| Literature DB >> 33223698 |
Mohammed Samiuddin Ahmed1, Kareti Mahendranadh Reddy1, Y Mahadev Shastry1, S Venkat Aditya1, P Jayakrishna Babu1.
Abstract
AIM: The aim of this study is to evaluate the flexural strength of zirconia using three different connector designs under vertical and oblique loads. SETTING ANDEntities:
Keywords: Connector; fixed partial denture; fixed prosthesis; zirconia
Year: 2020 PMID: 33223698 PMCID: PMC7654207 DOI: 10.4103/jips.jips_68_20
Source DB: PubMed Journal: J Indian Prosthodont Soc ISSN: 0972-4052
Figure 1Schematic diagram of the round connector specimen
Figure 3Schematic diagram of the triangle connector specimen
Statistical analysis of vertical loads, one-way ANOVA, Bonferroni’s post hoc test
| Mean | SD | SE | 95% CI for mean | Minimum-maximum | |||||
|---|---|---|---|---|---|---|---|---|---|
| Lower bound | Upper bound | ||||||||
| Round vertical | 10 | 1438.00 | 235.94 | 74.61 | 1269.22 | 1606.78 | 1180-1960 | <0.01 | 1, 2>3 |
| Triangle veritcal | 10 | 1478.80 | 215.26 | 68.07 | 1324.81 | 1632.79 | 1053-1800 | ||
| Oval vertical | 10 | 1095.60 | 133.44 | 42.20 | 1000.15 | 1191.05 | 928-1320 | ||
| Total | 30 | 1337.47 | 260.24 | 47.51 | 1240.29 | 1434.64 | 928-1960 | ||
SD: Standard deviation, SE: Standard error, CI: Confidence interval
Statistical analysis of oblique loads, one-way ANOVA, Bonferroni’s post hoc test
| Mean | SD | SE | 95% CI for mean | Minimum-maximum | Significant | ||||
|---|---|---|---|---|---|---|---|---|---|
| Lower bound | Upper bound | ||||||||
| Round oblique | 10 | 1393.20 | 265.744 | 84.036 | 1203.10 | 1583.30 | 1018-1858 | <0.01 | 1>2, 3 |
| Triangle oblique | 10 | 931.00 | 158.089 | 49.992 | 817.91 | 1044.09 | 705-1138 | ||
| Oval oblique | 10 | 1119.10 | 243.325 | 76.946 | 945.04 | 1293.16 | 828-1468 | ||
| Total | 30 | 1147.77 | 292.070 | 53.324 | 1038.71 | 1256.83 | 705-1858 | ||
SD: Standard deviation, SE: Standard error, CI: Confidence interval
Kruskal-Wallis ANOVA, Mann-Whitney post hoc tests for vertical loads
| Vertical load | Minimum | Maximum | Mean | SD | |||
|---|---|---|---|---|---|---|---|
| Round | 10 | 1180 | 1960 | 1438 | 235.94 | 0.008 | 1, 2>3 |
| Triangle (2) | 10 | 1053 | 1800 | 1478 | 215.26 | ||
| Oval (3) | 10 | 928 | 1320 | 1095 | 133.44 |
SD: Standard deviation
Kruskal-Wallis ANOVA, Mann-Whitney post hoc tests for oblique loads
| Oblique load | Minimum | Maximum | Mean | SD | |||
|---|---|---|---|---|---|---|---|
| Round | 10 | 1018 | 1858 | 1348.10 | 265.74 | 0.033 | 1>2, 3 |
| Triangle | 10 | 705 | 1138 | 991.00 | 158.08 | ||
| Oval | 10 | 828 | 1468 | 1119.10 | 243.32 |
SD: Standard deviation
Figure 4Diagramatic representation of the octagonal cylinder
Figure 5Arrows showing the connector in milled zirconia specimen
Figure 6Diagramatic representation of triangle shaped cylinder