Real-time volumetric relative dosimetry for magnetic resonance-image-guided radiation therapy (MR-IGRT).

Hannah J Lee1, Mo Kadbi, Gary Bosco, Geoffrey S Ibbott.   

Abstract

The integration of magnetic resonance imaging (MRI) with linear accelerators (linac) has enabled the use of 3D MR-visible gel dosimeters for real-time verification of volumetric dose distributions. Several iron-based radiochromic 3D gels were created in-house then imaged and irradiated in a pre-clinical 1.5 T-7 MV MR-Linac. MR images were acquired using a range of balanced-fast field echo (b-FFE) sequences during irradiation to assess the contrast and dose response in irradiated regions and to minimize the presence of MR artifacts. Out of four radiochromic 3D gel formulations, the FOX 3D gel was found to provide superior MR contrast in the irradiated regions. The FOX gels responded linearly with respect to real-time dose and the signal remained stable post-irradiation for at least 20 min. The response of the FOX gel also was found to be unaffected by the radiofrequency and gradient fields created by the b-FFE sequence during irradiation. A reusable version of the FOX gel was used for b-FFE sequence optimization to reduce artifacts by increasing the number of averages at the expense of temporal resolution. Regardless of the real-time MR sequence used, the FOX 3D gels responded linearly to dose with minimal magnetic field effects due to the strong 1.5 T field or gradient fields present during imaging. These gels can easily be made in-house using non-reusable and reusable formulations depending on the needs of the clinic, and the results of this study encourage further applications of 3D gels for MR-IGRT applications.

Entities:  

Mesh:

Year:  2018        PMID: 29384731     DOI: 10.1088/1361-6560/aaac22

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  Radiological tissue equivalence of deformable silicone-based chemical radiation dosimeters (FlexyDos3D).

Authors:  Yi Du; Ruoxi Wang; Meijiao Wang; Haizhen Yue; Yibao Zhang; Hao Wu; Weihu Wang
Journal:  J Appl Clin Med Phys       Date:  2019-06-11       Impact factor: 2.102

2.  Long-term Inter-protocol kV CBCT image quality assessment for a ring-gantry linac via automated QA approach.

Authors:  Jiayuan Peng; Hua Li; Eric Laugeman; Thomas Mazur; Dao Lam; Taoran Li; Baozhou Sun; Weigang Hu; Lei Dong; Geoffrey D Hugo; Sasa Mutic; Bin Cai
Journal:  Biomed Phys Eng Express       Date:  2020-01-20

3.  Optical imaging method to quantify spatial dose variation due to the electron return effect in an MR-linac.

Authors:  Jacqueline M Andreozzi; Petr Brůža; Jochen Cammin; Brian W Pogue; David J Gladstone; Olga Green
Journal:  Med Phys       Date:  2019-12-25       Impact factor: 4.071

4.  3D star shot analysis using MAGAT gel dosimeter for integrated imaging and radiation isocenter verification of MR-Linac system.

Authors:  Jeong Ho Kim; Bitbyeol Kim; Wook-Geun Shin; Jaeman Son; Chang Heon Choi; Jong Min Park; Ui-Jung Hwang; Jung-In Kim; Seongmoon Jung
Journal:  J Appl Clin Med Phys       Date:  2022-04-18       Impact factor: 2.243

Review 5.  Radiation Dosimetry by Use of Radiosensitive Hydrogels and Polymers: Mechanisms, State-of-the-Art and Perspective from 3D to 4D.

Authors:  Yves De Deene
Journal:  Gels       Date:  2022-09-19
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.