Fracture strength of four-unit Y-TZP FPD cores designed with varying connector diameter. An in-vitro study.

C Larsson1, L Holm, N Lövgren, Y Kokubo, P Vult von Steyern.   

Abstract

Reported clinical success rates of all-ceramic fixed partial dentures (FPDs) made of high-strength oxide ceramics range between 82.5% and 100%. The main cause of all-ceramic FPD failure is fracture in the connector area. There is, however, no consensus on what connector dimensions are adequate. The aim of this in-vitro study was, therefore, to compare the fracture strength of four-unit Y-TZP FPD cores designed with different connector diameters. A total of 40 four-unit FPD cores supported by end abutments and having two pontics were manufactured in Procera Zirconia. Five groups of FPD cores with connector dimensions of 2.0, 2.5, 3.0, 3.5 and 4.0 mm were produced. All FPD cores underwent a firing programme according to the manufacturer's recommendations for the veneering porcelain, a cyclic preload, thermocycling and finally, load until fracture. Fracture strength was significantly higher for each increase in connector diameter except for the 2.0-mm and 2.5-mm diameters where all fractures occurred during preload. All FPD cores fractured in the connector area. Within the limitations of this in-vitro study, a minimum diameter of 4.0 mm is recommended for all-ceramic zirconia-based FPDs with long spans or replacing molars. Clinical studies are, however, needed to determine adequate connector dimensions.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17716270     DOI: 10.1111/j.1365-2842.2007.01770.x

Source DB:  PubMed          Journal:  J Oral Rehabil        ISSN: 0305-182X            Impact factor:   3.837


  11 in total

1.  Strength of zirconia fixed partial dentures: review of the literature.

Authors:  M Gargari; F Gloria; A Cappello; L Ottria
Journal:  Oral Implantol (Rome)       Date:  2011-01-23

2.  Five-year prospective clinical study of posterior three-unit zirconia-based fixed dental prostheses.

Authors:  Roberto Sorrentino; Giorgio De Simone; Stefano Tetè; Simona Russo; Fernando Zarone
Journal:  Clin Oral Investig       Date:  2011-06-11       Impact factor: 3.573

3.  Effect of ceramic infrastructure on the failure behavior and stress distribution of fixed partial dentures.

Authors:  Márcia Borba; Yuanyuan Duan; Jason A Griggs; Paulo F Cesar; Álvaro Della Bona
Journal:  Dent Mater       Date:  2015-02-02       Impact factor: 5.304

4.  A Novel Design Modification to Improve Flexural Strength of Zirconia Framework: A Comparative Experimental In Vitro Study.

Authors:  Rajesh Shetty; Shifa Shoukath; Naresh H G Shetty; Sanath K Shetty; Savita Dandekeri; Mallikarjuna Ragher
Journal:  J Pharm Bioallied Sci       Date:  2020-08-28

5.  Fracture resistance and failure mode of posterior fixed dental prostheses fabricated with two zirconia CAD/CAM systems.

Authors:  Carlos López-Suárez; Esther Gonzalo; Jesús Peláez; Verónica Rodríguez; María-Jesús Suárez
Journal:  J Clin Exp Dent       Date:  2015-04-01

6.  Randomized clinical trial of implant-supported ceramic-ceramic and metal-ceramic fixed dental prostheses: preliminary results.

Authors:  Josephine F Esquivel-Upshaw; Arthur E Clark; Jonathan J Shuster; Kenneth J Anusavice
Journal:  J Prosthodont       Date:  2013-06-12       Impact factor: 2.752

7.  Fracture behavior of all-ceramic, implant-supported, and tooth-implant-supported fixed dental prostheses.

Authors:  Abdul Rahman Alkharrat; Marc Schmitter; Stefan Rues; Peter Rammelsberg
Journal:  Clin Oral Investig       Date:  2017-12-02       Impact factor: 3.573

8.  The zirconia ceramic: strengths and weaknesses.

Authors:  Elie E Daou
Journal:  Open Dent J       Date:  2014-04-18

9.  Evaluation of flexural strength of Zirconia using three different connector designs: An in vitro study.

Authors:  Mohammed Samiuddin Ahmed; Kareti Mahendranadh Reddy; Y Mahadev Shastry; S Venkat Aditya; P Jayakrishna Babu
Journal:  J Indian Prosthodont Soc       Date:  2020-07-17

10.  Effect of framework design on fracture resistance of zirconium oxide posterior fixed partial dentures.

Authors:  Hadi Salimi; Ramin Mosharraf; Omid Savabi
Journal:  Dent Res J (Isfahan)       Date:  2012-11