Literature DB >> 19411209

Coherent plane-wave compounding for very high frame rate ultrasonography and transient elastography.

Gabriel Montaldo1, Mickaël Tanter, Jérémy Bercoff, Nicolas Benech, Mathias Fink.   

Abstract

The emergence of ultrafast frame rates in ultrasonic imaging has been recently made possible by the development of new imaging modalities such as transient elastography. Data acquisition rates reaching more than thousands of images per second enable the real-time visualization of shear mechanical waves propagating in biological tissues, which convey information about local viscoelastic properties of tissues. The first proposed approach for reaching such ultrafast frame rates consists of transmitting plane waves into the medium. However, because the beamforming process is then restricted to the receive mode, the echographic images obtained in the ultrafast mode suffer from a low quality in terms of resolution and contrast and affect the robustness of the transient elastography mode. It is here proposed to improve the beamforming process by using a coherent recombination of compounded plane-wave transmissions to recover high-quality echographic images without degrading the high frame rate capabilities. A theoretical model is derived for the comparison between the proposed method and the conventional B-mode imaging in terms of contrast, signal-to-noise ratio, and resolution. Our model predicts that a significantly smaller number of insonifications, 10 times lower, is sufficient to reach an image quality comparable to conventional B-mode. Theoretical predictions are confirmed by in vitro experiments performed in tissue-mimicking phantoms. Such results raise the appeal of coherent compounds for use with standard imaging modes such as B-mode or color flow. Moreover, in the context of transient elastography, ultrafast frame rates can be preserved while increasing the image quality compared with flat insonifications. Improvements on the transient elastography mode are presented and discussed.

Mesh:

Year:  2009        PMID: 19411209     DOI: 10.1109/TUFFC.2009.1067

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  225 in total

1.  AN OVERVIEW OF ELASTOGRAPHY - AN EMERGING BRANCH OF MEDICAL IMAGING.

Authors:  Armen Sarvazyan; Timothy J Hall; Matthew W Urban; Mostafa Fatemi; Salavat R Aglyamov; Brian S Garra
Journal:  Curr Med Imaging Rev       Date:  2011-11

2.  Characterization of material properties of soft solid thin layers with acoustic radiation force and wave propagation.

Authors:  Matthew W Urban; Ivan Z Nenadic; Bo Qiang; Miguel Bernal; Shigao Chen; James F Greenleaf
Journal:  J Acoust Soc Am       Date:  2015-10       Impact factor: 1.840

3.  Improved Shear Wave Motion Detection Using Pulse-Inversion Harmonic Imaging With a Phased Array Transducer.

Authors:  Matthew W Urban; Armando Manduca; Sorin V Pislaru; Randall R Kinnick; Cristina Pislaru; James F Greenleaf
Journal:  IEEE Trans Med Imaging       Date:  2013-09-05       Impact factor: 10.048

4.  Real time SVD-based clutter filtering using randomized singular value decomposition and spatial downsampling for micro-vessel imaging on a Verasonics ultrasound system.

Authors:  U-Wai Lok; Pengfei Song; Joshua D Trzasko; Ron Daigle; Eric A Borisch; Chengwu Huang; Ping Gong; Shanshan Tang; Wenwu Ling; Shigao Chen
Journal:  Ultrasonics       Date:  2020-04-25       Impact factor: 2.890

5.  Quantitative Inflammation Assessment for Crohn Disease Using Ultrasensitive Ultrasound Microvessel Imaging: A Pilot Study.

Authors:  Ping Gong; Pengfei Song; Amy B Kolbe; Shannon P Sheedy; Chengwu Huang; Wenwu Ling; Yue Yu; Chenyun Zhou; U Wai Lok; Shanshan Tang; David H Bruining; John M Knudsen; Shigao Chen
Journal:  J Ultrasound Med       Date:  2020-04-16       Impact factor: 2.153

6.  Hadamard-Encoded Multipulses for Contrast-Enhanced Ultrasound Imaging.

Authors:  Ping Gong; Pengfei Song; Shigao Chen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2017-08-30       Impact factor: 2.725

7.  Optimization of Transmit Parameters in Cardiac Strain Imaging With Full and Partial Aperture Coherent Compounding.

Authors:  Vincent Sayseng; Julien Grondin; Elisa E Konofagou
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-05       Impact factor: 2.725

8.  Probe Oscillation Shear Wave Elastography: Initial In Vivo Results in Liver.

Authors:  Daniel C Mellema; Pengfei Song; Randall R Kinnick; Joshua D Trzasko; Matthew W Urban; James F Greenleaf; Armando Manduca; Shigao Chen
Journal:  IEEE Trans Med Imaging       Date:  2018-05       Impact factor: 10.048

9.  Nondestructive Detection of Targeted Microbubbles Using Dual-Mode Data and Deep Learning for Real-Time Ultrasound Molecular Imaging.

Authors:  Dongwoon Hyun; Lotfi Abou-Elkacem; Rakesh Bam; Leandra L Brickson; Carl D Herickhoff; Jeremy J Dahl
Journal:  IEEE Trans Med Imaging       Date:  2020-04-09       Impact factor: 10.048

10.  Nonlinear X-wave ultrasound imaging of acoustic biomolecules.

Authors:  David Maresca; Daniel P Sawyer; Guillaume Renaud; Audrey Lee-Gosselin; Mikhail G Shapiro
Journal:  Phys Rev X       Date:  2018-10-04       Impact factor: 15.762

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.