Literature DB >> 12889721

Accuracy of pulse oximetry and capnography in healthy and compromised horses during spontaneous and controlled ventilation.

Judith Koenig1, Wayne McDonell, Alexander Valverde.   

Abstract

The objective of this prospective clinical study was to evaluate the accuracy of pulse oximetry and capnography in healthy and compromised horses during general anesthesia with spontaneous and controlled ventilation. Horses anesthetized in a dorsal recumbency position for arthroscopy (n = 20) or colic surgery (n = 16) were instrumented with an earlobe probe from the pulse oximeter positioned on the tip of the tongue and a sample line inserted at the Y-piece for capnography. The horses were allowed to breathe spontaneously (SV) for the first 20 min after induction, and thereafter ventilation was controlled (IPPV). Arterial blood, for blood gas analysis, was drawn 20 min after induction and 20 min after IPPV was started. Relationships between oxygen saturation as determined by pulse oximetry (SpO2), arterial oxygen saturation (SaO2), arterial carbon dioxide partial pressure (PaCO2), and end tidal carbon dioxide (P(et)CO2), several physiological variables, and the accuracy of pulse oximetry and capnography, were evaluated by Bland-Altman or regression analysis. In the present study, both SpO2 and P(et)CO2 provided a relatively poor indication of SaO2 and PaCO2, respectively, in both healthy and compromised horses, especially during SV. A difference in heart rate obtained by pulse oximetry, ECG, or palpation is significantly correlated with any pulse oximeter inaccuracy. If blood gas analysis is not available, ventilation to P(et)CO2 of 35 to 45 mmHg should maintain the PaCO2 within a normal range. However, especially in compromised horses, it should never substitute blood gas analysis.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12889721      PMCID: PMC227048     

Source DB:  PubMed          Journal:  Can J Vet Res        ISSN: 0830-9000            Impact factor:   1.310


  26 in total

1.  [Capnography--a method for evaluating the ventilation level in general anesthesia in the horse].

Authors:  K Otto
Journal:  Zentralbl Veterinarmed A       Date:  1986-10

2.  [Pulse oximetry--a non-invasive method for direct and continuous monitoring of oxygen saturation and pulse rate--comparative studies with blood gas analysis and hemoreflectometry in the dog, swine and sheep].

Authors:  W Erhardt; C Lendl; R Hipp; M Schindele; G Blümel
Journal:  Berl Munch Tierarztl Wochenschr       Date:  1989-09-01       Impact factor: 0.328

3.  Pulse oximetry in horses.

Authors:  K J Whitehair; G C Watney; D E Leith; R M Debowes
Journal:  Vet Surg       Date:  1990 May-Jun       Impact factor: 1.495

4.  The effect of changing the mode of ventilation on the arterial-to-end-tidal CO2 difference and physiological dead space in laterally and dorsally recumbent horses during halothane anesthesia.

Authors:  F J Neto; S P Luna; F Massone; A Thomassian; J L Vargas; J R Junior; B B D'Utra Vaz; A J Crocci
Journal:  Vet Surg       Date:  2000 Mar-Apr       Impact factor: 1.495

Review 5.  Blood-gas equilibrium of carbon dioxide in lungs: a continuing controversy.

Authors:  J Piiper
Journal:  J Appl Physiol (1985)       Date:  1986-01

6.  Acid-base and blood gas studies in horses. II. Tracheal end-tidal and arterial blood gas tensions in horses.

Authors:  A Littlejohn
Journal:  Res Vet Sci       Date:  1969-05       Impact factor: 2.534

7.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

8.  Prevention of endotoxin-induced arterial hypoxaemia and lactic acidosis with flunixin meglumine in the conscious pony.

Authors:  J N Moore; H E Garner; J E Shapland; D G Hatfield
Journal:  Equine Vet J       Date:  1981-04       Impact factor: 2.888

9.  Arterial to end-tidal CO2 tension and alveolar dead space in halothane- or isoflurane-anesthetized ponies.

Authors:  R E Meyer; C E Short
Journal:  Am J Vet Res       Date:  1985-03       Impact factor: 1.156

10.  The concept of deadspace with special reference to the single breath test for carbon dioxide.

Authors:  R Fletcher; B Jonson; G Cumming; J Brew
Journal:  Br J Anaesth       Date:  1981-01       Impact factor: 9.166

View more
  2 in total

1.  The role of pulse oximetry in chiropractic practice: a rationale for its use.

Authors:  Michael W Hall; Anne M Jensen
Journal:  J Chiropr Med       Date:  2012-06

2.  Use of Electrical Impedance Tomography (EIT) to Estimate Tidal Volume in Anaesthetized Horses Undergoing Elective Surgery.

Authors:  Benedetta Crivellari; Anthea Raisis; Giselle Hosgood; Andreas D Waldmann; David Murphy; Martina Mosing
Journal:  Animals (Basel)       Date:  2021-05-10       Impact factor: 2.752