Laura Fraeulin1, Fabian Holzgreve1, Mark Brinkbäumer2, Anna Dziuba2, David Friebe2, Stefanie Klemz2, Marco Schmitt2, Anna-Lena Theis A2, Sarah Tenberg2, Anke van Mark1, Christian Maurer-Grubinger1, Daniela Ohlendorf1.
Abstract
BACKGROUND: In clinical practice range of motion (RoM) is usually assessed with low-cost devices such as a tape measure (TM) or a digital inclinometer (DI). However, the intra- and inter-rater reliability of typical RoM tests differ, which impairs the evaluation of therapy progress. More objective and reliable kinematic data can be obtained with the inertial motion capture system (IMC) by Xsens. The aim of this study was to obtain the intra- and inter-rater reliability of the TM, DI and IMC methods in five RoM tests: modified Thomas test (DI), shoulder test modified after Janda (DI), retroflexion of the trunk modified after Janda (DI), lateral inclination (TM) and fingertip-to-floor test (TM).Entities:
Year: 2020 PMID: 33301541 PMCID: PMC7728246 DOI: 10.1371/journal.pone.0243646
Source DB: PubMed Journal: PLoS One ISSN: 1932-6203 Impact factor: 3.240
Fig 1The range of motion measurements.
a) Shoulder test modified after Janda on the left-hand body side, b) modified Thomas test on the left-hand body side, c) retroflexion of the trunk after Janda in the modified version, d) fingertip-to-floor test and e) lateral inclination on the right-hand body side. The measurements were simultaneously recorded in the Xsens system (subjects wears the measurement suit) and the low cost devices.
Intra-rater reliability for both raters using the DI and TM.
| DI/TM | Thomas test | Shoulder test | Retroflexion | Lateral Inclination | Fingertip-to-floor | ||||
|---|---|---|---|---|---|---|---|---|---|
| Measuring system | DI | DI | DI | TM | TM | ||||
| Body side | left | right | left | right | ------ | left | right | ------- | |
| Rater | |||||||||
| ICC | Rater 1 | 0.976 | 0.987 | 0.942 | 0.945 | 0.914 | 0.887 | 0.975 | 0.965 |
| Rater 2 | 0.962 | 0.955 | 0.925 | 0.947 | 0.886 | 0.974 | 0.962 | 0.951 | |
| 95% Confidence Interval | Rater 1 | [0.95; 0.99] | [0.97; 0.99] | [0.90; 0.98] | [0.91; 0.98] | [0.86; 0.97] | [0.82; 0.96] | [0.96; 0.99] | [0.94; 0.98] |
| Rater 2 | [0.93; 0.98] | [0.92; 0.98] | [0.88; 0.97] | [0.91; 0.98] | [0.82; 0.95] | [0.96; 0.99] | [0.94; 0.99] | [0.92; 0.98] | |
| P-value | Rater 1 | 0.001 | 0.001 | 0.001 | 0.001 | >0.001 | >0.001 | >0.001 | >0.001 |
| Rater 2 | 0.001 | 0.001 | 0.001 | 0.001 | >0.001 | >0.001 | >0.001 | >0.001 | |
| ME | Rater 1 | 0.9° | 0.9° | 1.8° | 2.2° | 2.7° | 1.1 cm | 0.6 cm | 1.1 cm |
| Rater 2 | 1.1° | 1.4° | 2° | 2.2° | 3.3° | 0.5 cm | 0.8 cm | 1.3 cm | |
| Repeatability | Rater 1 | 1.6° | 2° | 2.6° | 3.1° | 3.8° | 1.6 cm | 0.9 cm | 1.5 cm |
| Rater 2 | 1.3° | 1.2° | 2.9° | 3.1° | 4.7° | 0.7 cm | 1.1 cm | 1.9 cm | |
| CoR | Rater 1 | 3.1° | 3.9° | 5.1° | 6.1° | 7.5° | 3.1 cm | 1.8 cm | 2.9 cm |
| Rater 2 | 2.4° | 2.4° | 5.7° | 6.1° | 9.2° | 1.4 cm | 2.2 cm | 3.7 cm | |
DI = digital inclinometer; TM = tape measure; IMC = inertial motion capture; ME = measurement error; CoR = coefficient of repeatability.
ICCs were rounded to three digits after the decimal point when ICCs lay between 0.899–1.00 to show that they were still below 1. The units for measurement error, repeatability and CoR are centimeters where a TM was used and degree° where a DI was used.
Intra-rater reliability for both raters using the IMC.
| IMC | Thomas test | Shoulder test | Retroflexion | Lateral Inclination | Fingertip-to-floor | ||||
|---|---|---|---|---|---|---|---|---|---|
| Measuring system | DI | DI | DI | TM | TM | ||||
| Body side | left | right | left | right | ------ | left | right | ------- | |
| Rater | |||||||||
| ICC | Rater 1 | 0.996 | 0.990 | 0.921 | 0.970 | 0.972 | 0.985 | 0.924 | 0.958 |
| Rater 2 | 0.994 | 0.982 | 0.899 | 0.938 | 0.974 | 0.984 | 0.942 | 0.921 | |
| 95% Confidence Interval | Rater 1 | [0.99; 1.00] | [0.98; 1.00] | [0.87; 0.97] | [0.95; 0.99] | [0.95; 0.99] | [0.98; 0.99] | [0.88; 0.97] | [0.93; 0.98] |
| Rater 2 | [0.99; 1.00] | [0.97; 0.99] | [0.83; 0.97] | [0.90; 0.98] | [0.96; 0.99] | [0.97; 0.99] | [0.91; 0.98] | [0.87; 0.97] | |
| P-value | Rater 1 | >0.001 | >0.001 | >0.001 | >0.001 | >0.001 | >0.001 | >0.001 | >0.001 |
| Rater 2 | >0.001 | >0.001 | >0.001 | >0.001 | >0.001 | >0.001 | >0.001 | >0.001 | |
| ME | Rater 1 | 0.5° | 0.7° | 1.5° | 1.3° | 1.1° | 0.6 cm | 1.6 cm | 2.2 cm |
| Rater 2 | 0.7° | 1.1° | 1.6° | 2° | 1.2° | 0.7 cm | 1.5 cm | 2.7 cm | |
| Repeatability | Rater 1 | 0.7° | 1° | 2° | 1.9° | 1.5° | 0.9 cm | 2.2 cm | 3.1 cm |
| Rater 2 | 1° | 1.6° | 2.3° | 2.8° | 1.6° | 1 cm | 2.2 cm | 3.9 cm | |
| CoR | Rater 1 | 1.4° | 2° | 3.9° | 3.7° | 2.9° | 1.8 cm | 4.3 cm | 6.1 cm |
| Rater 2 | 2° | 3.1° | 4.5° | 5.5° | 3.1° | 2 cm | 4.3 cm | 7.6 cm | |
DI = digital inclinometer; TM = tape measure; IMC = inertial motion capture; ME = measurement error; CoR = coefficient of repeatability.
ICCs were rounded to three digits after the decimal point when the ICCs lay between 0.899–1.00 to show that they were still below 1. The units for measurement error, repeatability and CoR are centimeters where a TM was used and degree° where a DI was used.
Inter-rater reliability for using the TM and DI.
| Inter-rater Reliability | Thomas test | Shoulder test | Retroflexion | Lateral Inclination | Fingertip-to-floor | ||||
|---|---|---|---|---|---|---|---|---|---|
| Measuring system | DI | DI | DI | TM | TM | ||||
| Body side | left | right | left | right | ------ | left | right | ------- | |
| Rater | |||||||||
| ICC | DI/TM | 0.87 | 0.72 | 0.80 | 0.71 | 0.84 | 0.961 | 0.938 | 0.923 |
| IMC | 0.86 | 0.78 | 0.61 | 0.81 | 0.910 | 0.993 | 0.975 | 0.965 | |
| 95% Confidence Interval | DI/TM | [0.77; 0.96] | [0.55. 0.85] | [0.57; 0.91] | [0.43; 0.88] | [0.66; 0.93] | [0.91; 0.98] | [0.86; 0.97] | [0.82; 0.97] |
| IMC | [0.69; 0.94] | [0.55; 0.90] | [0.21; 0.83] | [0.58; 0.92] | [0.79; 0.96] | [0.98; 1.00] | [0.94; 0.99] | [0.92; 0.99] | |
| P-value | DI/TM | 0.001 | 0.001 | 0.001 | 0.001 | >0.001 | >0.001 | >0.001 | >0.001 |
| IMC | >0.001 | >0.001 | 0.003 | >0.001 | >0.001 | >0.001 | >0.001 | >0.001 | |
DI = digital inclinometer; TM = tape measure; IMC = inertial motion capture; ME = measurement error.
ICCs were rounded to three digits after the decimal point when the ICCs lay between 0.899–1.00 to show that they were still below 1.
Fig 2The relationship between the low cost device methods and the IMC method.
Here the means of the last five measurements of rater 1 were used for the plot.
Pearson correlations between the DI–IMC or TM–IMC measurement systems.
| Correlations | Thomas test | Shoulder test | Retroflexion | Lateral Inclination | Fingertip-to-floor | |||
|---|---|---|---|---|---|---|---|---|
| Body side | left | right | left | right | ------ | left | right | ------- |
| Measurement Systems | DI—IMC | DI—IMC | DI—IMC | DI—IMC | DI—IMC | TM—IMC | TM—IMC | TM—IMC |
| Correlation Coefficient (r) | 0.49* | 0.53* | 0.54* | 0.41 | 0.52* | 0.79* | 0.73* | 0.81* |
| n | 21 | 20 | 19 | 20 | 21 | 20 | 22 | 22 |
DI = digital inclinometer; TM = tape measure; IMC = inertial motion capture.
The 21st repetition of rater 1 was used exemplarily; only measurements where synchronicity could be ensured were included. Statistical significance is indicated by *.
Summary of the correlations, intra- and inter-rater reliabilities.
| Summary | Thomas test | Shoulder test | Retroflexion | Lateral Inclination | Fingertip-to-floor | ||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Meas. system | DI | IMC | DI | IMC | DI | IMC | TM | IMC | TM | IMC | |
| Body side | |||||||||||
| left | moderate | moderate | moderate | strong | optimal | ||||||
| right | |||||||||||
| left | (almost) perfect | ||||||||||
| right | |||||||||||
| left | (almost) perfect | substantial | substantial | (almost) perfect | (almost) perfect | (almost) perfect | |||||
| right | substantial | (almost) perfect | |||||||||
DI = digital inclinometer; TM = tape measure; IMC = inertial motion capture.