Literature DB >> 20974446

Mechanical properties evaluation of an orthodontic miniscrew system for skeletal anchorage.

Daniele Francioli1, Grazia Ruggiero, Roberto Giorgetti.   

Abstract

OBJECTIVE: Orthodontic anchorage control is a fundamental chapter of a successful orthodontic therapy: mini-screws have been commonly used to increase absolute anchorage with no need for patient compliance, therefore reducing treatment time. The purpose of this study was to analyze the mechanical performance of a self-tapping surgical stainless steel mini-screw system.
MATERIALS AND METHODS: Data concerning the mechanical properties of a stainless steel mini-screw system subjected to torsional and flexural forces were collected. The sample consisted of 10 AISI 316LVM surgical stainless steel 1.5mm in diameter mini-screws and 10 surgical stainless steel 2mm in diameter mini-screws manufactured by Leone. The devices were inserted into a polyurethane block. Maximum torsional resistance was measured by a torque meter (series MG MARK-10); flexural strength was registered with a universal tester (series 4300 INSTRON), equipped with a 2518-809 5 kg load cell.
RESULTS: Torsional test: at a 26.5 N cm force magnitude yielding was observed on 1.5mm diameter mini-screws and at 48.3N cm on 2mm diameter mini-screws. Flexural test: 1.5mm diameter mini-screws plastically deformed with a loading value of 105,4N and 2mm diameter mini-screws deformed when load exceeded 216.7 N.
CONCLUSIONS: The evaluated surgical stainless steel mini-screw system withstood greater force magnitude compared to other commercially available mini-screw systems (titanium and titanium alloy); therefore the examined mini-screw system is provided with greater mechanical properties.
Copyright © 2010 Società Italiana di Ortodonzia SIDO. Published by Elsevier Srl. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20974446     DOI: 10.1016/j.pio.2010.04.014

Source DB:  PubMed          Journal:  Prog Orthod        ISSN: 1723-7785            Impact factor:   2.750


  4 in total

1.  Biomechanical strength analysis of mini anchors for the temporomandibular joint.

Authors:  Andrezza Lauria; Danillo Costa Rodrigues; Fábio Ricardo Loureiro Sato; Roger William Fernandes Moreira
Journal:  Oral Maxillofac Surg       Date:  2013-09-24

2.  Stainless steel or titanium mini-implants?

Authors:  Paulo Mecenas; Daybelis Gonzalez Espinosa; Paula Coutinho Cardoso; David Normando
Journal:  Angle Orthod       Date:  2020-07-01       Impact factor: 2.079

3.  Mechanical strength of stainless steel and titanium alloy mini-implants with different diameters: an experimental laboratory study.

Authors:  Sérgio Estelita Barros; Viviane Vanz; Kelly Chiqueto; Guilherme Janson; Eduardo Ferreira
Journal:  Prog Orthod       Date:  2021-03-22       Impact factor: 2.750

4.  Analysis of Torque Maintenance and Fracture Resistance after Fatigue in Retention Screws Made of Different Metals for Screw-Retained Implant-Borne Prosthesis Joints.

Authors:  Maria Beatriz Bello Taborda; Gabriela Sumie Yaguinuma Gonçalves; Cecília Alves de Sousa; Wirley Gonçalves Assunção
Journal:  Int J Dent       Date:  2021-11-18
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.