Literature DB >> 1390516

Calculation of the power of anterior chamber implants.

J R Villada1, P S Raj, T Akingbehin.   

Abstract

Ninety seven eyes with anterior chamber implants and a best corrected visual acuity of at least 6/12 were studied, firstly, to compare the predictive accuracies of the commonly used formulas for intraocular lens (IOL) power calculation and, secondly, to determine the effect of optimising the 'A' constant on the predictive accuracies of the empirical Sanders-Retzlaff-Kraff (SRK) formulas. The accuracies of the empirical formulas (SRK and SRK II) were generally similar to those of the theoretical formulas (Binkhorst II and Colenbrander-Hoffer). However the original SRK formula was more accurate than the two theoretical formulas in long eyes and in all eyes overall. Optimisation of the 'A' constants did not improve the predictive accuracy of the empirical SRK formulas.

Mesh:

Year:  1992        PMID: 1390516      PMCID: PMC504263          DOI: 10.1136/bjo.76.5.303

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  20 in total

1.  A three-part system for refining intraocular lens power calculations.

Authors:  J T Holladay; T C Prager; T Y Chandler; K H Musgrove; J W Lewis; R S Ruiz
Journal:  J Cataract Refract Surg       Date:  1988-01       Impact factor: 3.351

2.  Comparison of the SRK/T formula and other theoretical and regression formulas.

Authors:  D R Sanders; J A Retzlaff; M C Kraff; H V Gimbel; M G Raanan
Journal:  J Cataract Refract Surg       Date:  1990-05       Impact factor: 3.351

3.  Accuracy of routine intraocular lens power calculation in a district general hospital.

Authors:  P T Gregory; R M Esbester; D L Boase
Journal:  Br J Ophthalmol       Date:  1989-01       Impact factor: 4.638

4.  A simple BASIC computer program to individualize the SRK formula.

Authors:  M Lugo
Journal:  Arch Ophthalmol       Date:  1986-05

5.  Significance of intraocular lens power calculation.

Authors:  M Singh; A Dahalan
Journal:  Br J Ophthalmol       Date:  1987-11       Impact factor: 4.638

6.  [Dioptric value of artificial eye lenses].

Authors:  C D Binkhorst
Journal:  Klin Monbl Augenheilkd       Date:  1973-03       Impact factor: 0.700

7.  Calculation of intraocular lens power--results in practice.

Authors:  B L Halliday
Journal:  Trans Ophthalmol Soc U K       Date:  1986

8.  Comparison of the accuracy of the Binkhorst, Colenbrander, and SRK implant power prediction formulas.

Authors:  D Sanders; J Retzlaff; M Kraff; R Kratz; J Gills; R Levine; M Colvard; J Weisel; T Loyd
Journal:  J Am Intraocul Implant Soc       Date:  1981

9.  Lens power calculation--is it necessary?

Authors:  P Percival
Journal:  Trans Ophthalmol Soc U K       Date:  1983

10.  Comparison of the SRK II formula and other second generation formulas.

Authors:  D R Sanders; J Retzlaff; M C Kraff
Journal:  J Cataract Refract Surg       Date:  1988-03       Impact factor: 3.351

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.