| Literature DB >> 33401348 |
Joon Seop Lee1, Seong Woo Jeon1, Yong Hwan Kwon1.
Abstract
BACKGROUND/AIMS: To date, no reports have compared the diagnostic efficacy of narrow-band imaging (NBI) and i-scan for the histologic prediction of intermediate-to-large colorectal polyps. We aimed to compare the diagnostic accuracy of NBI and i-scan in predicting histology, and their inter-/intra-observer agreement.Entities:
Keywords: Colonoscopy; Colorectal neoplasms; Histology; Narrow-band imaging; i-scan
Year: 2021 PMID: 33401348 PMCID: PMC8652175 DOI: 10.5946/ce.2020.257
Source DB: PubMed Journal: Clin Endosc ISSN: 2234-2400
Fig. 1.Representative images of white-light endoscopy and narrow-band imaging (NBI) obtained from the enrolled patients. (A) Japan NBI Expert Team (JNET) classification 1. (B) JNET classification 2A. (C) JNET classification 2B. (D) JNET classification 3.
Fig. 2.Representative images of white-light endoscopy and i-scan obtained from the enrolled patients. (A) Japan Narrow-band Imaging Expert Team (JNET) classification 1. (B) JNET classification 2A. (C) JNET classification 2B. (D) JNET classification 3.
Baseline Characteristics of the Enrolled Patients
| NBI ( | i-scan ( | ||
|---|---|---|---|
| Sex, male | 18 (54.5) | 21 (63.6) | 0.453 |
| Age, yr | 62.50±8.63 | 61.50±11.35 | 0.913 |
| Comorbidity | 0.300 | ||
| None | 15 (45.5) | 22 (66.7) | 0.129 |
| Hypertension | 6 (18.2) | 7 (21.2) | |
| Diabetes mellitus | 4 (12.1) | 2 (6.1) | |
| Others[ | 8 (24.2) | 2 (6.1) | |
| History of abdominal surgery | 1 (3.0) | 5 (15.2) | 0.087 |
| Lesion size, mm | 18.20±6.98 | 19.80±7.13 | 0.264 |
| Lesion morphology | 0.473 | ||
| Pedunculated | 4 (12.1) | 3 (9.1) | |
| Semi-pedunculated | 9 (27.3) | 12 (36.4) | |
| Sessile | 10 (30.3) | 7 (21.2) | |
| LST-G | 5 (15.2) | 9 (27.3) | |
| LST-NG | 5 (15.2) | 2 (6.1) | |
| Endoscopist who performed the procedures | 0.422 | ||
| Endoscopist 1 | 16 (48.5) | 12 (36.4) | |
| Endoscopist 2 | 8 (24.2) | 7 (21.2) | |
| Endoscopist 3 | 9 (27.3) | 14 (42.4) |
Data are summarized as mean±standard deviation or number (%).
LST-G, laterally spreading tumor granular type; LST-NG, laterally spreading tumor non-granular type; NBI, narrow-band imaging.
Including cerebrovascular disease, chronic kidney disease, gout, hypothyroidism, and hyperthyroidism.
Diagnostic Accuracy of Narrow-Band Imaging and i-scan according to Endoscopist
| Narrow-band imaging | i-scan | ||
|---|---|---|---|
| All endoscopists | 73/99 (73.7) | 75/99 (75.8) | 0.744 |
| Endoscopist 1 | 25/33 (75.8) | 24/33 (72.7) | 0.778 |
| Endoscopist 2 | 24/33 (72.7) | 26/33 (78.8) | 0.566 |
| Endoscopist 3 | 24/33 (72.7) | 25/33 (75.8) | 0.778 |
Data are n (%).
Diagnostic Yield of Narrow-Band Imaging and i-scan according to Japan Narrow-Band Imaging Expert Team Classification
| Sensitivity | Specificity | PPV | NPV | Accuracy | |
|---|---|---|---|---|---|
| NBI | |||||
| JNET 1 ( | 100.0 | 100.0 | 100.0 | 100.0 | 100.0 |
| JNET 2A ( | 66.7 | 77.8 | 63.2 | 80.3 | 66.7 |
| JNET 2B ( | 72.6 | 81.3 | 81.3 | 73.3 | 72.5 |
| JNET 3 ( | 100.0 | 100.0 | 100.0 | 100.0 | 100.0 |
| i-scan | |||||
| JNET 1 ( | 88.9 | 97.8 | 86.7 | 98.9 | 88.9 |
| JNET 2A ( | 73.3 | 82.1 | 42.1 | 94.6 | 73.3 |
| JNET 2B ( | 73.2 | 82.6 | 91.6 | 54.9 | 73.6 |
| JNET 3 ( | 100.0 | 100.0 | 100.0 | 100.0 | 100.0 |
Data are %.
JNET, Japan NBI Expert Team; NBI, narrow-band imaging; NPV, negative predictive value; PPV, positive predictive value.
Inter-/Intra-Observer Agreements of Narrow-Band Imaging and i-scan according to Japan Narrow-Band Imaging Expert Team Classification
| NBI | i-scan | |||
|---|---|---|---|---|
| Inter-observer agreement | 0.612 | 0.001 | 0.662 | 0.002 |
| Intra-observer agreement | ||||
| Endoscopist 1 | 0.467 | 0.016 | 0.571 | 0.028 |
| Endoscopist 2 | 0.385 | 0.168 | 0.741 | 0.013 |
| Endoscopist 3 | 0.660 | 0.004 | 0.364 | 0.085 |
NBI, narrow-band imaging.