Comparison of the accuracy of digital stereophotogrammetry and projection moiré profilometry for three-dimensional imaging of the face.

A Artopoulos1, J A N Buytaert2, J J J Dirckx2, T J Coward2.   

Abstract

The aim of this study was to compare the three-dimensional (3D) imaging accuracy between a digital stereophotogrammetry device and a projection moiré profilometry setup using anatomical models in conjunction with surface matching software. Twenty-two 3D surface models of the middle third of the face derived from computed tomography (CT) scans were used to fabricate photopolymer models by rapid prototyping. These were digitized using digital stereophotogrammetry and projection moiré profilometry. The 3D surface models acquired were compared for shape differences with the original CT models using surface matching software. Global registration between each pair of corresponding models was carried out using an iterative closest point algorithm. The mean surface deviations following registration were used to calculate Bland-Altman limits of agreement between the two methods. The distributions of measured surface differences were used to calculate L-moments. Paired t-tests were carried out for hypothesis testing. Correlation between difference and mean was -0.3, and 95% limits of agreement were -0.084mm and 0.064mm. No statistically significant differences in mean measurement error (L1 moments) were observed (P=0.1882). The experimental moiré profilometry setup employed produced 3D models of facial anatomy of comparable accuracy to a widely used commercialized digital stereophotogrammetry device.
Copyright © 2013 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

Keywords:  3D surface imaging; digital stereophotogrammetry; face scanning; moiré profilometry; surface matching

Mesh:

Year:  2013        PMID: 24225265     DOI: 10.1016/j.ijom.2013.10.005

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Surg        ISSN: 0901-5027            Impact factor:   2.789


  6 in total

1.  [Comparison of the registration methods for the three-dimensional facial scans applied to the design of full-arch implant supported restoration].

Authors:  D N Guo; S X Pan; M D Heng; J Qu; X X Wei; Y S Zhou
Journal:  Beijing Da Xue Xue Bao Yi Xue Ban       Date:  2020-12-24

2.  Application of 3D Imaging-Assisted Precise Aesthetic Evaluation in Midfacial Depression Treatment.

Authors:  Zhao Jianfang; Wang Guanhuier; An Yang; Li Dong
Journal:  Aesthetic Plast Surg       Date:  2022-04-27       Impact factor: 2.326

3.  Three-Dimensional Accuracy of Facial Scan for Facial Deformities in Clinics: A New Evaluation Method for Facial Scanner Accuracy.

Authors:  Yi-Jiao Zhao; Yu-Xue Xiong; Yong Wang
Journal:  PLoS One       Date:  2017-01-05       Impact factor: 3.240

4.  Influence of Connecting Two Standalone Mobile Three-Dimensional Scanners on Accuracy Comparing with a Standard Device in Facial Scanning.

Authors:  Ali Modabber; Florian Peters; Anna Brokmeier; Evgeny Goloborodko; Alireza Ghassemi; Bernd Lethaus; Frank Hölzle; Stephan Christian Möhlhenrich
Journal:  J Oral Maxillofac Res       Date:  2016-12-28

5.  The Effect of Perioral Scan and Artificial Skin Markers on the Accuracy of Virtual Dentofacial Integration: Stereophotogrammetry Versus Smartphone Three-Dimensional Face-Scanning.

Authors:  Hang-Nga Mai; Du-Hyeong Lee
Journal:  Int J Environ Res Public Health       Date:  2020-12-30       Impact factor: 3.390

6.  Monoscopic photogrammetry to obtain 3D models by a mobile device: a method for making facial prostheses.

Authors:  Rodrigo Salazar-Gamarra; Rosemary Seelaus; Jorge Vicente Lopes da Silva; Airton Moreira da Silva; Luciano Lauria Dib
Journal:  J Otolaryngol Head Neck Surg       Date:  2016-05-25
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.