Literature DB >> 33378494

Stainless steel or titanium mini-implants?

Paulo Mecenas, Daybelis Gonzalez Espinosa, Paula Coutinho Cardoso, David Normando.   

Abstract

OBJECTIVES: To investigate whether there was a difference in success rates when stainless steel (SS) was compared to titanium mini-implants (MIs) in orthodontic patients.
MATERIALS AND METHODS: PubMed, Cochrane, Scopus, Web of Science, Lilacs, Google Scholar, Clinical Trials, and OpenGray were searched without restrictions. A manual search was also performed in the references of the included articles. Studies comparing the success rate between SS and titanium MIs were included. Risk of bias (RoB) was assessed using the ROBINS-I (Risk of Bias in Non-randomized Studies-of Interventions) Tool or RoB 2.0 according to the study design. The level of evidence was assessed through GRADE (Grading of Recommendation, Assessment, Development, and Evaluation).
RESULTS: Six studies met the eligibility criteria. One study was a randomized clinical trial that evaluated extraalveolar MIs, and nonrandomized trials examined interradicular MIs. The RCT presented a low RoB, two nonrandomized trials presented a moderate risk, and three presented a high risk. The quality of the evidence was high for the randomized clinical trial and moderate for the nonrandomized trials. Most studies found no difference between materials, with good success rates for both (SS, 74.6%-100%; titanium: 80.9%-100%) and only one study, with a high RoB, showed a higher success rate with titanium MIs (90%) when compared with SS (50%). A quantitative analysis was not because of the great heterogeneity among the studies.
CONCLUSIONS: Although limited, the current evidence seems to show that the material used is not a major factor in the success rate of MIs. Because it has a lower cost than titanium and presents similar clinical efficiency, SS is a great material for orthodontic MIs.
© 2020 by The EH Angle Education and Research Foundation, Inc.

Entities:  

Keywords:  Mini-implant; Review; Stainless steel; Success rate; TADs; Titanium

Mesh:

Substances:

Year:  2020        PMID: 33378494      PMCID: PMC8028470          DOI: 10.2319/081619-536.1

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  29 in total

1.  Mechanical properties evaluation of an orthodontic miniscrew system for skeletal anchorage.

Authors:  Daniele Francioli; Grazia Ruggiero; Roberto Giorgetti
Journal:  Prog Orthod       Date:  2010-05-15       Impact factor: 2.750

2.  GRADE guidelines: 3. Rating the quality of evidence.

Authors:  Howard Balshem; Mark Helfand; Holger J Schünemann; Andrew D Oxman; Regina Kunz; Jan Brozek; Gunn E Vist; Yngve Falck-Ytter; Joerg Meerpohl; Susan Norris; Gordon H Guyatt
Journal:  J Clin Epidemiol       Date:  2011-01-05       Impact factor: 6.437

3.  Comparison of anterior and posterior mini-implant-assisted maxillary incisor intrusion: Root resorption and treatment efficiency.

Authors:  Isil Aras; Ali V Tuncer
Journal:  Angle Orthod       Date:  2016-01-07       Impact factor: 2.079

4.  Failure rates for stainless steel versus titanium alloy infrazygomatic crest bone screws: A single-center, randomized double-blind clinical trial.

Authors:  Chris H Chang; Joshua S Lin; W Eugene Roberts
Journal:  Angle Orthod       Date:  2018-10-29       Impact factor: 2.079

5.  Orthodontic miniscrew failure rate and root proximity, insertion angle, bone contact length, and bone density.

Authors:  H Watanabe; T Deguchi; M Hasegawa; M Ito; S Kim; T Takano-Yamamoto
Journal:  Orthod Craniofac Res       Date:  2012-09-03       Impact factor: 1.826

6.  Miniscrews failure rate in orthodontics: systematic review and meta-analysis.

Authors:  Fahad Alharbi; Mohammed Almuzian; David Bearn
Journal:  Eur J Orthod       Date:  2018-09-28       Impact factor: 3.075

7.  A prospective study of factors associated with orthodontic mini-implant survival.

Authors:  Chia-Chun Tsai; Hong-Po Chang; Chin-Yun Pan; Szu-Ting Chou; Yu-Chuan Tseng
Journal:  J Oral Sci       Date:  2016       Impact factor: 1.556

8.  Titanium alloy vs. stainless steel miniscrews: an in vivo split-mouth study.

Authors:  P Bollero; V Di Fazio; C Pavoni; M Cordaro; P Cozza; R Lione
Journal:  Eur Rev Med Pharmacol Sci       Date:  2018-04       Impact factor: 3.507

Review 9.  Failure rates and associated risk factors of orthodontic miniscrew implants: a meta-analysis.

Authors:  Spyridon N Papageorgiou; Ioannis P Zogakis; Moschos A Papadopoulos
Journal:  Am J Orthod Dentofacial Orthop       Date:  2012-11       Impact factor: 2.650

10.  Biomechanics of extra-alveolar mini-implants.

Authors:  Marcio R Almeida
Journal:  Dental Press J Orthod       Date:  2019-09-05
View more
  1 in total

1.  Mechanical strength of stainless steel and titanium alloy mini-implants with different diameters: an experimental laboratory study.

Authors:  Sérgio Estelita Barros; Viviane Vanz; Kelly Chiqueto; Guilherme Janson; Eduardo Ferreira
Journal:  Prog Orthod       Date:  2021-03-22       Impact factor: 2.750

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.