| Literature DB >> 32742091 |
Giulia Baccaglione1, Elisa Rota2, Maurizio Ferrari2, Marcello Maddalone1.
Abstract
AIM: The purpose of this research is to analyze and compare the dental and skeletal changes induced by two functional devices, Andreasen Activator and Clark's twin block, on the sagittal and vertical plane, by means of cephalometric analysis, of the lateral cephalograms prescribed at the beginning and at the end of the treatment for a second skeletal class, first division with normal or deep bite.Entities:
Keywords: Andreasen activator; Cephalometrics; II class; Malocclusion; Mandible; Prospective longitudinal clinical study; Twin block
Year: 2020 PMID: 32742091 PMCID: PMC7366767 DOI: 10.5005/jp-journals-10005-1725
Source DB: PubMed Journal: Int J Clin Pediatr Dent ISSN: 0974-7052
Results of the statistical analysis with paired t-test on cephalometric values of patients treated with Andreasen activator
| SNA (°) | 82.0 | 1.080 | 81.8 | 1.099 | −0.2 | 0.8618 | NS |
| SNB (°) | 77.2 | 1.398 | 79.3 | 1.229 | 2.1 | 0.0006 | |
| ANB (°) | 4.8 | 1.418 | 2.5 | 0.8165 | −2.3 | 0.0016 | |
| SnaSnp–GoGn (°) | 19.6 | 3.026 | 22.2 | 3.048 | 2.6 | <0.0001 | |
| Sna–Snp (mm) | 49.7 | 2.83 | 51.8 | 3.521 | 2.1 | 0.0713 | NS |
| Co–Gn (mm) | 102.8 | 3.457 | 108.3 | 6.037 | 5.5 | 0.0016 | |
| Co–Go (mm) | 53.2 | 3.190 | 56.7 | 4.595 | 3.5 | 0.0049 | |
| Go–Gn (mm) | 66.8 | 3.823 | 70.7 | 5.417 | 3.9 | 0.0342 | |
| U1/SnaSnp (°) | 115.3 | 5.314 | 114.9 | 6.574 | −0.4 | 0.7473 | NS |
| L1/GoGn (°) | 100.1 | 4.533 | 99.7 | 3.622 | −0.4 | 0.6476 | NS |
| Ovj (mm) | 4.7 | 1.16 | 3.1 | 1.287 | −1.6 | 0.0133 | |
| Ovb (mm) | 4.3 | 1.398 | 2.7 | 0.948 | −1.6 | 0.0046 | |
p < 0.05;
p < 0.01;
p < 0.001;
p < 0.0001;
NS, not significant
Results of the statistical analysis with paired t-test on cephalometric values of patients treated with twin block appliance
| SNA (°) | 81.2 | 1.65 | 81 | 1.247 | −0.2 | 0.0522 | NS |
| SNB (°) | 76.2 | 2.058 | 78.5 | 1.814 | 2.3 | <0.0001 | |
| ANB (°) | 5.1 | 0.9189 | 2.5 | 0.7888 | −2.6 | <0.0001 | |
| SnaSnp–GoGn (°) | 21.1 | 2.079 | 23.1 | 2.331 | 2 | 0.0002 | |
| Sna–Snp (mm) | 52.2 | 2.201 | 53.9 | 1.269 | 1.7 | 0.0526 | NS |
| Co–Gn (mm) | 102.3 | 2.983 | 108.2 | 3.706 | 5.9 | 0.0002 | |
| Co–Go (mm) | 50.7 | 3.268 | 55 | 3.916 | 4.3 | 0.0016 | |
| Go–Gn (mm) | 65.9 | 3.348 | 69.6 | 4.858 | 3.7 | 0.0132 | |
| U1/SnaSnp (°) | 116.1 | 3.414 | 112.4 | 2.875 | −3.7 | 0.0078 | |
| L1/GoGn (°) | 99.2 | 2.098 | 100.4 | 2.633 | 1.2 | 0.3009 | NS |
| Ovj (mm) | 6.2 | 2.3 | 3.5 | 0.971 | −2.7 | 0.0039 | |
| Ovb (mm) | 4.7 | 2.111 | 2.9 | 0.994 | −1.8 | 0.0120 | |
p < 0.05;
p < 0.01;
p < 0.001;
p < 0.0001;
NS, not significant
Comparison in the results of the statistical analysis with unpaired t-test on cephalometric values of patients treated with Andreasen activator and twin block appliance
| SNA (°) | −0.2 ± 0.4422 | −0.2 ± 0.2236 | 0 ± 0.4955 | 0.9551 | NS |
| SNB (°) | 2.1 ± 0.4069 | 2.3 ± 0.2333 | 0.2 ± 0.469 | 0.6999 | NS |
| ANB (°) | −2.3 ± 0.5175 | −2.6 ± 0.1633 | 0.3 ± 0.5426 | 0.5916 | NS |
| SnaSnp–GoGn (°) | 2.6 ± 0.3712 | 2 ± 0.3333 | −0.6 ± 0.4989 | 0.2449 | NS |
| Sna–Snp (mm) | 2.1 ± 0.9597 | 1.7 ± 0.5588 | −0.4 ± 1.111 | 0.4828 | NS |
| Co–Gn (mm) | 5.5 ± 1.241 | 5.9 ± 0.9826 | 0.4 ± 1.583 | 0.8035 | NS |
| Co–Go (mm) | 4.5 ± 0.9458 | 4.3 ± 0.9667 | −0.2 ± 1.352 | 0.5615 | NS |
| Go–Gn (mm) | 3.9 ± 0.7951 | 3.7 ± 1.202 | −0.2 ± 1.91 | 0.8914 | NS |
| U1/SnaSnp (°) | −0.7 ± 1.126 | −3.7 ± 1.086 | −3 ± 1.564 | 0.0711 | NS |
| L1/GoGn (°) | −0.4 ± 0.8459 | 1.2 ± 1.093 | 1.6 ± 1.382 | 0.2632 | NS |
| Ovj (mm) | −1.6 ± 0.5207 | −2.7 ± 0.7 | −1.1 ± 0.8724 | 0.2248 | NS |
| Ovb (mm) | −1.6 ± 0.5164 | −1.8 ± 0.5735 | −0.2 ± 0.7717 | 0.3138 | NS |
NS, not significant