| Literature DB >> 33202809 |
Diego Jaén-Carrillo1, Luis E Roche-Seruendo1, Antonio Cartón-Llorente1, Rodrigo Ramírez-Campillo2, Felipe García-Pinillos3,4.
Abstract
Mechanical power may act as a key indicator for physiological and mechanical changes during running. In this scoping review, we examine the current evidences about the use of power output (PW) during endurance running and the different commercially available wearable sensors to assess PW. The Boolean phrases endurance OR submaximal NOT sprint AND running OR runner AND power OR power meter, were searched in PubMed, MEDLINE, and SCOPUS. Nineteen studies were finally selected for analysis. The current evidence about critical power and both power-time and power-duration relationships in running allow to provide coaches and practitioners a new promising setting for PW quantification with the use of wearable sensors. Some studies have assessed the validity and reliability of different available wearables for both kinematics parameters and PW when running but running power meters need further research before a definitive conclusion regarding its validity and reliability.Entities:
Keywords: biomechanics; endurance runners; long-distance athletes; wearable device
Mesh:
Year: 2020 PMID: 33202809 PMCID: PMC7696724 DOI: 10.3390/s20226482
Source DB: PubMed Journal: Sensors (Basel) ISSN: 1424-8220 Impact factor: 3.576
Figure 1Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) flow diagram.
Studies (n = 12) involving the use of wearable sensors with the capacity of measuring power during running protocols.
| References | Subject Description | Aim | System Used | Protocol | Outcome Measures | Results |
|---|---|---|---|---|---|---|
| Dobrijevic et al. (2017) [ | 30 physical education students (15 men and 15 women) | To explore the properties of the F-V relationship of leg muscles exerting the maximum pulling F at a wide range of V on a standard motorized treadmill | Motorized treadmill using externally fixed strain gauge dynamometer (CZL301, ALL4GYM, Serbia) connected to the subject wearing a wide and hard weightlifting belt | Walking and running on a treadmill at different velocities (1.4−3.3 m.s−1), and maximum pulling F exerted horizontally were recorded | Leg muscle capacities for producing maximum F, V, and power | The F-V relationship of leg muscles tested through a wide range of treadmill V could be strong, linear, and reliable. Moreover, the two-velocity method could provide reliable and ecologically valid indices of F, V, and P producing capacities of leg muscles. |
| García-Pinillos et al. (2019) [ | 49 endurance runners | To examine how the PW changes while running at a continuous comfortable velocity on a motorized treadmill by comparing running power averaged during different time intervals | Stryd system (foot pod) | Runners performed a 3 min running protocol at comfortable velocity and P was examined over six recording intervals within the 3-min recording period: 0−10 s, 0−20 s, 0−30 s, 0−60 s, 0−120 s and 0−180 s | Running PW | P during running is a stable metric with negligible differences, in practical terms, between shorter (i.e., 10, 20, 30, 60 or 120 s) and longer recording intervals (i.e., 180 s) |
| Aubry et al. (2018) [ | 24 male runners (13 recreational, 11 elite) | To investigate the applicability of running power (and its individually calculated run mechanics) to be a useful surrogate of metabolic demand (Vo2), across different running surfaces, within different caliber runners. | - Stryd system (chest strap) | 2 different test at 3 different paces, while wearing a Stryd on both an indoor and an outdoor test: | - Spatiotemporal parameters | Running power (with Stryd) is not a great reflection of the metabolic demand of running in a mixed ability population of runners |
| Snyder et al. (2017) [ | Manuscript clarification: Request for clarification to Aubry et al. (2018) | Some major methodological flaws in the mentioned paper are detected. The authors concluded that data analysis and, thereby, data interpretation are misleading | ||||
| Austin et al. (2018) [ | 17 well-trained distance runners | To measure the correlations between running economy and P and form power at LT pace. | - Stryd system (foot pod) | Participants ran two 4 min trials: one with a self-selected cadence, and one with a target cadence lowered by 10% | - Gas exchange measures | RE is positively correlated with Stryd’s power and form power measures yet the footpod may not be sufficiently accurate to estimate differences in the running economy of runners |
| García-Pinillos et al. (2019) [ | 18 recreationally-trained male endurance runners | To determine if the P-V relationship in endurance runners fits a linear model when running at submaximal velocities, as well as to examine the feasibility of the “two-point method” for estimating P at different velocities | Stryd system (foot pod) | Incremental running protocol on a treadmill. Initial speed was set at 8 km.h−1, and speed increased by 1 km.h−1 every 3 min until exhaustion | PW (W) | The two-point method based on distant velocities was able to provide P with the same accuracy than the multiple-point method. |
| Vandewalle et al. (2018) [ | Data from 6 elite endurance runners | - To apply the P-law and logarithmic models and four asymptotic models to the individual performances of the elite runners. | - | The empirical models were compared from the performance of 6 elite endurance runners who participated in international competitions over a large range of distances | Mathematical models to predict running performance | The predictions of long-distance performances (maximal running speeds for 30, 60 min and marathon) by extrapolation of the logarithmic and power-law models were more accurate than the predictions by extrapolation in all the asymptotic models. |
| Mulligan et al. (2018) [ | Data from various records for a range of distances | To develop a novel, minimal and universal model for human running performance that employs a relative metabolic P scale | - | European and world records performances for eight distances, from 1 km to the marathon, were analyzed | Mathematical models to predict running performance | The model presented provides a quantitative method for extracting characteristic parameters from race performances of runners. This is the to date most accurate theoretical description of running performances that does not require any a priori fixing of physiological constants |
| Gregory et al. (2019) [ | 12 young adults with history of ankle sprain | RunScribe system (foot pod, on the heel) | To evaluate the effects of ankle taping, bracing, and fibular reposition taping (FRT) on running biomechanics | Four 400 m runs at self-selected pace on an outdoor track. Each run was performed in a different condition (control, taped, braced, FRT) | - Spatiotemporal (CT, CycleT, SL) | Ankle taping and bracing were shown to be comparable in decreasing ankle kinematics and kinetics, while FRT caused minimal changes in running biomechanics |
| Leuchanka et al. (2019a) [ | 15 endurance runners | To examine the changes in spatiotemporal variables during a marathon race | RunScribe system (foot pod, on the lace shoe) | Monitoring spatiotemporal variables over a marathon race by comparing 3 points (km 5, 26 and 37) | - Spatiotemporal (Pace, CT, SL and cadence) | Significant differences were found in pace, SL, and CT when compared across 3 race points |
| Leuchanka et al. (2019b) [ | 15 endurance runners | To measure the kinematic asymmetry during a marathon race | RunScribe system (foot pod, on the lace shoe) | Monitoring kinematic variables over a marathon race by comparing 3 points (km 5, 26 and 37) | - Kinematic variables for right and left foot (pace, strike index, PR, PRveloc) | Changes in asymmetry were not found to be statistically significant over the marathon. |
| Cerezuela-Espejo et al. (2020) [ | 10 endurance runners | To analyse agreement level between power estimated PW by five commercial wearable systems and two theoretical models in different environments and conditions | 5 systems: | Three submaximal | Running PW derived from the 5 systems and theoretical PW from two mathematical models (TPw1 and TPw2). | The closest agreement of the Stryd and PolarV technologies with the TPW1 and TPW2 models suggest these tools as the most sensitive, among those analysed, for PW measurement when changing environments and running conditions |
CP: critical power; LT: blood lactate thresholds; Vo2max: maximal oxygen uptake; tlim: exhausting time at a given intensity; W´: residual performance capacity; F: force; V: velocity; P: power; Dlim: exhaustion distance; MTT: Montreal Track Test; MAS: maximal aerobic speed; CT: ground contact time; SL: step length; PR: pronation excursion; PRveloc: pronation velocity; TPw1: Mathematical model for power output (PW) estimation 1; TPw2: Mathematical model for PW estimation 2; PW: power output.
Studies (n = 7) examining the reliability and validity of different wearable sensors with the capacity to measure power during running.
| References | Subject Description | Tested System | Reference System | Protocol | Outcome Measures | Results |
|---|---|---|---|---|---|---|
| García-Pinillos et al. (2018) [ | 18 trained endurance runners | Stryd system (foot pod) | OptoGait system | Incremental running test (8−20 km·h−1 with 3-min stages) on a treadmill | - Spatiotemporal parameters (CT, FT, SL, SF) | Stryd is reliable for measuring spatiotemporal parameters. It provides accurate SL and SF measures but underestimates CT (0.5−8%) and overestimates FT (3−67%) |
| Koldenhoven et al. (2018) [ | 12 recreational runners | RunScribe wearable sensor | 3D motion capture system (Vicon system) | 2.4 km running protocol on treadmill, at self-selected speed | - PR, PRveloc, and CycleT | RunScribe showed good to excellent concurrent validity for the outcome measures |
| Brayne et al. (2018) [ | 13 runners | Wireless accelerometer (RunScribe): skin mounted | Uniaxial piezoresistive accelerometer (model 352C22, PCB Piezotronics): skin mounted | Participants ran at 3 different speeds on a treadmill (2.5, 3.5, 4.5 m.s−1) for a total of 40 s (10 s to regulate running gait and 30 s data collection) | - Peak tibial acceleration (g) | RunScribe accelerometer accurately measures peak tibial accelerations when compared to a research accelerometer, at a range of speeds |
| Hollis et al. (2019) [ | 15 recreational runners | RunScribe system (foot pod, on the heel) | Intra-system comparison (in different experimental conditions) | Two 1600 m runs (slow: 3−4; fast: 5−6 on a 0−10 RPE scale) on two surfaces (track, grass). Randomized order. | - Spatiotemporal (CT, CycleT, SL) | RunScribe sensor is valid to identify changes in the outcome |
| Navalta et al. (2019) [ | 20 young, healthy individuals | Stryd system (foot pod) | Intra-system reliability | Two 5 min self-paced walks along a trail, and two 5 min trail runs (5 min rest period) | - Pace and distance | Trail running task returns moderate to excellent reliability across all measures |
| García-Pinillos et al. (2019) [ | 49 amateur endurance runners | RunScribe system (foot pod) on 2 locations: | High-speed video analysis at 1000 Hz | Treadmill running for 3 min at self-selected comfortable velocity | - Spatiotemporal gait parameters (CT, FT, SL, SF) | RunScribe is a valid system to measure spatiotemporal parameters during running on a treadmill. The location of the RunScribe plays an important role on the accuracy of spatiotemporal parameters. The lace shoe placement showed smaller errors for CT, FT and SL, whereas the heel shoe was more accurate for SF |
| Cerezuela-Espejo et al. (2020) [ | 12 endurance-trained male athletes | 5 systems: | - Metabolic cart (VO2) | Participants were initially familiarized with the protocol and then, two protocols were performed in two different settings (outdoor vs. indoor): | - P output during running | The Stryd system is the most repeatable technology, among the five analyzed, for P estimation. |
CT: ground contact time; CycleT: cycle time; SL: step length; PR: pronation excursion; PRveloc: pronation velocity; RPE: rate of perceived exertion; FT: flight time; SF: step frequency; VO2: oxygen uptake; RE: running economy; PW: power output.
Modified Downs and Black scale [23].
| Study | Item 1 | Item 2 | Item 3 | Item 6 | Item 7 | Item 10 | Item 12 | Item 15 | Item 16 | Item 18 | Item 20 | Item 22 | Item 23 | Item 25 | Total (out of 14) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Dobrijevic et al. (2017) [ | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 0 | 1 | 13 |
| Aubry et al. (2018) [ | 1 | 1 | 1 | 1 | 1 | 1 | 0 | 1 | 1 | 1 | 1 | 1 | 0 | 1 | 12 |
| Austin et al. (2018) [ | 1 | 1 | 1 | 1 | 1 | 1 | 0 | 1 | 1 | 1 | 1 | 1 | 0 | 1 | 12 |
| García-Pinillos et al. (2019) [ | 1 | 1 | 1 | 1 | 1 | 1 | 0 | 1 | 1 | 1 | 1 | 1 | 0 | 1 | 12 |
| García-Pinillos et al. (2019) [ | 1 | 1 | 1 | 1 | 1 | 1 | 0 | 1 | 1 | 1 | 1 | 1 | 0 | 1 | 12 |
| Vandewalle et al. (2018) [ | 1 | 1 | 1 | 1 | 1 | 1 | 0 | U | 1 | 1 | 1 | 0 | 0 | 1 | 11 |
| Mulligan et al. (2018) [ | 1 | 1 | 1 | 1 | 1 | 1 | 0 | U | 1 | 1 | 1 | 0 | 0 | 1 | 11 |
| Gregory et al. (2019) [ | 1 | 1 | 1 | 1 | 1 | 1 | 0 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 13 |
| Leuchanka et al. (2019a) [ | 1 | 1 | 1 | 1 | 1 | 1 | 0 | 1 | 1 | 1 | 1 | 1 | 0 | 0 | 11 |
| Leuchanka et al. (2019b) [ | 1 | 1 | 1 | 1 | 1 | 1 | 0 | 1 | 1 | 1 | 1 | 1 | 0 | 0 | 11 |
| García-Pinillos et al. (2018) [ | 1 | 1 | 1 | 1 | 1 | 1 | 0 | 1 | 1 | 1 | 1 | 1 | 0 | 1 | 12 |
| Koldenhoven et al. (2018) [ | 1 | 1 | 1 | 1 | 1 | 1 | 0 | 1 | 1 | 1 | 1 | 1 | 0 | 1 | 12 |
| Brayne et al. (2018) [ | 1 | 1 | 1 | 1 | 1 | 1 | 0 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 13 |
| Hollis et al. (2019) [ | 1 | 1 | 1 | 1 | 1 | 1 | 0 | 1 | 1 | 1 | 1 | 1 | 0 | 1 | 12 |
| Navalta et al. (2019) [ | 1 | 1 | 1 | 1 | 1 | 1 | 0 | 1 | 1 | 1 | 1 | 1 | 0 | 1 | 12 |
| García-Pinillos et al. (2019) [ | 1 | 1 | 1 | 1 | 1 | 1 | 0 | 1 | 1 | 1 | 1 | 1 | 0 | 1 | 12 |
| Cerezuela-Espejo et al. (2020) [ | 1 | 1 | 1 | 1 | 1 | 1 | 0 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 13 |
| Cerezuela-Espejo et al. (2020) [ | 1 | 1 | 1 | 1 | 1 | 1 | 0 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 13 |
Key: 0 = no; 1 = yes; U = unable to determine. Item 1: clear aim/hypothesis; Item 2: outcome measures clearly described; Item 3: patient characteristics clearly described; Item 6: main findings clearly described; Item 7: measures of random variability provided; Item 10: actual probability values reported; Item 12: participants prepared to participate representative of entire population; Item 15: Blinding of outcome measures; Item 16: analysis completed was planned; Item 18: appropriate statistics; Item 20: valid and reliable outcome measures; Item 22: participants recruited over same period; Item 23: Randomised; Item 25: adjustment made for confounding variables.