Literature DB >> 33432448

Generation of Brain Dual-Energy CT from Single-Energy CT Using Deep Learning.

Chi-Kuang Liu1, Chih-Chieh Liu2, Cheng-Hsun Yang3, Hsuan-Ming Huang4.   

Abstract

Deep learning (DL) has shown great potential in conversions between various imaging modalities. Similarly, DL can be applied to synthesize a high-kV computed tomography (CT) image from its corresponding low-kV CT image. This indicates the feasibility of obtaining dual-energy CT (DECT) images without purchasing a DECT scanner. In this study, we investigated whether a low-to-high kV mapping was better than a high-to-low kV mapping. We used a U-Net model to perform conversions between different kV CT images. Moreover, we proposed a double U-Net model to improve the quality of original single-energy CT images. Ninety-eight patients who underwent brain DECT scans were used to train, validate, and test the proposed DL-based model. The results showed that the low-to-high kV conversion was better than the high-to-low kV conversion. In addition, the DL-based DECT images had better signal-to-noise ratios (SNRs) than the true (original) DECT images, but at the expense of a slight loss in spatial resolution. The mean CT number differences between the true and DL-based DECT images were within [Formula: see text] 1 HU. No statistically significant difference in CT number measurements was found between the true and DL-based DECT images (p > 0.05). The DL-based DECT images with improved SNR could produce low-noise virtual monoenergetic images. Our preliminary results indicate that DL has the potential to generate brain DECT images using single-energy brain CT images.

Entities:  

Keywords:  Deep learning; Dual-energy computed tomography; U-net

Mesh:

Year:  2021        PMID: 33432448      PMCID: PMC7887134          DOI: 10.1007/s10278-020-00414-1

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  18 in total

1.  Impact of new technologies on dose reduction in CT.

Authors:  Ting-Yim Lee; Rethy K Chhem
Journal:  Eur J Radiol       Date:  2010-10       Impact factor: 3.528

2.  Zero-Echo-Time and Dixon Deep Pseudo-CT (ZeDD CT): Direct Generation of Pseudo-CT Images for Pelvic PET/MRI Attenuation Correction Using Deep Convolutional Neural Networks with Multiparametric MRI.

Authors:  Andrew P Leynes; Jaewon Yang; Florian Wiesinger; Sandeep S Kaushik; Dattesh D Shanbhag; Youngho Seo; Thomas A Hope; Peder E Z Larson
Journal:  J Nucl Med       Date:  2017-10-30       Impact factor: 10.057

3.  Clinical routine use of virtual monochromatic datasets based on spectral CT in patients with hypervascularized abdominal tumors - evaluation of effectiveness and efficiency.

Authors:  Georg Böning; Felix Feldhaus; Sebastian Adelt; Johannes Kahn; Uli Fehrenbach; Florian Streitparth
Journal:  Acta Radiol       Date:  2018-06-27       Impact factor: 1.990

4.  First performance evaluation of a dual-source CT (DSCT) system.

Authors:  Thomas G Flohr; Cynthia H McCollough; Herbert Bruder; Martin Petersilka; Klaus Gruber; Christoph Süss; Michael Grasruck; Karl Stierstorfer; Bernhard Krauss; Rainer Raupach; Andrew N Primak; Axel Küttner; Stefan Achenbach; Christoph Becker; Andreas Kopp; Bernd M Ohnesorge
Journal:  Eur Radiol       Date:  2005-12-10       Impact factor: 5.315

Review 5.  A gentle introduction to deep learning in medical image processing.

Authors:  Andreas Maier; Christopher Syben; Tobias Lasser; Christian Riess
Journal:  Z Med Phys       Date:  2019-01-25       Impact factor: 4.820

6.  Assessment of hepatic fatty infiltration using dual-energy computed tomography: a phantom study.

Authors:  Jung-Hui Li; Chang-Yu Tsai; Hsuan-Ming Huang
Journal:  Physiol Meas       Date:  2014-03-12       Impact factor: 2.833

Review 7.  Dual energy CT in radiotherapy: Current applications and future outlook.

Authors:  Wouter van Elmpt; Guillaume Landry; Marco Das; Frank Verhaegen
Journal:  Radiother Oncol       Date:  2016-03-11       Impact factor: 6.280

8.  Dual-source dual-energy CT with additional tin filtration: Dose and image quality evaluation in phantoms and in vivo.

Authors:  Andrew N Primak; Juan Carlos Ramirez Giraldo; Christian D Eusemann; Bernhard Schmidt; Birgit Kantor; Joel G Fletcher; Cynthia H McCollough
Journal:  AJR Am J Roentgenol       Date:  2010-11       Impact factor: 3.959

Review 9.  Deep Learning in Medical Image Analysis.

Authors:  Dinggang Shen; Guorong Wu; Heung-Il Suk
Journal:  Annu Rev Biomed Eng       Date:  2017-03-09       Impact factor: 9.590

Review 10.  Dual-Energy CT: New Horizon in Medical Imaging.

Authors:  Hyun Woo Goo; Jin Mo Goo
Journal:  Korean J Radiol       Date:  2017-05-19       Impact factor: 3.500

View more
  1 in total

1.  Deep Learning and Domain-Specific Knowledge to Segment the Liver from Synthetic Dual Energy CT Iodine Scans.

Authors:  Usman Mahmood; David D B Bates; Yusuf E Erdi; Lorenzo Mannelli; Giuseppe Corrias; Christopher Kanan
Journal:  Diagnostics (Basel)       Date:  2022-03-10
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.