Abstract

The past two decades have witnessed developments of new imaging techniques that provide three-dimensional images about the interior of the human body in a manner never before available. Ultrasound (US) imaging is an important cost-effective technique used routinely in the management of a number of diseases. However, two-dimensional viewing of three-dimensional anatomy, using conventional two-dimensional US, limits our ability to quantify and visualize the anatomy and guide therapy, because multiple two-dimensional images must be integrated mentally. This practice is inefficient, and may lead to variability and incorrect diagnoses. Investigators and companies have addressed these limitations by developing three-dimensional US techniques. Thus, in this paper, we review the various techniques that are in current use in three-dimensional US imaging systems, with a particular emphasis placed on the geometric accuracy of the generation of three-dimensional images. The principles involved in three-dimensional US imaging are then illustrated with a diagnostic and an interventional application: (i) three-dimensional carotid US imaging for quantification and monitoring of carotid atherosclerosis and (ii) three-dimensional US-guided prostate biopsy.

Entities:  

Keywords:  computed tomography; radiographic imaging; three-dimensional ultrasound scanning

Year:  2011        PMID: 22866228      PMCID: PMC3262266          DOI: 10.1098/rsfs.2011.0019

Source DB:  PubMed          Journal:  Interface Focus        ISSN: 2042-8898            Impact factor:   3.906


  98 in total

1.  Optimum scan spacing for three-dimensional ultrasound by speckle statistics.

Authors:  W L Smith; A Fenster
Journal:  Ultrasound Med Biol       Date:  2000-05       Impact factor: 2.998

2.  Theoretical and experimental quantification of carotid plaque volume measurements made by three-dimensional ultrasound using test phantoms.

Authors:  Anthony Landry; Aaron Fenster
Journal:  Med Phys       Date:  2002-10       Impact factor: 4.071

3.  Probe calibration for freehand 3-D ultrasound.

Authors:  Frank Lindseth; Geir Arne Tangen; Thomas Langø; Jon Bang
Journal:  Ultrasound Med Biol       Date:  2003-11       Impact factor: 2.998

4.  Evaluation of in vitro measurement accuracy of a three-dimensional ultrasound scanner.

Authors:  D L King; D L King; M Y Shao
Journal:  J Ultrasound Med       Date:  1991-02       Impact factor: 2.153

5.  Three-dimensional ultrasound-guided robotic needle placement: an experimental evaluation.

Authors:  Emad M Boctor; Michael A Choti; Everette C Burdette; Robert J Webster Iii
Journal:  Int J Med Robot       Date:  2008-06       Impact factor: 2.547

6.  Three-dimensional sonographically monitored cryosurgery in a prostate phantom.

Authors:  G M Onik; D B Downey; A Fenster
Journal:  J Ultrasound Med       Date:  1996-03       Impact factor: 2.153

7.  Volume estimation from multiplanar 2D ultrasound images using a remote electromagnetic position and orientation sensor.

Authors:  S W Hughes; T J D'Arcy; D J Maxwell; W Chiu; A Milner; J E Saunders; R J Sheppard
Journal:  Ultrasound Med Biol       Date:  1996       Impact factor: 2.998

8.  Effects of prolonged intensive lipid-lowering therapy on the characteristics of carotid atherosclerotic plaques in vivo by MRI: a case-control study.

Authors:  X Q Zhao; C Yuan; T S Hatsukami; E H Frechette; X J Kang; K R Maravilla; B G Brown
Journal:  Arterioscler Thromb Vasc Biol       Date:  2001-10       Impact factor: 8.311

9.  Ultrasonic three-dimensional reconstruction: in vitro and in vivo volume and area measurement.

Authors:  T C Hodges; P R Detmer; D H Burns; K W Beach; D E Strandness
Journal:  Ultrasound Med Biol       Date:  1994       Impact factor: 2.998

10.  Ultrafast three-dimensional ultrasound: application to carotid artery imaging.

Authors:  C Palombo; M Kozakova; C Morizzo; F Andreuccetti; A Tondini; P Palchetti; G Mirra; G Parenti; N G Pandian
Journal:  Stroke       Date:  1998-08       Impact factor: 7.914

View more
  12 in total

Review 1.  Recent developments in vascular ultrasound technology.

Authors:  P R Hoskins; D A Kenwright
Journal:  Ultrasound       Date:  2015-03-26

Review 2.  Secondary Stroke Prevention: Improving Diagnosis and Management with Newer Technologies.

Authors:  Yahia Z Imam; Atlantic D'Souza; Rayaz A Malik; Ashfaq Shuaib
Journal:  Transl Stroke Res       Date:  2016-09-02       Impact factor: 6.829

Review 3.  What is new in computer vision and artificial intelligence in medical image analysis applications.

Authors:  Jimena Olveres; Germán González; Fabian Torres; José Carlos Moreno-Tagle; Erik Carbajal-Degante; Alejandro Valencia-Rodríguez; Nahum Méndez-Sánchez; Boris Escalante-Ramírez
Journal:  Quant Imaging Med Surg       Date:  2021-08

4.  Using game controller as position tracking sensor for 3D freehand ultrasound imaging.

Authors:  Vei Siang Chan; Farhan Mohamed; Yusman Azimi Yusoff; Dyah Ekashanti Octorina Dewi; Alfiera Anuar; Mohamad Amir Shamsudin; Wey Sheng Mong
Journal:  Med Biol Eng Comput       Date:  2019-10-10       Impact factor: 2.602

5.  A novel design framework of synthetic radial aperture focusing for volumetric transrectal ultrasound imaging.

Authors:  Hyunwoo Song; Jeeun Kang; Emad M Boctor
Journal:  J Comput Des Eng       Date:  2022-08-24

6.  Design of a Volumetric Imaging Sequence Using a Vantage-256 Ultrasound Research Platform Multiplexed With a 1024-Element Fully Sampled Matrix Array.

Authors:  Jaesok Yu; Heechul Yoon; Yousuf M Khalifa; Stanislav Y Emelianov
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-09-19       Impact factor: 2.725

7.  An Inventory of Current Available Ultrasound Devices for Dental Use.

Authors:  Le Tina; K M Aps Johan
Journal:  Open Dent J       Date:  2015-07-31

8.  Evaluation of Freehand B-Mode and Power-Mode 3D Ultrasound for Visualisation and Grading of Internal Carotid Artery Stenosis.

Authors:  Johann Otto Pelz; Anna Weinreich; Thomas Karlas; Dorothee Saur
Journal:  PLoS One       Date:  2017-01-03       Impact factor: 3.240

Review 9.  Use of ultrasound in image-guided high-dose-rate brachytherapy: enumerations and arguments.

Authors:  Susovan Banerjee; Tejinder Kataria; Deepak Gupta; Shikha Goyal; Shyam Singh Bisht; Trinanjan Basu; Ashu Abhishek
Journal:  J Contemp Brachytherapy       Date:  2017-04-27

10.  Navigation and visualisation with HoloLens in endovascular aortic repair.

Authors:  Verónica García-Vázquez; Felix von Haxthausen; Sonja Jäckle; Christian Schumann; Ivo Kuhlemann; Juljan Bouchagiar; Anna-Catharina Höfer; Florian Matysiak; Gereon Hüttmann; Jan Peter Goltz; Markus Kleemann; Floris Ernst; Marco Horn
Journal:  Innov Surg Sci       Date:  2018-10-04