Literature DB >> 32870789

Fast Acoustic Steering Via Tilting Electromechanical Reflectors (FASTER): A Novel Method for High Volume Rate 3-D Ultrasound Imaging.

Zhijie Dong, Shuangliang Li, Matthew R Lowerison, Jason Pan, Jun Zou, Pengfei Song.   

Abstract

The 3-D ultrasound imaging is essential for a wide range of clinical applications in diagnostic and interventional cardiology, radiology, and obstetrics for prenatal imaging. 3-D ultrasound imaging is also pivotal for advancing technical developments of emerging imaging technologies, such as elastography, blood flow imaging, functional ultrasound (fUS), and super-resolution microvessel imaging. At present, however, existing 3-D ultrasound imaging methods suffer from low imaging volume rate, suboptimal imaging quality, and high costs associated with 2-D ultrasound transducers. Here, we report a novel 3-D ultrasound imaging technique, fast acoustic steering via tilting electromechanical reflectors (FASTER), which provides both high imaging quality and fast imaging speed while at low cost. Capitalizing upon unique water immersible and fast-tilting microfabricated mirror to scan ultrafast plane waves in the elevational direction, FASTER is capable of high volume rate, large field-of-view (FOV) 3-D imaging with conventional 1-D transducers. In this article, we introduce the fundamental concepts of FASTER and present a series of calibration and validation studies for FASTER 3-D imaging. In a wire phantom and tissue-mimicking phantom study, we demonstrated that FASTER was capable of providing spatially accurate 3-D images with a 500-Hz imaging volume rate and an imaging FOV with a range of 48° (20 mm at 25-mm depth) in the elevational direction. We also showed that FASTER had comparable imaging quality with conventional mechanical translation-based 3-D imaging. The principles and results presented in this study establish the technical foundation for the new paradigm of high volume rate 3-D ultrasound imaging based on ultrafast plane waves and fast-tilting, water-immersible microfabricated mirrors.

Entities:  

Year:  2021        PMID: 32870789      PMCID: PMC7987349          DOI: 10.1109/TUFFC.2020.3020871

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  12 in total

1.  3D ultrasound measurement of large organ volume.

Authors:  G Treece; R Prager; A Gee; L Berman
Journal:  Med Image Anal       Date:  2001-03       Impact factor: 8.545

2.  Calibration of three-dimensional ultrasound images for image-guided radiation therapy.

Authors:  L G Bouchet; S L Meeks; G Goodchild; F J Bova; J M Buatti; W A Friedman
Journal:  Phys Med Biol       Date:  2001-02       Impact factor: 3.609

Review 3.  A review of calibration techniques for freehand 3-D ultrasound systems.

Authors:  Laurence Mercier; Thomas Langø; Frank Lindseth; D Louis Collins
Journal:  Ultrasound Med Biol       Date:  2005-04       Impact factor: 2.998

Review 4.  Freehand 3D ultrasound reconstruction algorithms--a review.

Authors:  Ole Vegard Solberg; Frank Lindseth; Hans Torp; Richard E Blake; Toril A Nagelhus Hernes
Journal:  Ultrasound Med Biol       Date:  2007-05-18       Impact factor: 2.998

5.  Sparse 2-D array design for real time rectilinear volumetric imaging.

Authors:  J T Yen; J P Steinberg; S W Smith
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2000       Impact factor: 2.725

6.  Coherent plane-wave compounding for very high frame rate ultrasonography and transient elastography.

Authors:  Gabriel Montaldo; Mickaël Tanter; Jérémy Bercoff; Nicolas Benech; Mathias Fink
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-03       Impact factor: 2.725

7.  3-D imaging using row-column-addressed arrays with integrated apodization - part i: apodization design and line element beamforming.

Authors:  Morten Fischer Rasmussen; Thomas Lehrmann Christiansen; Erik Vilain Thomsen; Jørgen Arendt Jensen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2015-05       Impact factor: 2.725

8.  Three-dimensional ultrasound scanning.

Authors:  Aaron Fenster; Grace Parraga; Jeff Bax
Journal:  Interface Focus       Date:  2011-06-01       Impact factor: 3.906

9.  Second-generation optical-resolution photoacoustic microscopy with improved sensitivity and speed.

Authors:  Song Hu; Konstantin Maslov; Lihong V Wang
Journal:  Opt Lett       Date:  2011-04-01       Impact factor: 3.776

10.  Detection of deep-vein thrombosis by real-time B-mode ultrasonography.

Authors:  A W Lensing; P Prandoni; D Brandjes; P M Huisman; M Vigo; G Tomasella; J Krekt; J Wouter Ten Cate; M V Huisman; H R Büller
Journal:  N Engl J Med       Date:  1989-02-09       Impact factor: 91.245

View more
  1 in total

1.  Actuated Reflector-Based 3-D Ultrasound Imaging With Synthetic Aperture Focusing.

Authors:  Yichuan Tang; Ryosuke Tsumura; Jakub Tomasz Kaminski; Haichong K Zhang
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2022-07-29       Impact factor: 3.267

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.