Literature DB >> 15070990

Use of the BD PHOENIX Automated Microbiology System for direct identification and susceptibility testing of gram-negative rods from positive blood cultures in a three-phase trial.

Guido Funke1, Pascale Funke-Kissling.   

Abstract

The present study describes the use of the automated BACTEC 9240 blood culture system, the Serum Separator Tube (SST), and the BD PHOENIX Automated Microbiology System in combination for the direct identification and antimicrobial susceptibility testing (AST) of gram-negative rods (GNRs) from positive blood cultures (BCs) without subculture. The study was conducted in three phases: (i) the recovery yield of Escherichia coli ATCC 25922 was determined with the SST between 0 and 8 h after spiked BC bottles turned positive; (ii) the identifications and susceptibility testing results obtained with the PHOENIX system for nine American Type Culture Collection strains of GNRs processed by the SST procedure and for colonies from agar medium were compared; and (iii) the procedure with the BACTEC system, SSTs, and the PHOENIX system was applied to positive cultures of blood from 309 patients during a 3-month period. The SST procedure with E. coli yielded sufficient numbers of cells to perform direct inoculation at any time between 0 and 8 h after a BC bottle turned positive. By using the identities obtained from pure cultures with the PHOENIX system and other biochemical identification systems as reference methods, the agreement between the reference methods and the PHOENIX system tested directly by using cultures of blood from patients was 92.9%. The 7.1% discrepant results were due to 6.5% incorrect identifications with the PHOENIX system with BC samples and 0.6% incorrect identifications with the PHOENIX system with samples from agar cultures. By AST the overall categorical accuracy was 99.0%, with 0.1% very major errors, 0.1% major errors, and 0.8% minor errors. In conclusion, use of the combination of the BACTEC system, SSTs, and the PHOENIX system has the potential to allow the agar isolation step to be skipped and the procedures for rapid direct identification and susceptibility testing of GNRs from positive BCs to be improved both in hospital-based and in central non-hospital-based laboratories.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15070990      PMCID: PMC387624          DOI: 10.1128/JCM.42.4.1466-1470.2004

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  11 in total

1.  Evaluation of wider system for direct identification and antimicrobial susceptibility testing of gram-negative bacilli from positive blood culture bottles.

Authors:  D Fontanals; F Salceda; J Hernández; I Sanfeliu; M Torra
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2002-09-10       Impact factor: 3.267

2.  Evaluation of the BD Phoenix automated identification and susceptibility testing system in clinical microbiology laboratory practice.

Authors:  E Stefaniuk; A Baraniak; M Gniadkowski; W Hryniewicz
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2003-07-18       Impact factor: 3.267

3.  Evaluation of the VITEK 2 system for rapid direct identification and susceptibility testing of gram-negative bacilli from positive blood cultures.

Authors:  Thomas K W Ling; Z K Liu; Augustine F B Cheng
Journal:  J Clin Microbiol       Date:  2003-10       Impact factor: 5.948

4.  Direct bacterial identification from positive BacT/Alert blood cultures using MicroScan overnight and rapid panels.

Authors:  K B Waites; E S Brookings; S A Moser; B L Zimmer
Journal:  Diagn Microbiol Infect Dis       Date:  1998-09       Impact factor: 2.803

5.  Direct susceptibility testing with positive BacT/Alert blood cultures by using MicroScan overnight and rapid panels.

Authors:  K B Waites; E S Brookings; S A Moser; B L Zimmer
Journal:  J Clin Microbiol       Date:  1998-07       Impact factor: 5.948

6.  Accuracy of the Vitek system for antimicrobial susceptibility testing Enterobacteriaceae bloodstream infection isolates: use of "direct" inoculation from Bactec 9240 blood culture bottles.

Authors:  L R Putnam; W J Howard; M A Pfaller; F P Koontz; R N Jones
Journal:  Diagn Microbiol Infect Dis       Date:  1997-06       Impact factor: 2.803

7.  Direct identification and susceptibility testing of enteric bacilli from positive blood cultures using VITEK (GNI+/GNS-GA).

Authors:  D S Hansen; A G Jensen; N Nørskov-Lauritsen; R Skov; B Bruun
Journal:  Clin Microbiol Infect       Date:  2002-01       Impact factor: 8.067

8.  Clinical and financial benefits of rapid bacterial identification and antimicrobial susceptibility testing.

Authors:  J Barenfanger; C Drake; G Kacich
Journal:  J Clin Microbiol       Date:  1999-05       Impact factor: 5.948

9.  Clinical impact of rapid identification and susceptibility testing of bacterial blood culture isolates.

Authors:  G M Trenholme; R L Kaplan; P H Karakusis; T Stine; J Fuhrer; W Landau; S Levin
Journal:  J Clin Microbiol       Date:  1989-06       Impact factor: 5.948

10.  Clinical impact of rapid in vitro susceptibility testing and bacterial identification.

Authors:  G V Doern; R Vautour; M Gaudet; B Levy
Journal:  J Clin Microbiol       Date:  1994-07       Impact factor: 5.948

View more
  27 in total

1.  Strategy for rapid identification and antibiotic susceptibility testing of gram-negative bacteria directly recovered from positive blood cultures using the Bruker MALDI Biotyper and the BD Phoenix system.

Authors:  Jana L Wimmer; S Wesley Long; Patricia Cernoch; Geoffrey A Land; James R Davis; James M Musser; Randall J Olsen
Journal:  J Clin Microbiol       Date:  2012-04-18       Impact factor: 5.948

2.  Two-center collaborative evaluation of performance of the BD phoenix automated microbiology system for identification and antimicrobial susceptibility testing of gram-negative bacteria.

Authors:  Maria Grazia Menozzi; Ulrich Eigner; Silvia Covan; Sabina Rossi; Pietro Somenzi; Giuseppe Dettori; Carlo Chezzi; Anne-Marie Fahr
Journal:  J Clin Microbiol       Date:  2006-09-27       Impact factor: 5.948

3.  Accuracies of beta-lactam susceptibility test results for Pseudomonas aeruginosa with four automated systems (BD Phoenix, MicroScan WalkAway, Vitek, and Vitek 2).

Authors:  Stefan Juretschko; Vincent J Labombardi; Stephen A Lerner; Paul C Schreckenberger
Journal:  J Clin Microbiol       Date:  2007-01-17       Impact factor: 5.948

4.  Evaluation of the Merlin MICRONAUT system for rapid direct susceptibility testing of gram-positive cocci and gram-negative bacilli from positive blood cultures.

Authors:  Nele Wellinghausen; Tim Pietzcker; Sven Poppert; Syron Belak; Nicole Fieser; Melanie Bartel; Andreas Essig
Journal:  J Clin Microbiol       Date:  2007-01-03       Impact factor: 5.948

5.  Isolation of Pseudomonas aeruginosa from open ocean and comparison with freshwater, clinical, and animal isolates.

Authors:  Nurul Huda Khan; Yoshikazu Ishii; Noriko Kimata-Kino; Hidetake Esaki; Tomohiko Nishino; Masahiko Nishimura; Kazuhiro Kogure
Journal:  Microb Ecol       Date:  2007-02       Impact factor: 4.552

6.  Phoenix 100 versus Vitek 2 in the identification of gram-positive and gram-negative bacteria: a comprehensive meta-analysis.

Authors:  Kalliopi-Stavroula Chatzigeorgiou; Theodoros N Sergentanis; Sotirios Tsiodras; Stavros J Hamodrakas; Pantelis G Bagos
Journal:  J Clin Microbiol       Date:  2011-07-13       Impact factor: 5.948

7.  Novel, improved sample preparation for rapid, direct identification from positive blood cultures using matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry.

Authors:  Sören Schubert; Kirsten Weinert; Chris Wagner; Beatrix Gunzl; Andreas Wieser; Thomas Maier; Markus Kostrzewa
Journal:  J Mol Diagn       Date:  2011-09-01       Impact factor: 5.568

8.  Rapid identification and antimicrobial susceptibility testing of Gram-negative rod on positive blood cultures using MicroScan panels.

Authors:  A Infante; V Ortiz de la Tabla; C Martín; G Gázquez; F Buñuel
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2020-08-29       Impact factor: 3.267

9.  Direct identification of bacteria in positive blood culture bottles by matrix-assisted laser desorption ionisation time-of-flight mass spectrometry.

Authors:  Bernard La Scola; Didier Raoult
Journal:  PLoS One       Date:  2009-11-25       Impact factor: 3.240

10.  Rapid identification and antimicrobial susceptibility profiling of Gram-positive cocci in blood cultures with the Vitek 2 system.

Authors:  A Lupetti; S Barnini; B Castagna; A-L Capria; P H Nibbering
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2009-11-10       Impact factor: 3.267

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.