Absorption characteristics of human fetal hemoglobin at wavelengths used in pulse oximetry.

A P Harris1, M J Sendak, R T Donham, M Thomas, D Duncan.   

Abstract

The absorption characteristics of fetal and adult human hemoglobin samples were determined for the range of 600 to 1,050 nm. Over this range, fetal hemoglobin absorption is nearly identical to that of adult hemoglobin. Since currently available two-wavelength pulse oximeters base their calculations of arterial oxyhemoglobin saturation on absorption at the wavelengths of 660 and 920 nm, we conclude that the accuracy of two-wavelength pulse oximetry previously demonstrated in adults can be extrapolated to infants with high concentrations of fetal hemoglobin.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 2463343     DOI: 10.1007/bf01621812

Source DB:  PubMed          Journal:  J Clin Monit        ISSN: 0748-1977


  5 in total

1.  Accuracy of pulse oximetry during arterial oxyhemoglobin desaturation in dogs.

Authors:  M J Sendak; A P Harris; R T Donham
Journal:  Anesthesiology       Date:  1988-01       Impact factor: 7.892

2.  Directly measured arterial oxygen saturation in the newborn infant.

Authors:  C A Ryan; K J Barrington; D Vaughan; N N Finer
Journal:  J Pediatr       Date:  1986-09       Impact factor: 4.406

3.  Correction factors for hemoglobin derivatives in fetal blood, as measured with the IL 282 CO-Oximeter.

Authors:  P J Cornelissen; C L van Woensel; W C van Oel; P A de Jong
Journal:  Clin Chem       Date:  1983-08       Impact factor: 8.327

4.  Noninvasive arterial hemoglobin oxygen saturation versus transcutaneous oxygen tension monitoring in the preterm infant.

Authors:  R Deckardt; D J Steward
Journal:  Crit Care Med       Date:  1984-11       Impact factor: 7.598

5.  Pulse oximetry for continuous oxygen monitoring in sick newborn infants.

Authors:  M Durand; R Ramanathan
Journal:  J Pediatr       Date:  1986-12       Impact factor: 4.406

  5 in total
  11 in total

Review 1.  Hyperspectral imaging in diabetic foot wound care.

Authors:  Dmitry Yudovsky; Aksone Nouvong; Laurent Pilon
Journal:  J Diabetes Sci Technol       Date:  2010-09-01

Review 2.  Pulse oximetry.

Authors:  J F Kelleher
Journal:  J Clin Monit       Date:  1989-01

3.  Validation of oxygen saturation monitoring in neonates.

Authors:  Shyang-Yun Pamela K Shiao; Ching-Nan Ou
Journal:  Am J Crit Care       Date:  2007-03       Impact factor: 2.228

4.  Pulse oximetry reference values at high altitude.

Authors:  J M Lozano; O R Duque; T Buitrago; S Behaine
Journal:  Arch Dis Child       Date:  1992-03       Impact factor: 3.791

Review 5.  Uses and abuses of pulse oximetry.

Authors:  J T Moyle
Journal:  Arch Dis Child       Date:  1996-01       Impact factor: 3.791

6.  Assessing diabetic foot ulcer development risk with hyperspectral tissue oximetry.

Authors:  Dmitry Yudovsky; Aksone Nouvong; Kevin Schomacker; Laurent Pilon
Journal:  J Biomed Opt       Date:  2011-02       Impact factor: 3.170

Review 7.  Hemoglobin oxygen saturation targets in the neonatal intensive care unit: Is there a light at the end of the tunnel? 1.

Authors:  Payam Vali; Mark Underwood; Satyan Lakshminrusimha
Journal:  Can J Physiol Pharmacol       Date:  2018-10-26       Impact factor: 2.273

8.  Hydroyxurea improves cerebral oxygen saturation in children with sickle cell anemia.

Authors:  Kristine Karkoska; Charles T Quinn; Omar Niss; Amanda Pfeiffer; Min Dong; Alexander A Vinks; Patrick T McGann
Journal:  Am J Hematol       Date:  2021-02-19       Impact factor: 10.047

Review 9.  Oxygen targeting in preterm infants: a physiological interpretation.

Authors:  S Lakshminrusimha; V Manja; B Mathew; G K Suresh
Journal:  J Perinatol       Date:  2014-10-30       Impact factor: 2.521

10.  Racial discrepancy in pulse oximeter accuracy in preterm infants.

Authors:  Zachary Vesoulis; Anna Tims; Hafsa Lodhi; Natasha Lalos; Halana Whitehead
Journal:  J Perinatol       Date:  2021-10-12       Impact factor: 3.225

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.