This study evaluated the shielding effect of a newly developed dose-reduction fiber (DRF) made from barium sulfate, in terms of radiation doses delivered to patients' radiosensitive organs and operator during C-arm fluoroscopy and its impact on the quality of images. A C-arm fluoroscopy unit was placed beside a whole-body phantom. Radiophotoluminescent glass dosimeters were attached to the back and front of the whole-body phantom at 20 cm intervals. Radiation doses were measured without DRF and with it applied to the back (position 1), front (position 2) or both sides (position 3) of the phantom. To investigate the impact of DRF on the quality of fluoroscopic images, step-wedge and modulation transfer function phantoms were used. The absorbed radiation doses to the back of the phantom significantly decreased by 25.3-88.8% after applying DRF to positions 1 and 3. The absorbed radiation doses to the front of the phantom significantly decreased by 55.3-93.6% after applying DRF to positions 2 and 3. The contrast resolution values for each adjacent step area fell in the range 0.0119-0.0209, 0.0128-0.0271, 0.0135-0.0339 and 0.0152-0.0339 without and with DRF applied to positions 1, 2 and 3, respectively. The investigated DRF effectively reduces absorbed radiation doses to patients and operators without decreasing the quality of C-arm fluoroscopic images. Therefore, routine clinical use of the DRF is recommended during the use of C-arm fluoroscopy.
© The Author(s) 2020. Published by Oxford University Press on behalf of The Japanese Radiation Research Society and Japanese Society for Radiation Oncology.

Entities:  

Keywords:  C-arm fluoroscopy; barium sulfate; dose reduction fiber; radiation dose

Mesh:

Substances:

Year:  2020        PMID: 32766722      PMCID: PMC7482166          DOI: 10.1093/jrr/rraa060

Source DB:  PubMed          Journal:  J Radiat Res        ISSN: 0449-3060            Impact factor:   2.724


  24 in total

1.  ICRP Publication 117. Radiological protection in fluoroscopically guided procedures performed outside the imaging department.

Authors:  M M Rehani; O Ciraj-Bjelac; E Vañó; D L Miller; S Walsh; B D Giordano; J Persliden
Journal:  Ann ICRP       Date:  2010-12

2.  Radiation dose reduction to breast and thyroid during MDCT: effectiveness of an in-plane bismuth shield.

Authors:  C Hohl; J E Wildberger; C Süss; C Thomas; G Mühlenbruch; T Schmidt; D Honnef; R W Günther; A H Mahnken
Journal:  Acta Radiol       Date:  2006-07       Impact factor: 1.990

Review 3.  Computed tomography--an increasing source of radiation exposure.

Authors:  David J Brenner; Eric J Hall
Journal:  N Engl J Med       Date:  2007-11-29       Impact factor: 91.245

4.  Types and arrangement of thyroid shields to reduce exposure of surgeons to ionizing radiation during intraoperative use of C-arm fluoroscopy.

Authors:  Seung Yeol Lee; Eungi Min; Jaekeon Bae; Chin Youb Chung; Kyoung Min Lee; Soon-Sun Kwon; Moon Seok Park; Kisung Lee
Journal:  Spine (Phila Pa 1976)       Date:  2013-11-15       Impact factor: 3.468

5.  Lightweight bilayer barium sulfate-bismuth oxide composite thyroid collars for superior radiation protection in fluoroscopy-guided interventions: a prospective randomized controlled trial.

Authors:  Heiko Uthoff; Matthew J Benenati; Barry T Katzen; Constantino Peña; Ripal Gandhi; Daniel Staub; Melanie Schernthaner
Journal:  Radiology       Date:  2013-10-28       Impact factor: 11.105

6.  A study on the radiation dose of the orthopaedic surgeon and staff from a mini C-arm fluoroscopy unit.

Authors:  Asghar Mesbahi; Alireza Rouhani
Journal:  Radiat Prot Dosimetry       Date:  2008-09-02       Impact factor: 0.972

7.  A phantom-based evaluation of three commercially available patient organ shields for computed tomography X-ray examinations in diagnostic radiology.

Authors:  Jamie Huggett; William Mukonoweshuro; Robert Loader
Journal:  Radiat Prot Dosimetry       Date:  2012-12-05       Impact factor: 0.972

Review 8.  Use of bismuth shield for protection of superficial radiosensitive organs in patients undergoing computed tomography: a literature review and meta-analysis.

Authors:  Parinaz Mehnati; Reza Malekzadeh; Mohammad Yousefi Sooteh
Journal:  Radiol Phys Technol       Date:  2019-02-21

9.  Computed tomography scanning in pediatric trauma: opportunities for performance improvement and radiation safety.

Authors:  Charles W Hartin; Jeffery M Jordan; Seth Gemme; Philip L Glick; Michael G Caty; Doruk E Ozgediz; Kathryn D Bass
Journal:  J Surg Res       Date:  2012-04-28       Impact factor: 2.192

10.  Physical analysis of the shielding capacity for a lightweight apron designed for shielding low intensity scattering X-rays.

Authors:  Seon Chil Kim; Jeong Ryeol Choi; Byeong Kyou Jeon
Journal:  Sci Rep       Date:  2016-07-27       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.