Literature DB >> 14715724

Identification and susceptibility testing of Enterobacteriaceae and Pseudomonas aeruginosa by direct inoculation from positive BACTEC blood culture bottles into Vitek 2.

Marjan J Bruins1, Peter Bloembergen, Gijs J H M Ruijs, Maurice J H M Wolfhagen.   

Abstract

Inoculation of an automated system for rapid identification (ID) and antimicrobial susceptibility testing (AST) directly from positive blood culture bottles will reduce the turnaround time of laboratory diagnosis of septicemic patients, which benefits clinical outcome and decreases patient costs. Direct test results, however, must always be confirmed by testing a pure overnight culture, which is the "gold standard." We studied the accuracy of direct testing versus repeat testing in order to investigate the possibility of refraining from repeat testing. We also assessed the clinical risk of reporting results based on direct testing only. We inoculated Vitek 2 (bioMérieux) directly from 410 positive BACTEC 9240 (BD) blood culture bottles containing gram-negative rods and studied the ID and AST results. In a comparison of direct inoculation with the standard method, a total of 344 isolates of Enterobacteriaceae and Pseudomonas aeruginosa were tested, and 93.0% were correctly identified. Of the 39 (10.2%) samples that contained bacilli not identifiable by Vitek 2, only 1 gave a conclusive, correct result. The overall MIC agreement among 312 isolates was 99.2%, with 0.8% very major and 0.02% major error rates. Of only three (polymicrobial) samples, the direct susceptibility pattern would be reported to the clinician as too sensitive. Vitek 2 results obtained from direct inoculation of blood culture bottles containing gram-negative bacilli are safe enough for immediate reporting, provided that ID and AST are consistent. Repeat testing is not necessary, unless Gram stain or overnight subculture results raise doubt about the purity of the culture.

Entities:  

Mesh:

Year:  2004        PMID: 14715724      PMCID: PMC321735          DOI: 10.1128/JCM.42.1.7-11.2004

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  19 in total

1.  Evaluation of VITEK 2 rapid identification and susceptibility testing system against gram-negative clinical isolates.

Authors:  T K Ling; P C Tam; Z K Liu; A F Cheng
Journal:  J Clin Microbiol       Date:  2001-08       Impact factor: 5.948

2.  Potential impact of the VITEK 2 system and the Advanced Expert System on the clinical laboratory of a university-based hospital.

Authors:  C C Sanders; M Peyret; E S Moland; S J Cavalieri; C Shubert; K S Thomson; J M Boeufgras; W E Sanders
Journal:  J Clin Microbiol       Date:  2001-07       Impact factor: 5.948

3.  Evaluation of the Vitek 2 system for rapid identification of clinical isolates of gram-negative bacilli and members of the family Streptococcaceae.

Authors:  P J Gavin; J R Warren; A A Obias; S M Collins; L R Peterson
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2002-12-10       Impact factor: 3.267

4.  Direct identification and susceptibility testing of enteric bacilli from positive blood cultures using VITEK (GNI+/GNS-GA).

Authors:  D S Hansen; A G Jensen; N Nørskov-Lauritsen; R Skov; B Bruun
Journal:  Clin Microbiol Infect       Date:  2002-01       Impact factor: 8.067

5.  Comparison of a highly automated 5-h susceptibility testing system, the Cobas-Bact, with two reference methods: Kirby-Bauer disk diffusion and broth microdilution.

Authors:  P R Murray; A C Niles; R L Heeren
Journal:  J Clin Microbiol       Date:  1987-12       Impact factor: 5.948

6.  Clinical and financial benefits of rapid bacterial identification and antimicrobial susceptibility testing.

Authors:  J Barenfanger; C Drake; G Kacich
Journal:  J Clin Microbiol       Date:  1999-05       Impact factor: 5.948

7.  Rapid identification and antimicrobial susceptibility testing of gram-negative bacilli from blood cultures by the AutoMicrobic system.

Authors:  D F Moore; S S Hamada; E Marso; W J Martin
Journal:  J Clin Microbiol       Date:  1981-05       Impact factor: 5.948

8.  Clinical impact of rapid identification and susceptibility testing of bacterial blood culture isolates.

Authors:  G M Trenholme; R L Kaplan; P H Karakusis; T Stine; J Fuhrer; W Landau; S Levin
Journal:  J Clin Microbiol       Date:  1989-06       Impact factor: 5.948

9.  Antimicrobial susceptibility and frequency of occurrence of clinical blood isolates in Europe from the SENTRY antimicrobial surveillance program, 1997 and 1998.

Authors:  A C Fluit; M E Jones; F J Schmitz; J Acar; R Gupta; J Verhoef
Journal:  Clin Infect Dis       Date:  2000-03       Impact factor: 9.079

10.  Evaluation of the Vitek 2 ID-GNB assay for identification of members of the family Enterobacteriaceae and other nonenteric gram-negative bacilli and comparison with the Vitek GNI+ card.

Authors:  Caroline M O'Hara; J Michael Miller
Journal:  J Clin Microbiol       Date:  2003-05       Impact factor: 5.948

View more
  32 in total

1.  Use of positive blood cultures for direct identification and susceptibility testing with the vitek 2 system.

Authors:  Marina de Cueto; Esther Ceballos; Luis Martinez-Martinez; Evelio J Perea; Alvaro Pascual
Journal:  J Clin Microbiol       Date:  2004-08       Impact factor: 5.948

2.  Strategy for rapid identification and antibiotic susceptibility testing of gram-negative bacteria directly recovered from positive blood cultures using the Bruker MALDI Biotyper and the BD Phoenix system.

Authors:  Jana L Wimmer; S Wesley Long; Patricia Cernoch; Geoffrey A Land; James R Davis; James M Musser; Randall J Olsen
Journal:  J Clin Microbiol       Date:  2012-04-18       Impact factor: 5.948

3.  Rapid identification of bacteria from positive blood culture bottles by use of matrix-assisted laser desorption-ionization time of flight mass spectrometry fingerprinting.

Authors:  Martin Christner; Holger Rohde; Manuel Wolters; Ingo Sobottka; Karl Wegscheider; Martin Aepfelbacher
Journal:  J Clin Microbiol       Date:  2010-03-17       Impact factor: 5.948

Review 4.  Manual and automated instrumentation for identification of Enterobacteriaceae and other aerobic gram-negative bacilli.

Authors:  Caroline M O'hara
Journal:  Clin Microbiol Rev       Date:  2005-01       Impact factor: 26.132

5.  Accuracy of identification and susceptibility results by direct inoculation of Vitek 2 cards from positive BACTEC cultures.

Authors:  J J Kerremans; W H F Goessens; H A Verbrugh; M C Vos
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2004-12       Impact factor: 3.267

6.  Evaluation of the Merlin MICRONAUT system for rapid direct susceptibility testing of gram-positive cocci and gram-negative bacilli from positive blood cultures.

Authors:  Nele Wellinghausen; Tim Pietzcker; Sven Poppert; Syron Belak; Nicole Fieser; Melanie Bartel; Andreas Essig
Journal:  J Clin Microbiol       Date:  2007-01-03       Impact factor: 5.948

7.  Comparative evaluation of Vitek 2 identification and susceptibility testing of Gram-negative rods directly and isolated from BacT/ALERT-positive blood culture bottles.

Authors:  M J Munoz-Dávila; G Yagüe; M Albert; T García-Lucas
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2011-07-28       Impact factor: 3.267

8.  Rapid identification and antimicrobial susceptibility testing of Gram-negative rod on positive blood cultures using MicroScan panels.

Authors:  A Infante; V Ortiz de la Tabla; C Martín; G Gázquez; F Buñuel
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2020-08-29       Impact factor: 3.267

9.  Evaluation of the Hyplex BloodScreen Multiplex PCR-Enzyme-linked immunosorbent assay system for direct identification of gram-positive cocci and gram-negative bacilli from positive blood cultures.

Authors:  Nele Wellinghausen; Beate Wirths; Andreas Essig; Lars Wassill
Journal:  J Clin Microbiol       Date:  2004-07       Impact factor: 5.948

10.  Rapid identification and antimicrobial susceptibility profiling of Gram-positive cocci in blood cultures with the Vitek 2 system.

Authors:  A Lupetti; S Barnini; B Castagna; A-L Capria; P H Nibbering
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2009-11-10       Impact factor: 3.267

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.