Literature DB >> 33441815

A pilot study for intraocular pressure measurements based on vibroacoustic parameters.

Deukha Kim1, Youngbeen Chung1, Yeji Yeon2, Hyunsoo Cho2, Han Woong Lim2,3, Junhong Park1, Won June Lee4,5.   

Abstract

The present study aimed to identify vibroacoustic properties associated with intraocular pressure (IOP) changes and to suggest a new way to measure the IOP based on these properties. Ten ex vivo porcine eyeballs were used in this study. Each eyeball was fixated in a central hole of a Styrofoam block, and vibration applied to the Styrofoam block was transmitted to the eyeball. An accelerometer directly attached to the eyeball measured the vibration response. Excitations and measurements were performed for 1 s, and the excitation magnitude was varied for the same signal in repeat measurements. A 30-gauge needle was inserted into the anterior chamber of the eyeball to inject a balanced salt solution, and the height of the bottle was adjusted to adjust the IOP. A tonometer was used under identical conditions to measure the IOP five times, and the mean value was determined for further analyses. The measurements showed that the parameters resonance frequency and change in the magnitude of the vibration response (CMVR) increased with rising IOP values. The CMVR was highly correlated with the IOP (p-value < 0.0001). A linear mixed effects model (LMM) was used as a statistical analysis method. We confirmed that vibroacoustic properties of the eyeball are correlated with IOP changes. It is expected that the CMVR will serve as a new parameter for IOP measurements. Thus, in the future, continuous IOP measurements would be easily performed using the CMVR.

Entities:  

Year:  2021        PMID: 33441815      PMCID: PMC7806898          DOI: 10.1038/s41598-020-80321-1

Source DB:  PubMed          Journal:  Sci Rep        ISSN: 2045-2322            Impact factor:   4.379


  26 in total

1.  Comparison of dynamic contour tonometry with goldmann applanation tonometry.

Authors:  Claude Kaufmann; Lucas M Bachmann; Michael A Thiel
Journal:  Invest Ophthalmol Vis Sci       Date:  2004-09       Impact factor: 4.799

2.  Reproducibility and clinical evaluation of rebound tonometry.

Authors:  Jose M Martinez-de-la-Casa; Julian Garcia-Feijoo; Alfredo Castillo; Julian Garcia-Sanchez
Journal:  Invest Ophthalmol Vis Sci       Date:  2005-12       Impact factor: 4.799

Review 3.  24-h monitoring devices and nyctohemeral rhythms of intraocular pressure.

Authors:  Florent Aptel; Robert N Weinreb; Christophe Chiquet; Kaweh Mansouri
Journal:  Prog Retin Eye Res       Date:  2016-07-28       Impact factor: 21.198

4.  A corneal elastic dynamic model derived from Scheimpflug imaging technology.

Authors:  Po-Jen Shih; Huei-Jyun Cao; Chun-Ju Huang; I-Jong Wang; Wen-Pin Shih; Jia-Yush Yen
Journal:  Ophthalmic Physiol Opt       Date:  2015-09-09       Impact factor: 3.117

Review 5.  New ways to measure intraocular pressure.

Authors:  Mohammed K ElMallah; Sanjay G Asrani
Journal:  Curr Opin Ophthalmol       Date:  2008-03       Impact factor: 3.761

Review 6.  The pathophysiology and treatment of glaucoma: a review.

Authors:  Robert N Weinreb; Tin Aung; Felipe A Medeiros
Journal:  JAMA       Date:  2014-05-14       Impact factor: 56.272

7.  Numerical model of optical coherence tomographic vibrography imaging to estimate corneal biomechanical properties.

Authors:  Sabine Kling; Imran B Akca; Ernest W Chang; Giuliano Scarcelli; Nandor Bekesi; Seok-Hyun Yun; Susana Marcos
Journal:  J R Soc Interface       Date:  2014-12-06       Impact factor: 4.118

8.  Correlation of IOP with Corneal Acoustic Impedance in Porcine Eye Model.

Authors:  Jun Zhang; Yi Zhang; Yang Li; Ruimin Chen; K Kirk Shung; Grace Richter; Qifa Zhou
Journal:  Biomed Res Int       Date:  2017-05-31       Impact factor: 3.411

9.  Determination of the modulus of elasticity of the human cornea.

Authors:  Ahmed Elsheikh; Defu Wang; David Pye
Journal:  J Refract Surg       Date:  2007-10       Impact factor: 3.573

Review 10.  Icare® rebound tonometers: review of their characteristics and ease of use.

Authors:  Shunsuke Nakakura
Journal:  Clin Ophthalmol       Date:  2018-07-12
View more
  1 in total

1.  Eye orbit effects on eyeball resonant frequencies and acoustic tonometer measurements.

Authors:  Po-Jen Shih; Shao-Jie Wu; Ya-Hsing Sung; Yu-Ting Tung; Chia-Yu Chang; Shadie Hatamie; Zhi-Xuan Dai
Journal:  Sci Rep       Date:  2022-03-22       Impact factor: 4.379

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.