Literature DB >> 19778301

Performance of VITEK-2 Compact and overnight MicroScan panels for direct identification and susceptibility testing of Gram-negative bacilli from positive FAN BacT/ALERT blood culture bottles.

M D Quesada1, M Giménez, S Molinos, G Fernández, M D Sánchez, R Rivelo, A Ramírez, G Banqué, V Ausina.   

Abstract

We describe the reliability of the VITEK-2 Compact and overnight MicroScan panels for direct identification and susceptibility testing from the BacT/ALERT blood culture system when using FAN (FA and FN) bottles. A simple procedure, in two centrifugation steps, was designed to remove the charcoal particles present in FA and FN bottles. A total of 113 positive blood cultures showing Gram-negative rods were investigated. Enterobacteriaceae were isolated in 104 cases, and Pseudomonas aeruginosa in nine. The MicroScan system correctly identified 106 (93.8%) of the 113 isolates. The seven identificaction errors included P. aeruginosa (three), Enterobacter cloacae (one), Escherichia coli (one), Klebsiella oxytoca (one), and Klebsiella pneumoniae (one). The VITEK-2 system correctly identified 109 (96.5%) of the 113 samples obtained directly from the blood culture bottles. The four unidentified isolates were Enterobacter cloacae (two), Escherichia coli (one), and P. aeruginosa (one). MicroScan yielded 4/779 (0.5%) very major errors and 28/2825 (0.9%) minor errors. VITEK-2 yielded 2/550 (0.36%) very major errors, 1/1718 (0.05%) major error, and 32/2373 (1.3%) minor errors. Both systems provided excellent identification (correlation of >90%) and susceptibility (correlation of >98%) results. The average times required to obtain identification and susceptibility results using the direct test applied to the VITEK-2 Compact system were 4.57 +/- 1.37 h and 6.52 +/- 1.64 h, respectively. The VITEK-2 compact system provided results on the same day that the blood culture was found to be positive.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19778301     DOI: 10.1111/j.1469-0691.2009.02907.x

Source DB:  PubMed          Journal:  Clin Microbiol Infect        ISSN: 1198-743X            Impact factor:   8.067


  11 in total

1.  Comparative evaluation of Vitek 2 identification and susceptibility testing of Gram-negative rods directly and isolated from BacT/ALERT-positive blood culture bottles.

Authors:  M J Munoz-Dávila; G Yagüe; M Albert; T García-Lucas
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2011-07-28       Impact factor: 3.267

2.  Comparative evaluation of Vitek 2 identification and susceptibility testing of urinary tract pathogens directly and isolated from chromogenic media.

Authors:  M J Munoz-Dávila; M Roig; G Yagüe; A Blázquez; C Salvador; M Segovia
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2013-01-12       Impact factor: 3.267

3.  International dissemination of Escherichia coli strains with discrepant behaviour in phenotypic antimicrobial susceptibility tests.

Authors:  D Creely; G Zambardi; A van Belkum; Wm M Dunne; M Peyret; J P Gayral; D Shortridge; C Shubert
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2013-02-09       Impact factor: 3.267

4.  Comparison of meropenem MICs and susceptibilities for carbapenemase-producing Klebsiella pneumoniae isolates by various testing methods.

Authors:  Catharine C Bulik; Kathy A Fauntleroy; Stephen G Jenkins; Mayssa Abuali; Vincent J LaBombardi; David P Nicolau; Joseph L Kuti
Journal:  J Clin Microbiol       Date:  2010-05-19       Impact factor: 5.948

5.  Acceleration of antimicrobial susceptibility testing of positive blood cultures by inoculation of Vitek 2 cards with briefly incubated solid medium cultures.

Authors:  Evgeny A Idelevich; Isabel Schüle; Barbara Grünastel; Jörg Wüllenweber; Georg Peters; Karsten Becker
Journal:  J Clin Microbiol       Date:  2014-08-27       Impact factor: 5.948

6.  Rapid identification and antimicrobial susceptibility testing of Gram-negative rod on positive blood cultures using MicroScan panels.

Authors:  A Infante; V Ortiz de la Tabla; C Martín; G Gázquez; F Buñuel
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2020-08-29       Impact factor: 3.267

7.  Direct antimicrobial susceptibility testing from positive blood culture bottles in laboratories lacking automated antimicrobial susceptibility testing systems.

Authors:  Mahadevan Kumar; S P S Shergill; Kundan Tandel; Kavita Sahai; R M Gupta
Journal:  Med J Armed Forces India       Date:  2018-12-20

8.  Rapid diagnosis of bloodstream infections with PCR followed by mass spectrometry.

Authors:  Elena Jordana-Lluch; Heather E Carolan; Montserrat Giménez; Rangarajan Sampath; David J Ecker; M Dolores Quesada; Josep M Mòdol; Fernando Arméstar; Lawrence B Blyn; Lendell L Cummins; Vicente Ausina; Elisa Martró
Journal:  PLoS One       Date:  2013-04-23       Impact factor: 3.240

9.  Evaluation of the Broad-Range PCR/ESI-MS Technology in Blood Specimens for the Molecular Diagnosis of Bloodstream Infections.

Authors:  Elena Jordana-Lluch; Montserrat Giménez; M Dolores Quesada; Belén Rivaya; Clara Marcó; M Jesús Domínguez; Fernando Arméstar; Elisa Martró; Vicente Ausina
Journal:  PLoS One       Date:  2015-10-16       Impact factor: 3.240

10.  The Emerging Resistance in Nosocomial Urinary Tract Infections: From the Pediatrics Perspective.

Authors:  Fatma Devrim; Erkin Serdaroğlu; İlknur Çağlar; Yeliz Oruç; Nevbahar Demiray; Nuri Bayram; Hasan Ağın; Sebnem Çalkavur; Yelda Sorguç; Nida Dinçel; Yüce Ayhan; Ebru Yılmaz; Ilker Devrim
Journal:  Mediterr J Hematol Infect Dis       Date:  2018-09-01       Impact factor: 2.576