Clinical experiences with onboard imager KV images for linear accelerator-based stereotactic radiosurgery and radiotherapy setup.

Linda X Hong1, Chin C Chen, Madhur Garg, Ravindra Yaparpalvi, Dennis Mah.   

Abstract

PURPOSE: To report our clinical experiences with on-board imager (OBI) kV image verification for cranial stereotactic radiosurgery (SRS) and radiotherapy (SRT) treatments. METHODS AND MATERIALS: Between January 2007 and May 2008, 42 patients (57 lesions) were treated with SRS with head frame immobilization and 13 patients (14 lesions) were treated with SRT with face mask immobilization at our institution. No margin was added to the gross tumor for SRS patients, and a 3-mm three-dimensional margin was added to the gross tumor to create the planning target volume for SRT patients. After localizing the patient with stereotactic target positioner (TaPo), orthogonal kV images using OBI were taken and fused to planning digital reconstructed radiographs. Suggested couch shifts in vertical, longitudinal, and lateral directions were recorded. kV images were also taken immediately after treatment for 21 SRS patients and on a weekly basis for 6 SRT patients to assess any intrafraction changes.
RESULTS: For SRS patients, 57 pretreatment kV images were evaluated and the suggested shifts were all within 1 mm in any direction (i.e., within the accuracy of image fusion). For SRT patients, the suggested shifts were out of the 3-mm tolerance for 31 of 309 setups. Intrafraction motions were detected in 3 SRT patients.
CONCLUSIONS: kV imaging provided a useful tool for SRS or SRT setups. For SRS setup with head frame, it provides radiographic confirmation of localization using the stereotactic target positioner. For SRT with mask, a 3-mm margin is adequate and feasible for routine setup when TaPo is combined with kV imaging.

Entities:  

Mesh:

Year:  2009        PMID: 19147020     DOI: 10.1016/j.ijrobp.2008.09.055

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  4 in total

1.  Long-term Inter-protocol kV CBCT image quality assessment for a ring-gantry linac via automated QA approach.

Authors:  Jiayuan Peng; Hua Li; Eric Laugeman; Thomas Mazur; Dao Lam; Taoran Li; Baozhou Sun; Weigang Hu; Lei Dong; Geoffrey D Hugo; Sasa Mutic; Bin Cai
Journal:  Biomed Phys Eng Express       Date:  2020-01-20

2.  Analysis of the Setup Uncertainty and Margin of the Daily ExacTrac 6D Image Guide System for Patients with Brain Tumors.

Authors:  Se An Oh; Ji Woon Yea; Min Kyu Kang; Jae Won Park; Sung Kyu Kim
Journal:  PLoS One       Date:  2016-03-28       Impact factor: 3.240

3.  Clinical commissioning of a new patient positioning system, SyncTraX FX4, for intracranial stereotactic radiotherapy.

Authors:  Satoshi Tanabe; Osamu Umetsu; Toshikazu Sasage; Satoru Utsunomiya; Ryota Kuwabara; Toshiki Kuribayashi; Hiromasa Takatou; Gen Kawaguchi; Hidefumi Aoyama
Journal:  J Appl Clin Med Phys       Date:  2018-10-01       Impact factor: 2.102

4.  Performance assessment of two motion management systems for frameless stereotactic radiosurgery.

Authors:  Hao Wang; Zhiyong Xu; Kevin Grantham; Yongkang Zhou; Taoran Cui; Yin Zhang; Bo Liu; Xiao Wang; Irina Vergalasova; Meral Reyhan; Joseph Weiner; Shabbar F Danish; Ning Yue; Ke Nie
Journal:  Strahlenther Onkol       Date:  2020-10-12       Impact factor: 3.621

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.