Literature DB >> 32860091

Rapid identification and antimicrobial susceptibility testing of Gram-negative rod on positive blood cultures using MicroScan panels.

A Infante1, V Ortiz de la Tabla2, C Martín2, G Gázquez2, F Buñuel2.   

Abstract

Shortening the turnaround time of antimicrobial susceptibility testing (AST) of bacteria permits a significant reduction of patient morbidity, mortality, and cost. Conventional blood culture methods are the gold standard diagnostic test to guide management of patient with sepsis, but the conventional process requires at least 12 to 24 h after the blood culture has been flagged as positive due to requirement for pure colonies. We describe a simple and inexpensive method to obtain faster AST with MicroScan system (Beckman Coulter) directly from positive blood cultures. Conventional and direct identification and AST were performed simultaneously by both methods in 1070 blood cultures, and 9106 MICs were determinated. About 96.5% were correctly identified with the direct method. Overall, categorical agreement was 92.86%. We found 46 very major errors, but globally the results showed a good correlation with the standard method, particularly favorable for E. coli and K. pneumoniae, except amoxicillin-clavulanate and piperacillin-tazobactam. For P. mirabilis, betalactams antibiotics (except second- and third-generation cephalosporines) showed a good correlation, and also a good correlation was found for ciprofloxacine and gentamicine in P. aeruginosa and amoxicillin-clavulanate, ciprofloxacine, gentamicine, and cotrimoxazole in E. cloacae. This method has the main advantage of providing reliable results 1 day earlier, being a simple, fast, and cheap method for identification and antimicrobial susceptibility testing results from positive blood cultures.

Entities:  

Keywords:  Antimicrobial susceptibility testing; Directly from blood cultures; Gram-negative rods

Mesh:

Substances:

Year:  2020        PMID: 32860091     DOI: 10.1007/s10096-020-04014-3

Source DB:  PubMed          Journal:  Eur J Clin Microbiol Infect Dis        ISSN: 0934-9723            Impact factor:   3.267


  13 in total

1.  Direct susceptibility testing of positive blood cultures by using Sensititre broth microdilution plates.

Authors:  Kimberle C Chapin; Michael C Musgnug
Journal:  J Clin Microbiol       Date:  2003-10       Impact factor: 5.948

2.  Use of the BD PHOENIX Automated Microbiology System for direct identification and susceptibility testing of gram-negative rods from positive blood cultures in a three-phase trial.

Authors:  Guido Funke; Pascale Funke-Kissling
Journal:  J Clin Microbiol       Date:  2004-04       Impact factor: 5.948

3.  Direct susceptibility testing with positive BacT/Alert blood cultures by using MicroScan overnight and rapid panels.

Authors:  K B Waites; E S Brookings; S A Moser; B L Zimmer
Journal:  J Clin Microbiol       Date:  1998-07       Impact factor: 5.948

4.  Preliminary readings of antimicrobial susceptibility panels: A simple, fast and inexpensive way to detect bacterial resistance and enhance antibiotic treatment of bloodstream infections.

Authors:  Waldo Sánchez Yebra; Alexandre Xabier Obelleiro Campos; Laura Del Gigia Aguirre; Teresa Cabezas Fernández; Juan Sánchez Gómez; Cristina de Lamo Sevilla; José Gutiérrez Fernández; Manuel Rodríguez Maresca
Journal:  Diagn Microbiol Infect Dis       Date:  2019-03-07       Impact factor: 2.803

Review 5.  Emerging methodologies for pathogen identification in bloodstream infections: an update.

Authors:  Grégory Dubourg; Didier Raoult; Florence Fenollar
Journal:  Expert Rev Mol Diagn       Date:  2019-01-21       Impact factor: 5.225

6.  Rapid antimicrobial susceptibility testing by VITEK®2 directly from blood cultures in patients with Gram-negative rod bacteremia.

Authors:  C A Hogan; N Watz; I Budvytiene; N Banaei
Journal:  Diagn Microbiol Infect Dis       Date:  2019-01-16       Impact factor: 2.803

7.  The Slow March toward Rapid Phenotypic Antimicrobial Susceptibility Testing: Are We There Yet?

Authors:  Christopher D Doern
Journal:  J Clin Microbiol       Date:  2018-03-26       Impact factor: 5.948

8.  Performance of VITEK-2 Compact and overnight MicroScan panels for direct identification and susceptibility testing of Gram-negative bacilli from positive FAN BacT/ALERT blood culture bottles.

Authors:  M D Quesada; M Giménez; S Molinos; G Fernández; M D Sánchez; R Rivelo; A Ramírez; G Banqué; V Ausina
Journal:  Clin Microbiol Infect       Date:  2009-09-23       Impact factor: 8.067

9.  Rapid identification and antimicrobial susceptibility testing reduce antibiotic use and accelerate pathogen-directed antibiotic use.

Authors:  J J Kerremans; P Verboom; T Stijnen; L Hakkaart-van Roijen; W Goessens; H A Verbrugh; M C Vos
Journal:  J Antimicrob Chemother       Date:  2007-12-21       Impact factor: 5.790

10.  Identification and susceptibility testing of Enterobacteriaceae and Pseudomonas aeruginosa by direct inoculation from positive BACTEC blood culture bottles into Vitek 2.

Authors:  Marjan J Bruins; Peter Bloembergen; Gijs J H M Ruijs; Maurice J H M Wolfhagen
Journal:  J Clin Microbiol       Date:  2004-01       Impact factor: 5.948

View more
  1 in total

1.  Performance evaluation of the FAST™ System and the FAST-PBC Prep™ cartridges for speeded-up positive blood culture testing.

Authors:  Alexia Verroken; Chaima Hajji; Florian Bressant; Jonathan Couvreur; Ahalieyah Anantharajah; Hector Rodriguez-Villalobos
Journal:  Front Microbiol       Date:  2022-09-15       Impact factor: 6.064

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.