Literature DB >> 25974918

3-D imaging using row-column-addressed arrays with integrated apodization - part i: apodization design and line element beamforming.

Morten Fischer Rasmussen, Thomas Lehrmann Christiansen, Erik Vilain Thomsen, Jørgen Arendt Jensen.   

Abstract

This paper investigates the effect of transducerintegrated apodization in row-column-addressed arrays and presents a beamforming approach specific for such arrays. Row-column addressing 2-D arrays greatly reduces the number of active channels needed to acquire a 3-D volume. A disadvantage of row-column-addressed arrays is an apparent ghost effect in the point spread function caused by edge waves. This paper investigates the origin of the edge waves and the effect of introducing an integrated apodization to reduce the ghost echoes. The performance of a λ/2-pitch 5-MHz 128 + 128 row-column-addressed array with different apodizations is simulated. A Hann apodization is shown to decrease imaging performance away from the center axis of the array because of a decrease in main lobe amplitude. Instead, a static roll-off apodization region located at the ends of the line elements is proposed. In simulations, the peak ghost echo intensity of a scatterer at (x,y, z) = (8, 3, 30) mm was decreased by 43 dB by integrating roll-off apodization into the array. The main lobe was unaffected by the apodization. Simulations of a 3-mm-diameter anechoic blood vessel at 30 mm depth showed that applying the transducer-integrated apodization increased the apparent diameter of the vessel from 2.0 mm to 2.4 mm, corresponding to an increase from 67% to 80% of the true vessel diameter. The line element beamforming approach is shown to be essential for achieving correct time-of-flight calculations, and hence avoid geometrical distortions. In Part II of this work, experimental results from a capacitive micromachined ultrasonic transducer with integrated roll-off apodization are given to validate the effect of integrating apodization into the line elements.

Entities:  

Year:  2015        PMID: 25974918     DOI: 10.1109/TUFFC.2014.006531

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  11 in total

1.  A theranostic 3D ultrasound imaging system for high resolution image-guided therapy.

Authors:  Hanna Bendjador; Josquin Foiret; Robert Wodnicki; Douglas N Stephens; Zoe Krut; Eun-Yeong Park; Zulma Gazit; Dan Gazit; Gadi Pelled; Katherine W Ferrara
Journal:  Theranostics       Date:  2022-06-27       Impact factor: 11.600

2.  Design of a Volumetric Imaging Sequence Using a Vantage-256 Ultrasound Research Platform Multiplexed With a 1024-Element Fully Sampled Matrix Array.

Authors:  Jaesok Yu; Heechul Yoon; Yousuf M Khalifa; Stanislav Y Emelianov
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-09-19       Impact factor: 2.725

3.  Ultrasound Open Platforms for Next-Generation Imaging Technique Development.

Authors:  Enrico Boni; Alfred C H Yu; Steven Freear; Jorgen Arendt Jensen; Piero Tortoli
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-07       Impact factor: 2.725

4.  A Row-Column (RC) Addressed 2-D Capacitive Micromachined Ultrasonic Transducer (CMUT) Array on a Glass Substrate.

Authors:  Jean L Sanders; Ali Onder Biliroglu; Xun Wu; Oluwafemi J Adelegan; Feysel Yalcin Yamaner; Omer Oralkan
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2021-02-25       Impact factor: 2.725

5.  A Wearable Ultrasonic Neurostimulator - Part I: A 1D CMUT Phased Array System for Chronic Implantation in Small Animals.

Authors:  Chunkyun Seok; Feysel Yalcin Yamaner; Mesut Sahin; Omer Oralkan
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2021-09-15       Impact factor: 5.234

6.  Compensated Row-Column Ultrasound Imaging System Using Multilayered Edge Guided Stochastically Fully Connected Random Fields.

Authors:  Ibrahim Ben Daya; Albert I H Chen; Mohammad Javad Shafiee; Alexander Wong; John T W Yeow
Journal:  Sci Rep       Date:  2017-09-06       Impact factor: 4.379

Review 7.  Current Development and Applications of Super-Resolution Ultrasound Imaging.

Authors:  Qiyang Chen; Hyeju Song; Jaesok Yu; Kang Kim
Journal:  Sensors (Basel)       Date:  2021-04-01       Impact factor: 3.576

8.  Compensated Row-Column Ultrasound Imaging System Using Fisher Tippett Multilayered Conditional Random Field Model.

Authors:  Ibrahim Ben Daya; Albert I H Chen; Mohammad Javad Shafiee; Alexander Wong; John T W Yeow
Journal:  PLoS One       Date:  2015-12-11       Impact factor: 3.240

9.  The Design and Analysis of Split Row-Column Addressing Array for 2-D Transducer.

Authors:  Xu Li; Yanping Jia; Mingyue Ding; Ming Yuchi
Journal:  Sensors (Basel)       Date:  2016-09-27       Impact factor: 3.576

10.  Intraoperative Functional Ultrasound Imaging of Human Brain Activity.

Authors:  Marion Imbault; Dorian Chauvet; Jean-Luc Gennisson; Laurent Capelle; Mickael Tanter
Journal:  Sci Rep       Date:  2017-08-04       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.