Long-term Inter-protocol kV CBCT image quality assessment for a ring-gantry linac via automated QA approach.

Jiayuan Peng1, Hua Li, Eric Laugeman, Thomas Mazur, Dao Lam, Taoran Li, Baozhou Sun, Weigang Hu, Lei Dong, Geoffrey D Hugo, Sasa Mutic, Bin Cai.   

Abstract

We develop a fully automated QA process to compare the image quality of all kV CBCT protocols on a Halcyon linac with ring gantry design, and evaluate image quality stability over a 10-month period. A total of 19 imaging scan and reconstruction protocols were characterized with measurement on a newly released QUART phantom. A set of image analysis algorithms were developed and integrated into an automated analysis suite to derive key image quality metrics, including HU value accuracy on density inserts, HU uniformity using the background plate, high contrast resolution with the modulation transfer function (MTF) from the edge profiles, low contrast resolution using the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), slice thickness with the air gap modules, and geometric accuracy with the diameter of the phantom. Image quality data over 10 months was tracked and analyzed to evaluate the stability of the Halcyon kV imaging system. The HU accuracy over all 19 protocols is within tolerance (±50HU). The maximum uniformity deviation is 12.2 HU. The SNR and CNR, depending on the protocol selected, range from 18.5-911.9 and 1.9-102.8, respectively. A much-improved SNR and CNR were observed for iterative reconstruction (iCBCT) modes and protocols designed for large subjects over low dose and fast scanning modes. The Head and Image Gently protocols have the greatest high contrast resolution with MTF10% over 1 lp/mm and MTF50% over 0.6 lp/mm. The iCBCT mode slightly improved the MTF10% and MTF50% compared to the Feldkamp-Davis-Kress approach. The slice thickness (maximum error of 0.31 mm) and geometry metrics (maximum error of 0.7 mm) are all within tolerance (±0.5 mm for slice thickness and ±1 mm for geometry metrics). The long-term study over 10-month showed no significant drift for all key image quality metrics, which indicated the kV CBCT image quality is stable over time.

Entities:  

Year:  2020        PMID: 33438613      PMCID: PMC8189651          DOI: 10.1088/2057-1976/ab693a

Source DB:  PubMed          Journal:  Biomed Phys Eng Express        ISSN: 2057-1976


  9 in total

1.  Clinical use of electronic portal imaging: report of AAPM Radiation Therapy Committee Task Group 58.

Authors:  M G Herman; J M Balter; D A Jaffray; K P McGee; P Munro; S Shalev; M Van Herk; J W Wong
Journal:  Med Phys       Date:  2001-05       Impact factor: 4.071

2.  Quality assurance for image-guided radiation therapy utilizing CT-based technologies: a report of the AAPM TG-179.

Authors:  Jean-Pierre Bissonnette; Peter A Balter; Lei Dong; Katja M Langen; D Michael Lovelock; Moyed Miften; Douglas J Moseley; Jean Pouliot; Jan-Jakob Sonke; Sua Yoo
Journal:  Med Phys       Date:  2012-04       Impact factor: 4.071

3.  A quality assurance program for image quality of cone-beam CT guidance in radiation therapy.

Authors:  Jean-Pierre Bissonnette; Douglas J Moseley; David A Jaffray
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

4.  Task Group 142 report: quality assurance of medical accelerators.

Authors:  Eric E Klein; Joseph Hanley; John Bayouth; Fang-Fang Yin; William Simon; Sean Dresser; Christopher Serago; Francisco Aguirre; Lijun Ma; Bijan Arjomandy; Chihray Liu; Carlos Sandin; Todd Holmes
Journal:  Med Phys       Date:  2009-09       Impact factor: 4.071

5.  Image guided radiation therapy (IGRT) technologies for radiation therapy localization and delivery.

Authors:  Jennifer De Los Santos; Richard Popple; Nzhde Agazaryan; John E Bayouth; Jean-Pierre Bissonnette; Mary Kara Bucci; Sonja Dieterich; Lei Dong; Kenneth M Forster; Daniel Indelicato; Katja Langen; Joerg Lehmann; Nina Mayr; Ishmael Parsai; William Salter; Michael Tomblyn; William T C Yuh; Indrin J Chetty
Journal:  Int J Radiat Oncol Biol Phys       Date:  2013-05-07       Impact factor: 7.038

6.  Characterization of a prototype rapid kilovoltage x-ray image guidance system designed for a ring shape radiation therapy unit.

Authors:  Bin Cai; Eric Laugeman; Thomas R Mazur; Justin C Park; Lauren E Henke; Hyun Kim; Geoffrey D Hugo; Sasa Mutic; Hua Li
Journal:  Med Phys       Date:  2019-02-13       Impact factor: 4.071

7.  A quality assurance framework for the fully automated and objective evaluation of image quality in cone-beam computed tomography.

Authors:  Christian Steiding; Daniel Kolditz; Willi A Kalender
Journal:  Med Phys       Date:  2014-03       Impact factor: 4.071

8.  Real-time volumetric relative dosimetry for magnetic resonance-image-guided radiation therapy (MR-IGRT).

Authors:  Hannah J Lee; Mo Kadbi; Gary Bosco; Geoffrey S Ibbott
Journal:  Phys Med Biol       Date:  2018-02-20       Impact factor: 3.609

9.  Clinical experiences with onboard imager KV images for linear accelerator-based stereotactic radiosurgery and radiotherapy setup.

Authors:  Linda X Hong; Chin C Chen; Madhur Garg; Ravindra Yaparpalvi; Dennis Mah
Journal:  Int J Radiat Oncol Biol Phys       Date:  2009-02-01       Impact factor: 7.038

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.