Literature DB >> 32095758

Validation of a Wearable Sensor for Measuring Running Biomechanics.

Rachel M Koldenhoven1, Jay Hertel1.   

Abstract

BACKGROUND: Running biomechanics have traditionally been analyzed in laboratory settings, but this may not reflect natural running gait. Wearable sensors may offer an alternative.
METHODS: A concurrent validation study to determine agreement between the RunScribe<sup>TM</sup> wearable sensor (triaxial accelerometer and gyroscope) and the 3D motion capture system was conducted. Twelve injury-free participants (6 males, 6 females; age = 23.1 ± 5.5 years, weekly mileage = 16.1 ± 9.3) ran 1.5 miles on a treadmill. Ten consecutive strides from each limb were collected, and the mean values were analyzed. Pronation excursion, maximum pronation velocity, contact time, and cycle time were compared between measurement platforms using intraclass correlation coefficients (ICC) and Bland-Altman analyses.
RESULTS: Excellent ICC estimates were found for maximum pronation velocity, contact time, and cycle time. Pronation excursion demonstrated fair ICC estimates. The mean differences between platforms were small with limits of agreement clustered around zero, except for contact time measures which were consistently higher with the RunScribe compared to the camera-based system.
CONCLUSION: Our study revealed that the RunScribe wearable device showed good to excellent concurrent validity for maximum pronation velocity, contact time, and cycle time; however, direct comparisons or results between the two platforms should not be used.
Copyright © 2018 by S. Karger AG, Basel.

Entities:  

Keywords:  Bi-axial or tri-axial accelerometer devices; Gait; Monitor movement; Wearable physical activity monitoring; Wearables

Year:  2018        PMID: 32095758      PMCID: PMC7015375          DOI: 10.1159/000491645

Source DB:  PubMed          Journal:  Digit Biomark        ISSN: 2504-110X


  10 in total

1.  Etiologic factors associated with patellofemoral pain in runners.

Authors:  S P Messier; S E Davis; W W Curl; R B Lowery; R J Pack
Journal:  Med Sci Sports Exerc       Date:  1991-09       Impact factor: 5.411

2.  Comparison between an accelerometer and a three-dimensional motion analysis system for the detection of movement.

Authors:  P Y M Chung; G Y F Ng
Journal:  Physiotherapy       Date:  2011-10-02       Impact factor: 3.358

3.  A wearable smartphone-enabled camera-based system for gait assessment.

Authors:  Albert Kim; Junyoung Kim; Shirley Rietdyk; Babak Ziaie
Journal:  Gait Posture       Date:  2015-05-13       Impact factor: 2.840

Review 4.  Redefining the roles of sensors in objective physical activity monitoring.

Authors:  Kong Y Chen; Kathleen F Janz; Weimo Zhu; Robert J Brychta
Journal:  Med Sci Sports Exerc       Date:  2012-01       Impact factor: 5.411

5.  Gait retraining to reduce lower extremity loading in runners.

Authors:  Harrison Philip Crowell; Irene S Davis
Journal:  Clin Biomech (Bristol, Avon)       Date:  2011-01       Impact factor: 2.063

6.  Fitbit®: An accurate and reliable device for wireless physical activity tracking.

Authors:  Keith M Diaz; David J Krupka; Melinda J Chang; James Peacock; Yao Ma; Jeff Goldsmith; Joseph E Schwartz; Karina W Davidson
Journal:  Int J Cardiol       Date:  2015-03-04       Impact factor: 4.164

Review 7.  Gait Retraining: Altering the Fingerprint of Gait.

Authors:  Irene S Davis; Erin Futrell
Journal:  Phys Med Rehabil Clin N Am       Date:  2016-02       Impact factor: 1.784

Review 8.  Overuse injuries of the lower extremity in runners.

Authors:  C Rolf
Journal:  Scand J Med Sci Sports       Date:  1995-08       Impact factor: 4.221

9.  Concurrent validity of accelerometry to measure gait in Parkinsons Disease.

Authors:  Sue Lord; Lynn Rochester; Katherine Baker; Alice Nieuwboer
Journal:  Gait Posture       Date:  2007-06-28       Impact factor: 2.840

10.  Suspected mechanisms in the cause of overuse running injuries: a clinical review.

Authors:  Reed Ferber; Alan Hreljac; Karen D Kendall
Journal:  Sports Health       Date:  2009-05       Impact factor: 3.843

  10 in total
  5 in total

1.  Wearables for Running Gait Analysis: A Systematic Review.

Authors:  Rachel Mason; Liam T Pearson; Gillian Barry; Fraser Young; Oisin Lennon; Alan Godfrey; Samuel Stuart
Journal:  Sports Med       Date:  2022-10-15       Impact factor: 11.928

2.  Validity and Reliability of Inertial Measurement Units on Lower Extremity Kinematics During Running: A Systematic Review and Meta-Analysis.

Authors:  Ziwei Zeng; Yue Liu; Xiaoyue Hu; Meihua Tang; Lin Wang
Journal:  Sports Med Open       Date:  2022-06-27

3.  Validation of the RunScribe inertial measurement unit for walking gait measurement.

Authors:  Max Lewin; Carina Price; Christopher Nester
Journal:  PLoS One       Date:  2022-08-22       Impact factor: 3.752

Review 4.  Mechanical Power in Endurance Running: A Scoping Review on Sensors for Power Output Estimation during Running.

Authors:  Diego Jaén-Carrillo; Luis E Roche-Seruendo; Antonio Cartón-Llorente; Rodrigo Ramírez-Campillo; Felipe García-Pinillos
Journal:  Sensors (Basel)       Date:  2020-11-13       Impact factor: 3.576

Review 5.  Is This the Real Life, or Is This Just Laboratory? A Scoping Review of IMU-Based Running Gait Analysis.

Authors:  Lauren C Benson; Anu M Räisänen; Christian A Clermont; Reed Ferber
Journal:  Sensors (Basel)       Date:  2022-02-23       Impact factor: 3.576

  5 in total