Literature DB >> 7924850

Factors influencing the accuracy of the SRK formula in the intraocular less power calculation.

C Kalogeropoulos1, M Aspiotis, M Stefaniotou, K Psilas.   

Abstract

Several intraocular lens (IOL) power calculation formulas (either theoretical or empirical) are used to determine the emmetropic IOL power) The Sanders-Retzlaff-Kraff (SRK) linear regression formula is among the most widely recognized empirical ones. In the present study intraocular lens power calculation aiming at emmetropia was performed, using SRK formula, in 145 cataractous eyes undergoing lens implantation. The final refraction was evaluated at 8 to 12 months after surgery. The purpose of this study was the identification and quantitative evaluation of the factors which influence significantly the accuracy of SRK in the intraocular lens power calculation. The following factors were studied: (1) the error in preoperative biometry with regard to the difference between post and preoperative axial length measurements, (2) the position of the implantation of the intraocular lens (anterior versus posterior chamber), (3) the intraocular lens style, (4) the intraocular lens power level, (5) the preoperative corneal astigmatism, (6) the surgically induced corneal astigmatism, and (7) the postoperative astigmatism. Multiple regression and stepwise regression analysis showed a strong correlation (R2 = 0.65; p < 0.001) between postoperative refractive error (Rf) and error in preoperative biometry (delta AL), surgically induced corneal astigmatism (SIA) and postoperative astigmatism (Ap) only. This correlation is expressed by the following equation: Rf = 0.07 -2.55 delta AL -0.42 SIA + 0.34 Ap. This equation indicates the quantitative effect of each factor on the accuracy of the SRK formula, by defining the pattern of the fluctuations of the amount or state (myopic or hyperopic) of refractive error induced by changes of variables delta AL, SIA and Ap.

Entities:  

Mesh:

Year:  1994        PMID: 7924850     DOI: 10.1007/bf01664930

Source DB:  PubMed          Journal:  Doc Ophthalmol        ISSN: 0012-4486            Impact factor:   2.379


  47 in total

1.  THE ECHOGRAM OF THE NORMAL AND OPAQUE LENS.

Authors:  A OKSALA; E R VARONEN
Journal:  Acta Ophthalmol (Copenh)       Date:  1965

2.  The reproducibility of biometry and keratometry measurements.

Authors:  J M Butcher; C O'Brien
Journal:  Eye (Lond)       Date:  1991       Impact factor: 3.775

3.  Posterior chamber implants and post-operative refractive astigmatism.

Authors:  B A Maltzman; D J Cinotti; C A Horan; A M Rengel
Journal:  CLAO J       Date:  1983 Jul-Sep

4.  Influence of intraocular lenses on ultrasound axial length measurement: in vitro and in vivo studies.

Authors:  H Freudiger; L Artaria; P Niesel
Journal:  J Am Intraocul Implant Soc       Date:  1984

5.  Accuracy of ultrasound intraocular lens calculation.

Authors:  K J Hoffer
Journal:  Arch Ophthalmol       Date:  1981-10

6.  Lens power calculation--is it necessary?

Authors:  P Percival
Journal:  Trans Ophthalmol Soc U K       Date:  1983

7.  Corneal astigmatism following cataract extraction.

Authors:  M S Wishart; P K Wishart; Z J Gregor
Journal:  Br J Ophthalmol       Date:  1986-11       Impact factor: 4.638

8.  Can the accuracy of intraocular lens calculations be improved?

Authors:  D J Mitchell
Journal:  Ophthalmic Surg       Date:  1988-08

9.  The selection of intraocular lens power by calculation and by reference to the refraction--a clinical study.

Authors:  J S Hillman
Journal:  Trans Ophthalmol Soc U K       Date:  1982

10.  Factors associated with poor predictability by intraocular lens calculation formulas.

Authors:  S C Richards; R J Olson; W L Richards
Journal:  Arch Ophthalmol       Date:  1985-04
View more
  1 in total

1.  [Individualization of IOL constants for two hydrophobic intraocular lenses. SRK II, SRK/T, Hoffer-Q, Holladay 1 and Haigis formula].

Authors:  A Langenbucher; T Eppig; A Viestenz; B Seitz; G Müllner; U Schönherr
Journal:  Ophthalmologe       Date:  2012-05       Impact factor: 1.059

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.