Literature DB >> 33537233

Fully Automatic Sliding Motion Compensated and Simultaneous 4D-CBCT via Bilateral Filtering.

Jun Dang1, Tao You2, Wenzheng Sun3, Hanguan Xiao4, Longhao Li1, Xiaopin Chen1, Chunhua Dai2, Ying Li1, Yanbo Song1, Tao Zhang1, Deyu Chen2.   

Abstract

PURPOSE: To incorporate the bilateral filtering into the Deformable Vector Field (DVF) based 4D-CBCT reconstruction for realizing a fully automatic sliding motion compensated 4D-CBCT.
MATERIALS AND METHODS: Initially, a motion compensated simultaneous algebraic reconstruction technique (mSART) is used to generate a high quality reference phase (e.g. 0% phase) by using all phase projections together with the initial 4D-DVFs. The initial 4D-DVF were generated via Demons registration between 0% phase and each other phase image. The 4D-DVF will then kept updating by matching the forward projection of the deformed high quality 0% phase with the measured projection of the target phase. The loss function during this optimization contains an projection intensity difference matching criterion plus a DVF smoothing constrain term. We introduce a bilateral filtering kernel into the DVF constrain term to estimate the sliding motion automatically. The bilateral filtering kernel contains three sub-kernels: 1) an spatial domain Guassian kernel; 2) an image intensity domain Guassian kernel; and 3) a DVF domain Guassian kernel. By choosing suitable kernel variances, the sliding motion can be extracted. A non-linear conjugate gradient optimizer was used. We validated the algorithm on a non-uniform rotational B-spline based cardiac-torso (NCAT) phantom and four anonymous patient data. For quantification, we used: 1) the Root-Mean-Square-Error (RMSE) together with the Maximum-Error (MaxE); 2) the Dice coefficient of the extracted lung contour from the final reconstructed images and 3) the relative reconstruction error (RE) to evaluate the algorithm's performance.
RESULTS: For NCAT phantom, the motion trajectory's RMSE/MaxE are 0.796/1.02 mm for bilateral filtering reconstruction; and 2.704/4.08 mm for original reconstruction. For patient pilot study, the 4D-Dice coefficient obtained with bilateral filtering are consistently higher than that without bilateral filtering. Meantime several image content such as the rib position, the heart edge definition, the fibrous structures all has been better corrected with bilateral filtering.
CONCLUSION: We developed a bilateral filtering based fully automatic sliding motion compensated 4D-CBCT scheme. Both digital phantom and initial patient pilot studies confirmed the improved motion estimation and image reconstruction ability. It can be used as a 4D-CBCT image guidance tool for lung SBRT treatment.
Copyright © 2021 Dang, You, Sun, Xiao, Li, Chen, Dai, Li, Song, Zhang and Chen.

Entities:  

Keywords:  4D-CBCT; bilateral filtering; deformable vector fields; simultaneous reconstruction; sliding motion

Year:  2021        PMID: 33537233      PMCID: PMC7849763          DOI: 10.3389/fonc.2020.568627

Source DB:  PubMed          Journal:  Front Oncol        ISSN: 2234-943X            Impact factor:   6.244


  17 in total

1.  Optimizing 4D cone-beam CT acquisition protocol for external beam radiotherapy.

Authors:  Tianfang Li; Lei Xing
Journal:  Int J Radiat Oncol Biol Phys       Date:  2006-12-29       Impact factor: 7.038

2.  Four-dimensional cone beam CT with adaptive gantry rotation and adaptive data sampling.

Authors:  Jun Lu; Thomas M Guerrero; Peter Munro; Andrew Jeung; Pai-Chun M Chi; Peter Balter; X Ronald Zhu; Radhe Mohan; Tinsu Pan
Journal:  Med Phys       Date:  2007-09       Impact factor: 4.071

3.  4D cone beam CT via spatiotemporal tensor framelet.

Authors:  Hao Gao; Ruijiang Li; Yuting Lin; Lei Xing
Journal:  Med Phys       Date:  2012-11       Impact factor: 4.071

4.  An implicit sliding-motion preserving regularisation via bilateral filtering for deformable image registration.

Authors:  Bartłomiej W Papież; Mattias P Heinrich; Jérome Fehrenbach; Laurent Risser; Julia A Schnabel
Journal:  Med Image Anal       Date:  2014-06-09       Impact factor: 8.545

5.  Low-dose 4D cone-beam CT via joint spatiotemporal regularization of tensor framelet and nonlocal total variation.

Authors:  Hao Han; Hao Gao; Lei Xing
Journal:  Phys Med Biol       Date:  2017-07-20       Impact factor: 3.609

6.  Simultaneous 4D-CBCT reconstruction with sliding motion constraint.

Authors:  Jun Dang; Fang-Fang Yin; Tao You; Chunhua Dai; Deyu Chen; Jing Wang
Journal:  Med Phys       Date:  2016-10       Impact factor: 4.071

7.  Cine cone beam CT reconstruction using low-rank matrix factorization: algorithm and a proof-of-principle study.

Authors:  Jian-Feng Cai; Xun Jia; Hao Gao; Steve B Jiang; Zuowei Shen; Hongkai Zhao
Journal:  IEEE Trans Med Imaging       Date:  2014-04-21       Impact factor: 10.048

8.  Implementation and evaluation of various demons deformable image registration algorithms on a GPU.

Authors:  Xuejun Gu; Hubert Pan; Yun Liang; Richard Castillo; Deshan Yang; Dongju Choi; Edward Castillo; Amitava Majumdar; Thomas Guerrero; Steve B Jiang
Journal:  Phys Med Biol       Date:  2010-01-07       Impact factor: 3.609

9.  High-quality four-dimensional cone-beam CT by deforming prior images.

Authors:  Jing Wang; Xuejun Gu
Journal:  Phys Med Biol       Date:  2012-12-21       Impact factor: 3.609

10.  Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization.

Authors:  Emil Y Sidky; Xiaochuan Pan
Journal:  Phys Med Biol       Date:  2008-08-13       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.