Literature DB >> 31295744

How Does Power During Running Change when Measured at Different Time Intervals?

Felipe García-Pinillos1, Víctor M Soto-Hermoso2, Pedro Á Latorre-Román3, Juan A Párraga-Montilla4, Luis E Roche-Seruendo5.   

Abstract

This study aimed to examine how the power output changes while running at a continuous comfortable velocity on a motorized treadmill by comparing running power averaged during different time intervals. Forty-nine endurance runners performed a running protocol on a treadmill at self-selected comfortable velocity. Power output (W) was estimated with the Stryd™ power meter, and it was examined over six recording intervals within the 3-min recording period: 0-10 s, 0-20 s, 0-30 s, 0-60 s, 0-120 s and 0-180 s. The ANOVAs showed no significant differences in the magnitude of the power output between the recording intervals (p=0.276, F=1.614, partial Eta 2 =0.155). An almost perfect association was also observed in the magnitude of the power output between the recording intervals (ICC≥0.999). Bland-Altman plots revealed no heteroscedasticity of error for the power output in any of the between-intervals comparisons (r 2<0.1), although longer recording intervals yield smaller systematic bias, random errors, and narrower limits of agreement for power output. The results show that power data during running, as measured through the Stryd™ system, is a stable metric with negligible differences, in practical terms, between shorter (i. e., 10, 20, 30, 60 or 120 s) and longer recording intervals (i. e., 180 s). © Georg Thieme Verlag KG Stuttgart · New York.

Mesh:

Year:  2019        PMID: 31295744     DOI: 10.1055/a-0946-2159

Source DB:  PubMed          Journal:  Int J Sports Med        ISSN: 0172-4622            Impact factor:   3.118


  2 in total

1.  Influence of the Shod Condition on Running Power Output: An Analysis in Recreationally Active Endurance Runners.

Authors:  Diego Jaén-Carrillo; Luis E Roche-Seruendo; Alejandro Molina-Molina; Silvia Cardiel-Sánchez; Antonio Cartón-Llorente; Felipe García-Pinillos
Journal:  Sensors (Basel)       Date:  2022-06-26       Impact factor: 3.847

Review 2.  Mechanical Power in Endurance Running: A Scoping Review on Sensors for Power Output Estimation during Running.

Authors:  Diego Jaén-Carrillo; Luis E Roche-Seruendo; Antonio Cartón-Llorente; Rodrigo Ramírez-Campillo; Felipe García-Pinillos
Journal:  Sensors (Basel)       Date:  2020-11-13       Impact factor: 3.576

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.