Cone beam CT multisource configurations: evaluating image quality, scatter, and dose using phantom imaging and Monte Carlo simulations.

Amy E Becker1, Andrew M Hernandez2, Paul R Schwoebel3,4, John M Boone1,2.   

Abstract

The purpose of this study was to compare various multisource configurations applied to cone beam CT (CBCT) using phantom imaging and Monte Carlo simulations. Image quality, scatter, and dose were evaluated in both overlapping (large cone angle) and collimated (small cone angle) configurations for CBCT. Four x-ray tube configurations were considered: traditional one source, three source overlapping, six source overlapping, and six source collimated. Image quality was evaluated on a prototype breast CT system using the following five phantoms: a Defrise phantom, a previously reported CBCT QA phantom (Corgi), a polyethylene cylinder, and two anthropomorphic phantoms (hand and knee). Scatter contamination and radiation dose were evaluated using Monte Carlo simulations of a voxelized polyethylene cylinder. The modulation of the Defrise phantom disks on average was 2.7X greater for the six source collimated configuration than the six source overlapping configuration. The data lost from cone beam artifact (spatial domain) and the null cone (frequency domain) in the overlapping configuration were completely recovered using the collimated configuration. The maximum scatter-to-primary ratio (SPR) for the overlapping configuration was 0.81 and the maximum SPR for the collimated configuration was 0.26. The average dose and maximum dose was 4X less in the collimated six source configuration when compared with the overlapping configurations. The maximum dose for the overlapping configurations (one, three & six) remained constant, but the average dose for the multisource (three & six source) overlapping configurations increased 25% when compared to the one source configuration. Use of a collimated multisource x-ray tube configuration was shown to provide significant improvements in image quality throughout the cone-beam geometry field-of-view, reduction in scatter contamination, and more efficient use of dose in comparison to both the traditional CBCT geometry with a single source and the overlapping multisource configurations.

Entities:  

Mesh:

Year:  2020        PMID: 33080583      PMCID: PMC8561950          DOI: 10.1088/1361-6560/abc306

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  39 in total

1.  The influence of antiscatter grids on soft-tissue detectability in cone-beam computed tomography with flat-panel detectors.

Authors:  J H Siewerdsen; D J Moseley; B Bakhtiar; S Richard; D A Jaffray
Journal:  Med Phys       Date:  2004-12       Impact factor: 4.071

2.  An efficient Monte Carlo-based algorithm for scatter correction in keV cone-beam CT.

Authors:  G Poludniowski; P M Evans; V N Hansen; S Webb
Journal:  Phys Med Biol       Date:  2009-06-02       Impact factor: 3.609

3.  A local shift-variant Fourier model and experimental validation of circular cone-beam computed tomography artifacts.

Authors:  Steven Bartolac; Roll Clackdoyle; Frederic Noo; Jeff Siewerdsen; Douglas Moseley; David Jaffray
Journal:  Med Phys       Date:  2009-02       Impact factor: 4.071

4.  Bone quality evaluation at dental implant site using multislice CT, micro-CT, and cone beam CT.

Authors:  Azin Parsa; Norliza Ibrahim; Bassam Hassan; Paul van der Stelt; Daniel Wismeijer
Journal:  Clin Oral Implants Res       Date:  2013-12-11       Impact factor: 5.977

5.  Location dependency of the spatial resolution of cone beam computed tomography for dental use.

Authors:  Yoshihiro Ozaki; Hiroshi Watanabe; Yoshikazu Nomura; Eiichi Honda; Yasunori Sumi; Tohru Kurabayashi
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol       Date:  2013-11

6.  A stationary computed tomography system with cylindrically distributed sources and detectors.

Authors:  Yi Chen; Yan Xi; Jun Zhao
Journal:  J Xray Sci Technol       Date:  2014       Impact factor: 1.535

7.  Multithreaded cardiac CT.

Authors:  Marc Kachelriess; Michael Knaup; Willi A Kalender
Journal:  Med Phys       Date:  2006-07       Impact factor: 4.071

8.  Tungsten anode spectral model using interpolating cubic splines: unfiltered x-ray spectra from 20 kV to 640 kV.

Authors:  Andrew M Hernandez; John M Boone
Journal:  Med Phys       Date:  2014-04       Impact factor: 4.071

9.  Optimization-based scatter estimation using primary modulation for computed tomography.

Authors:  Yi Chen; Ying Song; Jingchen Ma; Jun Zhao
Journal:  Med Phys       Date:  2016-08       Impact factor: 4.071

10.  3D analytic cone-beam reconstruction for multiaxial CT acquisitions.

Authors:  Zhye Yin; Bruno De Man; Jed Pack
Journal:  Int J Biomed Imaging       Date:  2009-08-30
View more
  1 in total

1.  A prototype Multi-X-ray-source array (MXA) for digital breast tomosynthesis.

Authors:  Amy E Becker; Andrew M Hernandez; John M Boone; Paul R Schwoebel
Journal:  Phys Med Biol       Date:  2020-12-18       Impact factor: 3.609

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.