A depth-encoding PET detector for high resolution PET using 1 mm SiPMs.

Junwei Du1, Xiaowei Bai, Simon R Cherry.   

Abstract

A dual-ended readout PET detector based on two Hamamatsu 16 × 16 arrays of 1 × 1 mm2 SiPMs coupled to both ends of a 25 × 25 array of 0.69 × 0.69 × 20 mm3 polished LYSOs was evaluated in terms of flood histogram, energy resolution, timing resolution, and DOI resolution. The SiPM arrays have a pitch size of 1.2 mm. Each SiPM pixel has an active area of 1 × 1 mm2, and was fabricated using 15 μm microcells. The LYSO array has a pitch size of 0.75 mm, and the crystals are separated using Toray reflector with a thickness of 50 μm. The flood histogram and energy resolution were measured at different overvoltages (ranging from 1.5 to 7.0 V, in 0.5 V steps) and at four different temperatures (-7, 0, 10 and 20 °C). The timing resolution and DOI resolution were obtained at the optimal overvoltage for the flood histogram and at each different temperature. Overall, the results show better performance was obtained at lower temperatures, and that the optimal overvoltage decreased at higher temperatures. The optimal overvoltage was 5.0 V (corresponding to a bias voltage of 68.5 V) in order to achieve the highest quality flood histogram at 0 °C. Under these conditions, the flood histogram quality, energy resolution, timing resolution, and DOI resolution were 3.26 ± 0.65, 18.4 ± 4.5%, 1.70 ± 0.12 ns and 2.22 ± 0.19 mm, respectively. The flood histograms and energy resolution were also obtained at different activities. The results show that better flood histogram and energy resolution were obtained at lower activity, however all the crystals can be resolved at an event rate of over 210 k cps, indicating the DOI detector module can be used both for high resolution human brain PET and small animal PET applications.

Entities:  

Mesh:

Substances:

Year:  2020        PMID: 32580180      PMCID: PMC8665693          DOI: 10.1088/1361-6560/ab9fc9

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  26 in total

1.  Depth of interaction calibration for PET detectors with dual-ended readout by PSAPDs.

Authors:  Yongfeng Yang; Jinyi Qi; Yibao Wu; Sara St James; Richard Farrell; Purushottam A Dokhale; Kanai S Shah; Simon R Cherry
Journal:  Phys Med Biol       Date:  2008-12-19       Impact factor: 3.609

2.  Design and evaluation of gapless curved scintillator arrays for simultaneous high-resolution and high-sensitivity brain PET.

Authors:  Junwei Du; Xiaowei Bai; Chih-Chieh Liu; Jinyi Qi; Simon R Cherry
Journal:  Phys Med Biol       Date:  2019-11-26       Impact factor: 3.609

3.  Characterisation of partial volume effect and region-based correction in small animal positron emission tomography (PET) of the rat brain.

Authors:  Wencke Lehnert; Marie-Claude Gregoire; Anthonin Reilhac; Steven R Meikle
Journal:  Neuroimage       Date:  2012-02-22       Impact factor: 6.556

4.  Simulation study of spatial resolution and sensitivity for the tapered depth of interaction PET detectors for small animal imaging.

Authors:  Sara St James; Yongfeng Yang; Spencer L Bowen; Jinyi Qi; Simon R Cherry
Journal:  Phys Med Biol       Date:  2009-12-21       Impact factor: 3.609

5.  Performance Simulation of an Ultra-High Resolution Brain PET Scanner Using 1.2-mm Pixel Detectors.

Authors:  Émilie Gaudin; Maxime Toussaint; Christian Thibaudeau; Maxime Paillé; Réjean Fontaine; Roger Lecomte
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2018-10-23

6.  Development of a prototype PET scanner with depth-of-interaction measurement using solid-state photomultiplier arrays and parallel readout electronics.

Authors:  Yiping Shao; Xishan Sun; Kejian A Lan; Chad Bircher; Kai Lou; Zhi Deng
Journal:  Phys Med Biol       Date:  2014-02-20       Impact factor: 3.609

Review 7.  Nuclear imaging of neuroinflammation: a comprehensive review of [11C]PK11195 challengers.

Authors:  Fabien Chauveau; Hervé Boutin; Nadja Van Camp; Frédéric Dollé; Bertrand Tavitian
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-10-01       Impact factor: 9.236

8.  Characterization of Large-Area SiPM Array for PET Applications.

Authors:  Junwei Du; Yongfeng Yang; Xiaowei Bai; Martin S Judenhofer; Eric Berg; Kun Di; Steve Buckley; Carl Jackson; Simon R Cherry
Journal:  IEEE Trans Nucl Sci       Date:  2016-02-15       Impact factor: 1.679

9.  Small animal PET imaging.

Authors:  Gary D Hutchins; Michael A Miller; Victor C Soon; Timothy Receveur
Journal:  ILAR J       Date:  2008

10.  A study of the timing properties of position-sensitive avalanche photodiodes.

Authors:  Yibao Wu; Thomas S C Ng; Yongfeng Yang; Kanai Shah; Richard Farrell; Simon R Cherry
Journal:  Phys Med Biol       Date:  2009-08-11       Impact factor: 3.609

View more
  2 in total

1.  A high resolution and high detection efficiency depth-encoding detector for brain positron emission tomography based on a 0.75 mm pitch scintillator array.

Authors:  J Du; S R Cherry
Journal:  J Instrum       Date:  2021-05-20       Impact factor: 1.415

2.  H2RSPET: a 0.5 mm resolution high-sensitivity small-animal PET scanner, a simulation study.

Authors:  Youfang Lai; Qian Wang; Shiwei Zhou; Zhaoheng Xie; Jinyi Qi; Simon R Cherry; Mingwu Jin; Yujie Chi; Junwei Du
Journal:  Phys Med Biol       Date:  2021-03-09       Impact factor: 3.609

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.