          Journal:  Beijing Da Xue Xue Bao Yi Xue Ban        ISSN: 1671-167X


  16 in total

1.  Comparison of facial soft tissue measurements on three-dimensional images and models obtained with different methods.

Authors:  Derya Germec-Cakan; Halil Ibrahim Canter; Burcu Nur; Tulin Arun
Journal:  J Craniofac Surg       Date:  2010-09       Impact factor: 1.046

Review 2.  Soft- and hard-tissue facial anthropometry in three dimensions: what's new.

Authors:  Chiarella Sforza; Marcio de Menezes; Virgilio Ferrario
Journal:  J Anthropol Sci       Date:  2013-07-01

3.  Comparison of the accuracy of digital stereophotogrammetry and projection moiré profilometry for three-dimensional imaging of the face.

Authors:  A Artopoulos; J A N Buytaert; J J J Dirckx; T J Coward
Journal:  Int J Oral Maxillofac Surg       Date:  2013-11-10       Impact factor: 2.789

4.  Comparison of three-dimensional scanner systems for craniomaxillofacial imaging.

Authors:  Paul G M Knoops; Caroline A A Beaumont; Alessandro Borghi; Naiara Rodriguez-Florez; Richard W F Breakey; William Rodgers; Freida Angullia; N U Owase Jeelani; Silvia Schievano; David J Dunaway
Journal:  J Plast Reconstr Aesthet Surg       Date:  2017-01-07       Impact factor: 2.740

5.  Facially generated and cephalometric guided 3D digital design for complete mouth implant rehabilitation: A clinical report.

Authors:  Christian Coachman; Marcelo Alexandre Calamita; Francis Gray Coachman; Robert Gray Coachman; Newton Sesma
Journal:  J Prosthet Dent       Date:  2016-11-09       Impact factor: 3.426

6.  Accuracy of digital technologies for the scanning of facial, skeletal, and intraoral tissues: A systematic review.

Authors:  Lauren Bohner; Diego Diaz Gamba; Marcel Hanisch; Bruno Silva Marcio; Pedro Tortamano Neto; Dalva Cruz Laganá; Newton Sesma
Journal:  J Prosthet Dent       Date:  2018-07-14       Impact factor: 3.426

7.  Accuracy and reproducibility of the DAVID SLS-2 scanner in three-dimensional facial imaging.

Authors:  Jesper Jared Secher; Tron Andre Darvann; Else Marie Pinholt
Journal:  J Craniomaxillofac Surg       Date:  2017-07-25       Impact factor: 2.078

8.  Integrating 3D facial scanning in a digital workflow to CAD/CAM design and fabricate complete dentures for immediate total mouth rehabilitation.

Authors:  Bassam Hassan; Marcus Greven; Daniel Wismeijer
Journal:  J Adv Prosthodont       Date:  2017-10-16       Impact factor: 1.904

9.  A three-dimensional photogrammetric analysis of the facial esthetics of the Miss Korea pageant contestants.

Authors:  Kab Soo Jang; Mohamed Bayome; Jae Hyun Park; Ki-Ho Park; Hong-Beom Moon; Yoon-Ah Kook
Journal:  Korean J Orthod       Date:  2017-01-25       Impact factor: 1.372

10.  Simultaneous, radiation-free registration of the dentoalveolar position and the face by combining 3D photography with a portable scanner and impression-taking.

Authors:  Lucas M Ritschl; Klaus-Dietrich Wolff; Pia Erben; Florian D Grill
Journal:  Head Face Med       Date:  2019-11-25       Impact factor: 2.151

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.