Literature DB >> 19491449

An efficient Monte Carlo-based algorithm for scatter correction in keV cone-beam CT.

G Poludniowski1, P M Evans, V N Hansen, S Webb.   

Abstract

A new method is proposed for scatter-correction of cone-beam CT images. A coarse reconstruction is used in initial iteration steps. Modelling of the x-ray tube spectra and detector response are included in the algorithm. Photon diffusion inside the imaging subject is calculated using the Monte Carlo method. Photon scoring at the detector is calculated using forced detection to a fixed set of node points. The scatter profiles are then obtained by linear interpolation. The algorithm is referred to as the coarse reconstruction and fixed detection (CRFD) technique. Scatter predictions are quantitatively validated against a widely used general-purpose Monte Carlo code: BEAMnrc/EGSnrc (NRCC, Canada). Agreement is excellent. The CRFD algorithm was applied to projection data acquired with a Synergy XVI CBCT unit (Elekta Limited, Crawley, UK), using RANDO and Catphan phantoms (The Phantom Laboratory, Salem NY, USA). The algorithm was shown to be effective in removing scatter-induced artefacts from CBCT images, and took as little as 2 min on a desktop PC. Image uniformity was greatly improved as was CT-number accuracy in reconstructions. This latter improvement was less marked where the expected CT-number of a material was very different to the background material in which it was embedded.

Mesh:

Year:  2009        PMID: 19491449     DOI: 10.1088/0031-9155/54/12/016

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  25 in total

1.  Characterization and correction of cupping effect artefacts in cone beam CT.

Authors:  A K Hunter; W D McDavid
Journal:  Dentomaxillofac Radiol       Date:  2012-03       Impact factor: 2.419

2.  A GPU tool for efficient, accurate, and realistic simulation of cone beam CT projections.

Authors:  Xun Jia; Hao Yan; Laura Cervino; Michael Folkerts; Steve B Jiang
Journal:  Med Phys       Date:  2012-12       Impact factor: 4.071

3.  Monte Carlo study of the effects of system geometry and antiscatter grids on cone-beam CT scatter distributions.

Authors:  A Sisniega; W Zbijewski; A Badal; I S Kyprianou; J W Stayman; J J Vaquero; J H Siewerdsen
Journal:  Med Phys       Date:  2013-05       Impact factor: 4.071

4.  A model-based scatter artifacts correction for cone beam CT.

Authors:  Wei Zhao; Don Vernekohl; Jun Zhu; Luyao Wang; Lei Xing
Journal:  Med Phys       Date:  2016-04       Impact factor: 4.071

5.  Learning-based CBCT correction using alternating random forest based on auto-context model.

Authors:  Yang Lei; Xiangyang Tang; Kristin Higgins; Jolinta Lin; Jiwoong Jeong; Tian Liu; Anees Dhabaan; Tonghe Wang; Xue Dong; Robert Press; Walter J Curran; Xiaofeng Yang
Journal:  Med Phys       Date:  2018-12-11       Impact factor: 4.071

6.  A practical cone-beam CT scatter correction method with optimized Monte Carlo simulations for image-guided radiation therapy.

Authors:  Yuan Xu; Ti Bai; Hao Yan; Luo Ouyang; Arnold Pompos; Jing Wang; Linghong Zhou; Steve B Jiang; Xun Jia
Journal:  Phys Med Biol       Date:  2015-04-10       Impact factor: 3.609

7.  Acuros CTS: A fast, linear Boltzmann transport equation solver for computed tomography scatter - Part I: Core algorithms and validation.

Authors:  Alexander Maslowski; Adam Wang; Mingshan Sun; Todd Wareing; Ian Davis; Josh Star-Lack
Journal:  Med Phys       Date:  2018-04-06       Impact factor: 4.071

8.  Transmission characteristics of a two dimensional antiscatter grid prototype for CBCT.

Authors:  Cem Altunbas; Brian Kavanagh; Timur Alexeev; Moyed Miften
Journal:  Med Phys       Date:  2017-06-16       Impact factor: 4.071

9.  CT to cone-beam CT deformable registration with simultaneous intensity correction.

Authors:  Xin Zhen; Xuejun Gu; Hao Yan; Linghong Zhou; Xun Jia; Steve B Jiang
Journal:  Phys Med Biol       Date:  2012-10-03       Impact factor: 3.609

10.  Compressed sensing inspired image reconstruction from overlapped projections.

Authors:  Lin Yang; Yang Lu; Ge Wang
Journal:  Int J Biomed Imaging       Date:  2010-06-22
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.