Literature DB >> 19496928

Clinical performance of extended zirconia frameworks for fixed dental prostheses: two-year results.

M Schmitter1, K Mussotter, P Rammelsberg, T Stober, B Ohlmann, O Gabbert.   

Abstract

The purpose of this prospective cohort study was to assess the performance of tooth-supported, extended zirconia, fixed dental prostheses (FDPs). Thirty FDPs with span-lengths between 36 and 46 mm (mean: 40.33 mm), four to seven units and with connector dimensions of approximately 9 mm(2) were inserted (19 in the posterior region, 11 including anterior teeth) using glass-ionomer cement and assessed (aesthetic evaluation, failures, hypersensitivity/tooth vitality, secondary caries, pocket depth, decementation and chipping) at baseline and after 2 years. Differences between baseline and 2-year recall were analysed using the Wilcoxon signed-rank test for matched pairs. There were five failures. One FDP revealed a core fracture at the base of the connector, probably caused by a damage induced during fabrication. Two FDPs had to be recemented, one abutment tooth had to be treated endodontically and one cohesive failure of the veneer was observed. There were no significant changes of pocket depth and hypersensitivity between baseline and 2-year recall. The aesthetics were rated as excellent by the patients at both baseline and recall. Two year clinical results of extended zirconia based FDPs with 9 mm(2) connectors are promising.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19496928     DOI: 10.1111/j.1365-2842.2009.01969.x

Source DB:  PubMed          Journal:  J Oral Rehabil        ISSN: 0305-182X            Impact factor:   3.837


  17 in total

1.  Overview: Damage resistance of graded ceramic restorative materials.

Authors:  Yu Zhang
Journal:  J Eur Ceram Soc       Date:  2012-08-01       Impact factor: 5.302

2.  Tooth-implant-supported posterior fixed dental prostheses with zirconia frameworks: 3-year clinical result.

Authors:  Florian Beuer; Caroline Sachs; Julian Groesser; Jan-Frederik Gueth; Michael Stimmelmayr
Journal:  Clin Oral Investig       Date:  2015-09-24       Impact factor: 3.573

3.  Sliding contact fatigue of graded zirconia with external esthetic glass.

Authors:  L Ren; M N Janal; Y Zhang
Journal:  J Dent Res       Date:  2011-06-10       Impact factor: 6.116

4.  Comparison of implant versus tooth-supported zirconia-based single crowns in a split-mouth design: a 4-year clinical follow-up study.

Authors:  Mustafa Barış Güncü; Umut Cakan; Guliz Aktas; Güliz Nigar Güncü; Şenay Canay
Journal:  Clin Oral Investig       Date:  2016-02-29       Impact factor: 3.573

Review 5.  New Knowledge about Zirconium-Ceramic as a Structural Material in Fixed Prosthodontics.

Authors:  Davor Špehar; Marko Jakovac
Journal:  Acta Stomatol Croat       Date:  2015-06

6.  Five-year prospective clinical study of posterior three-unit zirconia-based fixed dental prostheses.

Authors:  Roberto Sorrentino; Giorgio De Simone; Stefano Tetè; Simona Russo; Fernando Zarone
Journal:  Clin Oral Investig       Date:  2011-06-11       Impact factor: 3.573

Review 7.  Dental Ceramics for Restoration and Metal Veneering.

Authors:  Yu Zhang; J Robert Kelly
Journal:  Dent Clin North Am       Date:  2017-10

8.  The influence of various core designs on stress distribution in the veneered zirconia crown: a finite element analysis study.

Authors:  Seung-Ryong Ha; Sung-Hun Kim; Jung-Suk Han; Seung-Hyun Yoo; Se-Chul Jeong; Jai-Bong Lee; In-Sung Yeo
Journal:  J Adv Prosthodont       Date:  2013-05-30       Impact factor: 1.904

9.  Clinical Outcomes and Predictors of Satisfaction in Patients with Improved Lithium Disilicate All-Ceramic Crowns.

Authors:  Mazin Saleh Samer; Qahtani Faraz; Sami Abdo Radman Al-Dubai; Fahim Vohra; Hadijah Abdullah; Tara Bai Taiyeb-Ali; Roslan Saub
Journal:  Med Princ Pract       Date:  2017-10-01       Impact factor: 1.927

10.  Technical and Biological Complications of Screw-Retained (CAD/CAM) Monolithic and Partial Veneer Zirconia for Fixed Dental Prostheses on Posterior Implants Using a Digital Workflow: A 3-Year Cross-Sectional Retrospective Study.

Authors:  Paolo De Angelis; Giulio Gasparini; Francesca Camodeca; Silvio De Angelis; Margherita Giorgia Liguori; Edoardo Rella; Francesca Cannata; Antonio D'Addona; Paolo Francesco Manicone
Journal:  Biomed Res Int       Date:  2021-07-06       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.