Literature DB >> 3351749

Comparison of the SRK II formula and other second generation formulas.

D R Sanders1, J Retzlaff, M C Kraff.   

Abstract

A simple modification of the SRK formula was developed for use with extreme axial length cases (short and long eyes) to maximize prediction accuracy in these groups. For "average" eyes (over 75% of all cases), SRK needed no modifications to maintain maximum predictive accuracy. The new, modified SRK formula (SRK II) was compared with current second generation formulas and the Binkhorst formula. The SRK II formula, while maintaining the simplicity and ease of the SRK, was comparable to and in some cases superior to the other formulas. Overall, 80.0% of 2,068 posterior chamber intraocular lenses from seven different manufacturers demonstrated less than one diopter of prediction error and only 0.5% had three or more diopters of error. In short eyes (less than 22 mm), 74.0% were corrected to within one diopter and less than 2.0% had three or more diopters of error. In long eyes (greater than or equal to 24.5 mm), 78.0% of cases demonstrated less than one diopter of error and less than 1.0% had three or more diopters of error. Although the SRK II formula is incorporated in most new A-scan units, the modifications are so simple that surgeons can take the standard SRK predictions and mentally calculate the modifications for extreme cases.

Entities:  

Mesh:

Year:  1988        PMID: 3351749     DOI: 10.1016/s0886-3350(88)80087-7

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  23 in total

1.  Calculation of the power of anterior chamber implants.

Authors:  J R Villada; P S Raj; T Akingbehin
Journal:  Br J Ophthalmol       Date:  1992-05       Impact factor: 4.638

2.  Intra-ocular lens power calculation in patients with high axial myopia before cataract surgery.

Authors:  Raouf El-Nafees; Ashraf Moawad; Hanem Kishk; Walid Gaafar
Journal:  Saudi J Ophthalmol       Date:  2010-04-04

3.  Paediatric intraocular lens implants: accuracy of lens power calculations.

Authors:  M K O'Gallagher; M A Lagan; C P Mulholland; M Parker; G McGinnity; E M McLoone
Journal:  Eye (Lond)       Date:  2016-07-29       Impact factor: 3.775

4.  SRK II formula in the calculation of intraocular lens power.

Authors:  M S Dang; P P Raj
Journal:  Br J Ophthalmol       Date:  1989-10       Impact factor: 4.638

Review 5.  Optimising biometry for best outcomes in cataract surgery.

Authors:  R Sheard
Journal:  Eye (Lond)       Date:  2013-12-06       Impact factor: 3.775

6.  Microincisional cataract surgery and Thinoptx rollable intraocular lens implantation.

Authors:  Necdet Cinhüseyinoglu; Lider Celik; Aylin Yaman; Gül Arikan; Tülin Kaynak; Süleyman Kaynak
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2005-11-29       Impact factor: 3.117

7.  [Biometry in cataract camps. Experiences from north Kenya].

Authors:  S Briesen; H Roberts; J Karimurio; M Kollmann
Journal:  Ophthalmologe       Date:  2010-04       Impact factor: 1.059

8.  Factors influencing the accuracy of the SRK formula in the intraocular less power calculation.

Authors:  C Kalogeropoulos; M Aspiotis; M Stefaniotou; K Psilas
Journal:  Doc Ophthalmol       Date:  1994       Impact factor: 2.379

9.  [Individualization of IOL constants for two hydrophobic intraocular lenses. SRK II, SRK/T, Hoffer-Q, Holladay 1 and Haigis formula].

Authors:  A Langenbucher; T Eppig; A Viestenz; B Seitz; G Müllner; U Schönherr
Journal:  Ophthalmologe       Date:  2012-05       Impact factor: 1.059

10.  Intraocular lens calculation by intraoperative autorefraction in myopic eyes.

Authors:  Antonio Leccisotti
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2007-06-29       Impact factor: 3.117

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.