Calibration of three-dimensional ultrasound images for image-guided radiation therapy.

L G Bouchet1, S L Meeks, G Goodchild, F J Bova, J M Buatti, W A Friedman.   

Abstract

A new technique of patient positioning for radiotherapy/radiosurgery of extracranial tumours using three-dimensional (3D) ultrasound images has been developed. The ultrasound probe position is tracked within the treatment room via infrared light emitting diodes (IRLEDs) attached to the probe. In order to retrieve the corresponding room position of the ultrasound image, we developed an initial ultrasound probe calibration technique for both 2D and 3D ultrasound systems. This technique is based on knowledge of points in both room and image coordinates. We first tested the performance of three algorithms in retrieving geometrical transformations using synthetic data with different noise levels. Closed form solution algorithms (singular value decomposition and Horn's quaternion algorithms) were shown to outperform the Hooke and Jeeves iterative algorithm in both speed and accuracy. Furthermore, these simulations show that for a random noise level of 2.5, 5, 7.5 and 10 mm, the number of points required for a transformation accuracy better than 1 mm is 25, 100, 200 and 500 points respectively. Finally, we verified the tracking accuracy of this system using a specially designed ultrasound phantom. Since ultrasound images have a high noise level, we designed an ultrasound phantom that provides a large number of points for the calibration. This tissue equivalent phantom is made of nylon wires, and its room position is optically tracked using IRLEDs. By obtaining multiple images through the nylon wires, the calibration technique uses an average of 300 points for 3D ultrasound volumes and 200 for 2D ultrasound images, and its stability is very good for both rotation (standard deviation: 0.4 degrees) and translation (standard deviation: 0.3 mm) transformations. After this initial calibration procedure, the position of any voxel in the ultrasound image volume can be determined in world space, thereby allowing real-time image guidance of therapeutic procedures. Finally, the overall tracking accuracy of our 3D ultrasound image-guided positioning system was measured to be on average 0.2 mm, 0.9 mm and 0.6 mm for the AP, lateral and axial directions respectively.

Entities:  

Mesh:

Year:  2001        PMID: 11229734     DOI: 10.1088/0031-9155/46/2/321

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  10 in total

1.  In vivo reproducibility of robotic probe placement for a novel ultrasound-guided radiation therapy system.

Authors:  Muyinatu A Lediju Bell; H Tutkun Sen; Iulian Iordachita; Peter Kazanzides; John Wong
Journal:  J Med Imaging (Bellingham)       Date:  2014-07-23

2.  Comparing calibration approaches for 3D ultrasound probes.

Authors:  C Bergmeir; M Seitel; C Frank; R De Simone; H-P Meinzer; I Wolf
Journal:  Int J Comput Assist Radiol Surg       Date:  2008-11-04       Impact factor: 2.924

3.  Commissioning of a novel microCT/RT system for small animal conformal radiotherapy.

Authors:  Manuel Rodriguez; Hu Zhou; Paul Keall; Edward Graves
Journal:  Phys Med Biol       Date:  2009-05-28       Impact factor: 3.609

4.  Medical physics practice in the next decade.

Authors:  Bhudatt Paliwal
Journal:  J Med Phys       Date:  2006-07

5.  Spatial calibration of a 2D/3D ultrasound using a tracked needle.

Authors:  Francisco Vasconcelos; Donald Peebles; Sebastien Ourselin; Danail Stoyanov
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-04-08       Impact factor: 2.924

6.  Actuator-Assisted Calibration of Freehand 3D Ultrasound System.

Authors:  Terry K Koo; Nathaniel Silvia
Journal:  J Healthc Eng       Date:  2018-05-02       Impact factor: 2.682

7.  A Novel Design of N-Fiducial Phantom for Automatic Ultrasound Calibration.

Authors:  Maria Chatrasingh; Jackrit Suthakorn
Journal:  J Med Phys       Date:  2019 Jul-Sep

8.  A phantom-based analysis for tracking intra-fraction pancreatic tumor motion by ultrasound imaging during radiation therapy.

Authors:  Tianlong Ji; Ziwei Feng; Edward Sun; Sook Kien Ng; Lin Su; Yin Zhang; Dong Han; Sarah Han-Oh; Iulian Iordachita; Junghoon Lee; Peter Kazanzides; Muyinatu A Lediju Bell; John Wong; Kai Ding
Journal:  Front Oncol       Date:  2022-09-27       Impact factor: 5.738

9.  Rapid fabrication of custom patient biopsy guides.

Authors:  Didier A Rajon; Frank J Bova; Yueh-Yun Chi; William A Friedman
Journal:  J Appl Clin Med Phys       Date:  2009-09-02       Impact factor: 2.102

10.  Fast Acoustic Steering Via Tilting Electromechanical Reflectors (FASTER): A Novel Method for High Volume Rate 3-D Ultrasound Imaging.

Authors:  Zhijie Dong; Shuangliang Li; Matthew R Lowerison; Jason Pan; Jun Zou; Pengfei Song
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2021-02-25       Impact factor: 2.725

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.