Literature DB >> 29762818

Titanium alloy vs. stainless steel miniscrews: an in vivo split-mouth study.

P Bollero1, V Di Fazio, C Pavoni, M Cordaro, P Cozza, R Lione.   

Abstract

OBJECTIVE: To compare in vivo Titanium Alloy (TiA) with Stainless Steel (SS) miniscrews Temporary Anchorage Devices (TADs) using removal torque and Scanning Electron Microscopic (SEM) analysis. PATIENTS AND METHODS: 15 subjects (6 males and 9 females) who required maximum anchorage were recruited. For each patient, a TiA TAD and a SS TAD with same length and width were implanted following a randomized split-mouth study design. Retraction was carried out with nickel-titanium spring ligated directly from the anterior hooks of the archwire to the TADs to produce 90 to 100 g of force. When no further anchorage supplementation was needed, the TADs were removed. The removal torque values were registered with a digital screwdriver. After removal, the TADs were collected in a fixed solution and examined using SEM and X-ray microanalysis.
RESULTS: All TADs remained intact, with a 100% success rate. There was no difference in removal torque between TiA and SS miniscrews (4.4 ± 1.3 N-cm and 5.1 ± 0.7 N-cm, respectively). All specimens' loss of gloss with signs of biological contaminations resulted in a dull implant surface. SEM photomicrographs of TiA miniscrews showed predominantly blood cells while SS miniscrews showed the precipitation of an amorphous layer with low cellular component. There was no difference in spectroscopic analysis between TiA and SS miniscrews.
CONCLUSIONS: TiA and SS miniscrews had comparable removal torque values. SEM photomicrographs showed no evidence of osseointegration with both TADs having similar biological responses.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 29762818     DOI: 10.26355/eurrev_201804_14803

Source DB:  PubMed          Journal:  Eur Rev Med Pharmacol Sci        ISSN: 1128-3602            Impact factor:   3.507


  4 in total

1.  Stainless steel or titanium mini-implants?

Authors:  Paulo Mecenas; Daybelis Gonzalez Espinosa; Paula Coutinho Cardoso; David Normando
Journal:  Angle Orthod       Date:  2020-07-01       Impact factor: 2.079

Review 2.  A Scoping Review about the Characteristics and Success-Failure Rates of Temporary Anchorage Devices in Orthodontics.

Authors:  Daniel Jaramillo-Bedoya; Gustavo Villegas-Giraldo; Andrés A Agudelo-Suárez; Diana Milena Ramírez-Ossa
Journal:  Dent J (Basel)       Date:  2022-05-06

3.  Mechanical strength of stainless steel and titanium alloy mini-implants with different diameters: an experimental laboratory study.

Authors:  Sérgio Estelita Barros; Viviane Vanz; Kelly Chiqueto; Guilherme Janson; Eduardo Ferreira
Journal:  Prog Orthod       Date:  2021-03-22       Impact factor: 2.750

4.  Crystalline Biomimetic Calcium Phosphate Coating on Mini-Pin Implants to Accelerate Osseointegration and Extend Drug Release Duration for an Orthodontic Application.

Authors:  Menghong Li; Gang Wu; Mingjie Wang; Ernst B Hunziker; Yuelian Liu
Journal:  Nanomaterials (Basel)       Date:  2022-07-16       Impact factor: 5.719

  4 in total