Literature DB >> 27477112

24-h monitoring devices and nyctohemeral rhythms of intraocular pressure.

Florent Aptel1, Robert N Weinreb2, Christophe Chiquet1, Kaweh Mansouri3.   

Abstract

Intraocular pressure (IOP) is not a fixed value and varies over both the short term and periods lasting several months or years. In particular, IOP is known to vary throughout the 24-h period of a day, defined as a nyctohemeral rhythm in humans. In clinical practice, it is crucial to evaluate the changes in IOP over 24 h in several situations, including the diagnosis of ocular hypertension and glaucoma (IOP is often higher at night) and to optimize the therapeutic management of glaucoma. Until recently, all evaluations of 24-h IOP rhythm were performed using repeated IOP measurements, requiring individuals to be awakened for nocturnal measurements. This method may be imperfect, because it is not physiologic and disturbs the sleep architecture, and also because it provides a limited number of time point measurements not sufficient to finely asses IOP changes. These limitations may have biased previous descriptions of physiological IOP rhythm. Recently, extraocular and intraocular devices integrating a pressure sensor for continuous IOP monitoring have been developed and are available for use in humans. The objective of this article is to present the contributions of these new 24-h monitoring devices for the study of the nyctohemeral rhythms. In healthy subjects and untreated glaucoma subjects, a nyctohemeral rhythm is consistently found and frequently characterized by a mean diurnal IOP lower than the mean nocturnal IOP, with a diurnal bathyphase - usually in the middle or at the end of the afternoon - and a nocturnal acrophase, usually in the middle or at the end of the night.
Copyright © 2016 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  24-h monitoring; Circadian; Contact lens sensor; Glaucoma; Intraocular pressure; Nyctohemeral

Mesh:

Year:  2016        PMID: 27477112     DOI: 10.1016/j.preteyeres.2016.07.002

Source DB:  PubMed          Journal:  Prog Retin Eye Res        ISSN: 1350-9462            Impact factor:   21.198


  18 in total

1.  The Diurnal and Nocturnal Effects of Pilocarpine on Intraocular Pressure in Patients Receiving Prostaglandin Analog Monotherapy.

Authors:  Leonard K Seibold; Brandie D Wagner; Anne M Lynch; Malik Y Kahook
Journal:  J Ocul Pharmacol Ther       Date:  2018-09-07       Impact factor: 2.671

2.  Diurnal macular choroidal area fluctuation in normal and primary open angle glaucoma groups.

Authors:  Mu Li; Jin-Min Guo; Xiao-Lan Xu; Jun-Ming Wang
Journal:  Int J Ophthalmol       Date:  2017-08-18       Impact factor: 1.779

Review 3.  Regulation of Cell Behavior by Hydrostatic Pressure.

Authors:  Shaobao Liu; Ru Tao; Ming Wang; Jin Tian; Guy M Genin; Tian Jian Lu; Feng Xu
Journal:  Appl Mech Rev       Date:  2019-07-23       Impact factor: 7.281

4.  Effect of body position on the pathogenesis of asymmetric primary open angle glaucoma.

Authors:  Jing Tang; Ni Li; Ying-Ping Deng; Le-Mei Qiu; Xiao-Ming Chen
Journal:  Int J Ophthalmol       Date:  2018-01-18       Impact factor: 1.779

5.  Induction of significant intraocular pressure diurnal fluctuation in rats using a modified technique of microbead occlusion.

Authors:  Lin Fu; Jimmy Shiu Ming Lai; Amy Cheuk Yin Lo; Kendrick Co Shih
Journal:  Int J Ophthalmol       Date:  2018-07-18       Impact factor: 1.779

6.  Genomic Locus Modulating IOP in the BXD RI Mouse Strains.

Authors:  Rebecca King; Ying Li; Jiaxing Wang; Felix L Struebing; Eldon E Geisert
Journal:  G3 (Bethesda)       Date:  2018-05-04       Impact factor: 3.154

7.  The increased expression of GABA receptors within the arcuate nucleus is associated with high intraocular pressure.

Authors:  Jie-Ling Gong; Xiao-Tong Lou; Yu-Xiang Yuan; Li-Wen Chen; Ping-Ting Ji; Lu Li; Yin Zhao; Hong Zhang
Journal:  Mol Vis       Date:  2018-08-15       Impact factor: 2.367

8.  Automated, Noncontact Intraocular Pressure Home Monitoring after Implantation of a Novel Telemetric Intraocular Pressure Sensor in Patients with Glaucoma: A Feasibility Study.

Authors:  Antonis Koutsonas; Peter Walter; David Kuerten; Niklas Plange
Journal:  Biomed Res Int       Date:  2018-12-06       Impact factor: 3.411

9.  Continuous intraocular pressure monitoring in patients with obstructive sleep apnea syndrome using a contact lens sensor.

Authors:  Elena Carnero; Jean Bragard; Elena Urrestarazu; Estefanía Rivas; Vicente Polo; José Manuel Larrosa; Vanesa Antón; Antonio Peláez; Javier Moreno-Montañés
Journal:  PLoS One       Date:  2020-03-03       Impact factor: 3.240

Review 10.  Diurnal and 24-h Intraocular Pressures in Glaucoma: Monitoring Strategies and Impact on Prognosis and Treatment.

Authors:  Anastasios G Konstas; Malik Y Kahook; Makoto Araie; Andreas Katsanos; Luciano Quaranta; Luca Rossetti; Gábor Holló; Efstathios T Detorakis; Francesco Oddone; Dimitrios G Mikropoulos; Gordon N Dutton
Journal:  Adv Ther       Date:  2018-10-20       Impact factor: 3.845

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.