Purpose: The purpose of this study was to evaluate the association of 24-hour intraocular pressure (IOP) fluctuation with corneal biomechanics and ocular biometric parameters in Chinese patients with primary open angle glaucoma (POAG) before initial treatment.Entities:
Keywords: axial length (AL); corneal hysteresis (CH); glaucoma; intraocular pressure fluctuation (IOP)
Mesh:
Year: 2020 PMID: 33244445 PMCID: PMC7683862 DOI: 10.1167/tvst.9.12.25
Source DB: PubMed Journal: Transl Vis Sci Technol ISSN: 2164-2591 Impact factor: 3.283
Demographic Data, Corneal Biomechanical, and Ocular Biometric Parameters
| Parameters | Mean ± SD | Range |
|---|---|---|
| Subjects (eyes) | 49 (98) | / |
| OD: OS | 49: 49 | / |
| NTG: HTG subjects (eyes) | 27 (54): 22 (44) | / |
| Sex (female : male) | 20 (40): 29 (58) | / |
| Age | 54.26 ± 14.54 | 26–82 |
| Initial IOP, mm Hg | 17.73 ± 2.97 | 13–26 |
| IOP fluctuation, mm Hg | 7.32 ± 2.64 | 2.1–14.4 |
| Relative fluctuation % | 44.54 ± 14.83 | 12.62–99.42 |
| Mean circadian IOP, mm Hg | 16.55 ± 3.31 | 10.87–24.13 |
| IOPcc, mm Hg | 18.42 ± 3.58 | 11.45–27.5 |
| IOPg, mm Hg | 18.01 ± 3.79 | 10.53–28 |
| CH, mm Hg | 10.14 ± 1.11 | 7.96–13.8 |
| CRF, mm Hg | 10.94 ± 1.41 | 8.23–14.51 |
| CCT, µm | 539.38 ± 34.25 | 476–616 |
| Axial length, mm | 25.61 ± 2.15 | 22.21–31.02 |
| Mean Deviation, dB | 8.07 ± 5.38 | 2.2–22.6 |
| RNFL thickness, µm | 81.42 ± 11.83 | 57.67–108.99 |
IOP, intraocular pressure; IOP fluctuation, Diurnal IOP maximum to IOP minimum; the relative fluctuation %, IOP fluctuation/mean IOP; IOPcc, corneal-compensated intraocular pressure; IOPg, Goldmann-correlated intraocular pressure; CH, corneal hysteresis; CRF, corneal resistance factor; CCT, central corneal thickness.
Data are shown as mean ± SD.
Figure.The 24-hour intraocular pressure patterns of the patients with POAG, HTG, and NTG before initial treatment. The 24-hour IOP was measured by a noncontact tonometer. The IOP of both eyes was measured every 2 hours from 8:00 AM to 6:00 AM the next day, specifically at 8:00 AM, 10:00 AM, 12:00 PM, 2:00 PM, 4:00 PM, 6:00 PM, 8:00 PM, and 10:00 PM (diurnal period IOP) and at 12:00 AM, 2:00 AM, 4:00 AM, and 6:00 AM (nocturnal period IOP). The IOP was highest at 6:00 to 8:00 AM, and gradually decreased along the diurnal period, then reached the lowest at 8:00 PM. The IOP progressively increased again along the nocturnal period. HTG, subjects with high tension glaucoma; NTG, subjects with normal tension glaucoma; NTG + HTG: subjects with normal tension glaucoma or high-tension glaucoma.
Risk Factors Associated With Intraocular Pressure Fluctuation in Multivariable Analysis
| Model 1 | Model 2 | |||
|---|---|---|---|---|
| Parameters | β Coefficient (SE) |
| β Coefficient (SE) |
|
| Axial length (AL) | −0.454 (0.138) |
| −0.401 (0.157) |
|
| Central corneal thickness (CCT, µm) | −0.003 (0.010) | 0.784 | 0.009 (0.014) | 0.524 |
| Corneal hysteresis (CH, mm Hg) | −0.298 (0.252) | 0.238 | −0.180 (0.305) | 0.554 |
| Corneal resistance factor (CRF, mm Hg) | 0.191 (0.236) | 0.417 | −0.022 (0.384) | 0.953 |
| Goldmann-correlated IOP (IOPg, mm Hg) | 0.160 (0.067) |
| 0.186 (0.118) | 0.116 |
Comparison of the Intraocular Pressure and Ocular Structure Parameters Between the Shorter and Longer Axial Length Group
| Axial Length < = 26 mm ( | Axial Length > 26 mm ( | ||
|---|---|---|---|
| Parameters | Mean ± SD (Range) | Mean ± SD (Range) | |
| Initial IOP, mm Hg | 18.44 ± 3.21 (13–26) | 16.71 ± 2.33 (13–22) | |
| IOP fluctuation, mm Hg | 7.73 ± 2.51 (2.5–14.4) | 6.56 ± 2.30 (2.1–14.8) | |
| Relative fluctuation % | 46.28 ± 14.21 (21.71–99.42) | 42.19 ±15.49 (12.62–77.12) | 0.196 |
| Mean circadian IOP, mm Hg | 16.97 ± 3.45 (10.87–24.13) | 15.99 ± 3.06 (11.73–23.05) | 0.16 |
| IOPcc, mm Hg | 19.32 ± 3.69 (11.86–27.5) | 17.04 ± 2.92 (11.45–25.48) | |
| IOPg, mm Hg | 18.82 ± 3.95 (11.5–28) | 16.81 ± 3.28 (10.53–25.18) | |
| CH, mm Hg | 9.96 ± 1.05 (8.29–13.49) | 10.46 ± 1.10 (8.59–13.8) | |
| CRF, mm Hg | 11.03 ± 1.41 (8.23–14) | 10.86 ± 1.44 (8.91–14.51) | 0.27 |
| CCT, µm | 533.68 ± 35.03 (482–614) | 549.98 ± 28.88 (496–616) | 0.054 |
IOP, intraocular pressure; IOP fluctuation, diurnal IOP maximum to IOP minimum; the relative fluctuation %, IOP fluctuation/mean IOP; CCT, central corneal thickness; IOPcc, corneal-compensated intraocular pressure; IOPg, Goldmann-correlated intraocular pressure; CH, corneal hysteresis; CRF, corneal resistance factor.
P values were adjusted for age and gender. Data are shown as mean ± SD. P values were in bold face if < 0.05.
Comparison of the Intraocular Pressure and Ocular Structure Parameters Between Patients with NTG and HTG
| NTG ( | HTG ( | ||
|---|---|---|---|
| Parameters | Mean ± SD (Range) | Mean ± SD (Range) | |
| Initial IOP, mm Hg | 16.39 ± 2.18 (13–21) | 19.30 ± 3.02 (13–26) | |
| IOP fluctuation, mm Hg | 6.12 ± 2.35 (2.1–14.4) | 8.93 ± 2.12 (5–14.8) | |
| Relative fluctuation % | 43.1 ± 16.73 (12.62–99.42) | 46.49 ± 11.72 (26.2–77.12) | 0.281 |
| Mean circadian IOP, mm Hg | 14.44 ± 2.14 (10.87–20.65) | 19.41 ± 2.32 (14.93–24.13) | |
| Axial length | 26.01 ± 2.37 (22.69–31.02) | 24.97 ± 1.72 (22.21–28.91) | |
| IOPcc, mm Hg | 16.78 ± 2.26 (11.45–20.44) | 20.35 ± 3.89 (11.86–27.5) | |
| IOPg, mm Hg | 16.13 ± 2.33 (10.53–19.52) | 20.21 ± 4 (11.66–28) | |
| CH, mm Hg | 10.17 ± 1.02 (8.59–13.8) | 10.11 ± 1.23 (7.96–13.49) | 0.819 |
| CRF, mm Hg | 10.40 ± 1.13 (8.23–14.51) | 11.58 ± 1.45 (9.48–14.36) | |
| CCT, µm | 535.28 ± 33.34 (482–616) | 544.20 ± 35.04 (476–614) | 0.201 |
IOP, intraocular pressure; IOP fluctuation, diurnal IOP maximum to IOP minimum; the relative fluctuation %, IOP fluctuation/mean IOP; CCT, central corneal thickness; IOPcc, corneal-compensated intraocular pressure; IOPg, Goldmann-correlated intraocular pressure; CH, corneal hysteresis; CRF, corneal resistance factor; HTG, high tension glaucoma; NTG, normal tension glaucoma.
P values were adjusted for age and gender. Data are shown as mean ± SD. P values were bold face if < 0.05.